Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 15 min ago
Peer-reviewedCC BY-NC-NDBMC nursing

Effect of a mobile-based cognitive simulator (Touch Surgery) on knowledge, simulated scrub-role performance, and perceived perioperative competence among operating room technology students: a randomized controlled trial.

  1. 1Department of Operating Room, School of Allied Medical Sciences, Iran University of Medical Sciences, Tehran, Iran.
  2. 2Department of Operating Room, School of Allied Medical Sciences, Birjand University of Medical Sciences, Birjand, Iran.
  3. 3Laboratory Sciences Research Center, Department of Surgical Technology, Faculty of Paramedical Sciences, Golestan University of Medical Sciences, Gorgan, Iran. [email protected].

Abstract

Background

Surgical training is confronted with structural limitations, which have prompted worldwide movement towards mobile cognitive simulators. The aim of the current study was to investigate the effect of the use of the Touch Surgery simulator on knowledge of surgical procedures, clinical practice skills, perceived competence, and safety attitudes in operating room technology students performing laparoscopic cholecystectomy.Methods

A two-group parallel randomized controlled trial with repeated measurements was adopted in the study with 80 OR technology undergraduates allocated to the experimental group (n=40; Touch Surgery simulator + traditional training) and the control group (n=40; traditional training only). Data were collected at baseline, immediately after the intervention, and 4 weeks later. The study utilized several measures of knowledge test based on a previously validated instrument, Skill Lab observational checklist, Perceived Perioperative Competence Scale-Revised (PPCS-R), and Safety Attitudes Questionnaire (SAQ). Repeated Measures ANOVA analysis was applied.Results

Equally balanced distribution was revealed for all variables at baseline. Significant time × group interaction effects were found to be associated with superior improvement in the level of knowledge (P<0.001, Partial η²=0.147) and simulated clinical performance (P<0.001, Partial η²=0.195; Cohen's d=1.08) achieved by participants in the experimental group compared to those in the control group. Besides, the increase in perceived competence was considerably faster (P<0.001, Partial η²=0.269) in the experimental group than in the control group. Changes in the scores for the SAQ showed no statistically significant differential changes between groups (P=0.373).Conclusion

It can be concluded that the application of the Touch Surgery simulator represents an effective complement to surgical training, contributing to a rapid improvement in cognitive skills and simulated scrub-role performance, as well as increasing perceived competence in operating room technology students. Nonetheless, it is possible that inducing considerable change in safety attitudes requires the integration of cognitive simulators into team-based clinical environments.Trial registration

UMIN Clinical Trials Registry (UMIN-CTR), UMIN000062522. Registered on 8 August 2026. Retrospectively registered.

Related

  1. SEM-based parallel and serial mediation linking instructor technology integration competence to academic performance in AI-supported online learning
    Münevver Başman, Gökçen Seyra Çakır
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  2. Perioperative intravenous lidocaine for the prevention of chronic postsurgical pain: a systematic review and meta-analysis of randomized controlled trials
    Wei-Jing Zhu, Ran An, Qian-Yun Pang +1
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Evidence-Based Nursing Combined With Structured Psychological Intervention for Perioperative Anxiety in Tubal Ectopic Pregnancy: A Randomized Controlled Trial
    Qianwei Sang, Qian Zhao, Linji Wu
    Psychiatry and clinical psychopharmacologyPeer-reviewedCC BY-NCFull textEpidemiology & public healthEurope PMCPMC
  4. Perioperative hydrocortisone for modulating stress and inflammation after microvascular decompression for hemifacial spasm: a single-center, randomized, assessor-blinded, controlled trial protocol
    Renchao Yu, Yinfu Xu, Jing Wang +3
    Frontiers in NeurologyPeer-reviewedCC BY 4.0Full textNeurologyCrossrefPMC
  5. Lung ultrasound-guided protocolized fluid management versus conventional central venous pressure-based management in monitoring extravascular lung water during the perioperative period of percutaneous nephrolithotomy: a randomized controlled trial.
    Xuan Yu, Zhiwei Wang, Xinpeng Xu +4
    Annals of medicinePeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{pourdel2026effect,
  title = {{Effect of a mobile-based cognitive simulator (Touch Surgery) on knowledge, simulated scrub-role performance, and perceived perioperative competence among operating room technology students: a randomized controlled trial.}},
  author = {Bahador Pourdel and Erfan Rajabi and Ehsan Memarbashi and Seyed Abolfazl Hosseini},
  journal = {BMC nursing},
  year = {2026},
  month = aug,
  doi = {10.1186/s12912-026-05317-0},
  url = {https://europepmc.org/article/MED/43079555},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Effect of a mobile-based cognitive simulator (Touch Surgery) on knowledge, simulated scrub-role performance, and perceived perioperative competence among operating room technology students: a randomized controlled trial.
AU  - Bahador Pourdel
AU  - Erfan Rajabi
AU  - Ehsan Memarbashi
AU  - Seyed Abolfazl Hosseini
PY  - 2026
DA  - 2026/08/31
JO  - BMC nursing
DO  - 10.1186/s12912-026-05317-0
UR  - https://europepmc.org/article/MED/43079555
AB  - Background  Surgical training is confronted with structural limitations, which have prompted worldwide movement towards mobile cognitive simulators. The aim of the current study was to investigate the effect of the use of the Touch Surgery simulator on knowledge of surgical procedures, clinical practice skills, perceived competence, and safety attitudes in operating room technology students performing laparoscopic cholecystectomy.Methods  A two-group parallel randomized controlled trial with repeated measurements was adopted in the study with 80 OR technology undergraduates allocated to the experimental group (n=40; Touch Surgery simulator + traditional training) and the control group (n=40; traditional training only). Data were collected at baseline, immediately after the intervention, and 4 weeks later. The study utilized several measures of knowledge test based on a previously validated instrument, Skill Lab observational checklist, Perceived Perioperative Competence Scale-Revised (PPCS-R), and Safety Attitudes Questionnaire (SAQ). Repeated Measures ANOVA analysis was applied.Results  Equally balanced distribution was revealed for all variables at baseline. Significant time × group interaction effects were found to be associated with superior improvement in the level of knowledge (P<0.001, Partial η²=0.147) and simulated clinical performance (P<0.001, Partial η²=0.195; Cohen's d=1.08) achieved by participants in the experimental group compared to those in the control group. Besides, the increase in perceived competence was considerably faster (P<0.001, Partial η²=0.269) in the experimental group than in the control group. Changes in the scores for the SAQ showed no statistically significant differential changes between groups (P=0.373).Conclusion  It can be concluded that the application of the Touch Surgery simulator represents an effective complement to surgical training, contributing to a rapid improvement in cognitive skills and simulated scrub-role performance, as well as increasing perceived competence in operating room technology students. Nonetheless, it is possible that inducing considerable change in safety attitudes requires the integration of cognitive simulators into team-based clinical environments.Trial registration  UMIN Clinical Trials Registry (UMIN-CTR), UMIN000062522. Registered on 8 August 2026. Retrospectively registered.
SN  - 1472-6955
ER  -