Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BY 4.0Polymers

Thermal Viscoelasticity and Edge Integrity of Hydrophobic Acrylic Polymers Under Injector Compression

  1. 1Department of Medicine and Health Sciences “V. Tiberio”, University of Molise, Via de Sanctis, 86100 Campobasso, Italy
  2. 2IRCCS Fondazione G.B. Bietti, Via Santo Stefano Rotondo, 6, 00184 Rome, Italy

Abstract

The mechanical response of foldable intraocular lenses during injector-based delivery is governed by the relaxation dynamics of their polymer networks. To quantify this behavior, we performed a comprehensive mechanical characterization over the physiological temperature range and used the resulting relaxation parameters to construct a time–temperature equivalence model. By transforming the Williams–Landel–Ferry relation to use the viscoelastic transition temperature as reference and inverting it to match the strain rate imposed by the injector, we defined an equivalent temperature that represents the thermomechanical state experienced by the material during rapid folding. This parameter converts the deformation rate into an intuitive thermal quantity, revealing whether the polymer behaves in a rubbery, viscoelastic, or frozen regime. The equivalent temperature was evaluated across a wide range of optical powers and compared with the viscoelastic transition temperature to determine the thermomechanical safety margin of each material. The distance between these two temperatures identifies whether the polymer operates in a dissipative regime, where relaxation processes are fast enough to accommodate deformation, or in a transition-limited regime, where elastic energy accumulation and microfracture become more likely. The three investigated lens families exhibit distinct thermomechanical stratification: one group consistently remains well below its transition temperature, another shows a narrow but stable margin, and the third approaches its transition temperature during folding, indicating reduced relaxation capability and increased susceptibility to edge damage. Overall, the equivalent temperature framework provides a physically grounded and clinically useful tool for modeling the prediction of risk probability linked to mechanical damage during lens implantation. It also offers a practical guideline: pre-warming the lens to its equivalent temperature places the material in the same rheological condition that it would have under slow deformation, thereby reducing the likelihood of chipping before insertion.

Related

  1. Strain Waves Generate Compression and Trigger Buckling in Active Polymers
    Wen-de Tian, Kang Chen, Tianhui Zhang
    arXivPreprintCC BY 4.0Full textPhysical chemistryBiological & medical physicsarXiv
  2. Biocatalytic Synthesis of Diethyl Succinate in Hydrophobic Trioctylphosphine Oxide (TOPO)-Based Reactive DES
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral chemistryEurope PMC
  3. Bead-Spring Model Analysis of Linear Viscoelasticity for Unentangled Multi-Cyclic Polystyrene Melts
    Yuya Doi, Takeshi Sato, Zhi-Chao Yan
    ChemRxivPreprintCC BY-NC-NDFull textGeneral chemistryChemRxiv
  4. Guest-guest interactions and their impact on molecular mobility: a simulation study of 5-fluorouracil adsorption and diffusion in hydrophobic zeolites
    Michael Fischer
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  5. Achieving Accurate Prediction of Water Adsorption in Mildly Hydrophobic MOFs
    Sabrina Grigoletto, Ruben Goeminne, Mohammad Wahiduzzaman +3
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
BibTeX
@article{nigris2026thermal,
  title = {{Thermal Viscoelasticity and Edge Integrity of Hydrophobic Acrylic Polymers Under Injector Compression}},
  author = {Antonio de Nigris and Domenico Gentile and Tommaso Rossi and Luigi Ambrosone},
  journal = {Polymers},
  year = {2026},
  month = oct,
  doi = {10.3390/polym18202482},
  url = {https://www.mdpi.com/2073-4360/18/20/2482},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Thermal Viscoelasticity and Edge Integrity of Hydrophobic Acrylic Polymers Under Injector Compression
AU  - Antonio de Nigris
AU  - Domenico Gentile
AU  - Tommaso Rossi
AU  - Luigi Ambrosone
PY  - 2026
DA  - 2026/10/01
JO  - Polymers
DO  - 10.3390/polym18202482
UR  - https://www.mdpi.com/2073-4360/18/20/2482
AB  - The mechanical response of foldable intraocular lenses during injector-based delivery is governed by the relaxation dynamics of their polymer networks. To quantify this behavior, we performed a comprehensive mechanical characterization over the physiological temperature range and used the resulting relaxation parameters to construct a time–temperature equivalence model. By transforming the Williams–Landel–Ferry relation to use the viscoelastic transition temperature as reference and inverting it to match the strain rate imposed by the injector, we defined an equivalent temperature that represents the thermomechanical state experienced by the material during rapid folding. This parameter converts the deformation rate into an intuitive thermal quantity, revealing whether the polymer behaves in a rubbery, viscoelastic, or frozen regime. The equivalent temperature was evaluated across a wide range of optical powers and compared with the viscoelastic transition temperature to determine the thermomechanical safety margin of each material. The distance between these two temperatures identifies whether the polymer operates in a dissipative regime, where relaxation processes are fast enough to accommodate deformation, or in a transition-limited regime, where elastic energy accumulation and microfracture become more likely. The three investigated lens families exhibit distinct thermomechanical stratification: one group consistently remains well below its transition temperature, another shows a narrow but stable margin, and the third approaches its transition temperature during folding, indicating reduced relaxation capability and increased susceptibility to edge damage. Overall, the equivalent temperature framework provides a physically grounded and clinically useful tool for modeling the prediction of risk probability linked to mechanical damage during lens implantation. It also offers a practical guideline: pre-warming the lens to its equivalent temperature places the material in the same rheological condition that it would have under slow deformation, thereby reducing the likelihood of chipping before insertion.
SN  - 2073-4360
ER  -