Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BY-NCJournal of orthopaedic case reports

Diagnostic Accuracy of an 18.5 mm² Magnetic Resonance Imaging Cross-Sectional Area Threshold for Predicting Graft Adequacy (≥8.0 mm) in Quadrupled Hamstring Anterior Cruciate Ligament Reconstruction.

  1. 1Department of Orthopaedics and Traumatology, Pushpagiri Institute of Medical Sciences and Research Centre, Tiruvalla, Kerala, India.

Abstract

A quadrupled semitendinosus (ST) graft diameter below 8.0 mm is associated with higher failure and revision rates after anterior cruciate ligament (ACL) reconstruction. Pre-operative identification of patients at risk of an undersized graft may facilitate planning for gracilis augmentation or alternative graft selection. To determine the diagnostic accuracy of a pre-operative Magnetic resonance imaging (MRI)-measured ST cross-sectional area (CSA) threshold of 18.5 mm² for predicting an intraoperative quadrupled graft diameter of at least 8.0 mm. Thirty-seven consecutive patients undergoing arthroscopic ACL reconstruction with a quadrupled ST autograft were enrolled in a prospective observational study. Pre-operative ST CSA was measured on axial MRI at the joint line by a single musculoskeletal radiologist blinded to intraoperative findings. Quadrupled ST graft diameter was measured intraoperatively with a standard graft-sizing block before any gracilis augmentation. A CSA cut-off of 18.5 mm², derived by receiver operating characteristic (ROC) analysis within this cohort, was evaluated against the 8.0 mm adequacy threshold using standard 2×2 diagnostic accuracy statistics. Pre-operative CSA was strongly correlated with graft diameter (Spearman's ρ = 0.948, P < 0.001). At the 18.5 mm² cut-off (adequate graft as the target condition), sensitivity was 100% (95% confidence interval [CI] 85.75-100%), specificity 84.62% (95% CI 54.55-98.08%), positive predictive value 92.31% (95% CI 77.03-97.72%), negative predictive value 100% (95% CI 71.51-100%), and overall accuracy 94.59% (95% CI 81.81-99.34%), with an area under the ROC curve of 0.986 (95% CI 0.957-1.000). All 11 patients with a pre-operative CSA below 18.5 mm² had an inadequate graft (<8.0 mm); two of the 13 patients with an inadequate graft had CSA ≥18.5 mm² (sensitivity 84.62% for detecting an inadequate graft). Pre-operative ST CSA below 18.5 mm² was associated with an intraoperative graft diameter <8.0 mm in all 11 patients below the threshold, although 2 of 13 undersized grafts were missed. This threshold may serve as a useful pre-operative screening metric to anticipate the need for graft augmentation, pending external validation.

Related

  1. Biomechanical Study of the Quadrupled Gracilis Tendon Graft for the Anterior Cruciate Ligament Reconstruction
    Ivan Levaj, Ivan Bojanić, Ana Pilipović +6
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  2. Functional Outcome in Arthroscopic Anterior Cruciate Ligament Reconstruction Using an Autologous Quadrupled Hamstring Tendon Versus Peroneus Longus Tendon Graft: A Comparative Study
    Abhishek Singh, Gagandeep Gupta, Samay Das +3
    Journal of Orthopaedic Case ReportsPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaDOAJEurope PMC
  3. Magnetic resonance imaging-based radiomics for predicting P53-mutated hepatocellular carcinoma: intratumoral and peritumoral analysis
    Jingfei Weng, Dinghua Yao, Qihu Zeng +3
    Translational cancer researchPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Multicentre medicoeconomic evaluation of cardiac magnetic resonance imaging for predicting coronary artery disease in left ventricular dysfunction: The CAMAREC study design
    Louis-Marie Desroche, Damien Mandry, Gregory Ducrocq +14
    Archives of cardiovascular diseasesPeer-reviewedLicence not stated3 citedGeneral biologyCardiovascular medicineHAL
  5. Diagnostic Accuracy of Preoperative Magnetic Resonance Imaging for Staging Endometrial Carcinoma: A Retrospective Single-Centre Study
    Arun Sanap, Sachin R Chaudhari, Ashwini Umredkar +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{mathew2026diagnostic,
  title = {{Diagnostic Accuracy of an 18.5 mm² Magnetic Resonance Imaging Cross-Sectional Area Threshold for Predicting Graft Adequacy (≥8.0 mm) in Quadrupled Hamstring Anterior Cruciate Ligament Reconstruction.}},
  author = {Thomas Mathew and Ashish Mathew and Salman Faris and Francis Johnson and Athul Krishna},
  journal = {Journal of orthopaedic case reports},
  year = {2026},
  month = nov,
  doi = {10.13107/jocr.2026.v16.i11.8510},
  url = {https://europepmc.org/article/MED/42997039},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Diagnostic Accuracy of an 18.5 mm² Magnetic Resonance Imaging Cross-Sectional Area Threshold for Predicting Graft Adequacy (≥8.0 mm) in Quadrupled Hamstring Anterior Cruciate Ligament Reconstruction.
AU  - Thomas Mathew
AU  - Ashish Mathew
AU  - Salman Faris
AU  - Francis Johnson
AU  - Athul Krishna
PY  - 2026
DA  - 2026/11/01
JO  - Journal of orthopaedic case reports
DO  - 10.13107/jocr.2026.v16.i11.8510
UR  - https://europepmc.org/article/MED/42997039
AB  - A quadrupled semitendinosus (ST) graft diameter below 8.0 mm is associated with higher failure and revision rates after anterior cruciate ligament (ACL) reconstruction. Pre-operative identification of patients at risk of an undersized graft may facilitate planning for gracilis augmentation or alternative graft selection. To determine the diagnostic accuracy of a pre-operative Magnetic resonance imaging (MRI)-measured ST cross-sectional area (CSA) threshold of 18.5 mm² for predicting an intraoperative quadrupled graft diameter of at least 8.0 mm. Thirty-seven consecutive patients undergoing arthroscopic ACL reconstruction with a quadrupled ST autograft were enrolled in a prospective observational study. Pre-operative ST CSA was measured on axial MRI at the joint line by a single musculoskeletal radiologist blinded to intraoperative findings. Quadrupled ST graft diameter was measured intraoperatively with a standard graft-sizing block before any gracilis augmentation. A CSA cut-off of 18.5 mm², derived by receiver operating characteristic (ROC) analysis within this cohort, was evaluated against the 8.0 mm adequacy threshold using standard 2×2 diagnostic accuracy statistics. Pre-operative CSA was strongly correlated with graft diameter (Spearman's ρ = 0.948, P < 0.001). At the 18.5 mm² cut-off (adequate graft as the target condition), sensitivity was 100% (95% confidence interval [CI] 85.75-100%), specificity 84.62% (95% CI 54.55-98.08%), positive predictive value 92.31% (95% CI 77.03-97.72%), negative predictive value 100% (95% CI 71.51-100%), and overall accuracy 94.59% (95% CI 81.81-99.34%), with an area under the ROC curve of 0.986 (95% CI 0.957-1.000). All 11 patients with a pre-operative CSA below 18.5 mm² had an inadequate graft (<8.0 mm); two of the 13 patients with an inadequate graft had CSA ≥18.5 mm² (sensitivity 84.62% for detecting an inadequate graft). Pre-operative ST CSA below 18.5 mm² was associated with an intraoperative graft diameter <8.0 mm in all 11 patients below the threshold, although 2 of 13 undersized grafts were missed. This threshold may serve as a useful pre-operative screening metric to anticipate the need for graft augmentation, pending external validation.
SN  - 2250-0685
SN  - 2321-3817
ER  -