Skip to content
DraconiticResearch
Search Sources API
190,332 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BY-NCStroke (Hoboken, N.J.)

Evaluation of Neuroangiography Settings and Protective Shielding on Radiation Exposure to Patient and Interventionist: A Comparative Dosimetric Study

4 affiliations
  1. 1Iranian Center of Neurological Research, Neuroscience Institute, Imam Khomeini Hospital Complex (Z.A., P.M.), Tehran University of Medical Sciences, Iran.
  2. 2Research Center for Social Determinants of Health, Research Institute for Metabolic and Obesity Disorders, Research Institute for Endocrine Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran (N.I.).
  3. 3Jamaica Hospital Medical Center, Queens, NY (B.N., M.N., P.M.).
  4. 4Department of Neurology, School of Medicine (P.M.), Tehran University of Medical Sciences, Iran.

Abstract

Background

Neuroendovascular procedures expose surgeons and patients to significant radiation, increasing long-term health risks. Despite the known effects of imaging parameters on radiation exposure, the relative impacts of different imaging and shielding strategies have been less studied. We aimed to assess the effects of digital subtraction angiography parameter modifications on operator and patient radiation doses.Methods

Using a phantom skull in a neuroendovascular suite, radiation was measured under varying digital subtraction angiography settings, including image intensifier distance, collimation, magnification, frame rate, and protective shielding. Operator exposure was recorded using a dosimeter, and patient dose was obtained from the angiography system. Each configuration was tested in 3 independent trials. One-way ANOVA was used to determine statistical significance.Results

Lowering the frame rate (5.2-fold) and moving the image intensifier closer to the patient (3.5-fold) significantly reduced operator exposure (P<0.0001). Double shielding reduced operator dose 10-fold (P<0.0001). Patient dose was minimized by reducing magnification (9.3-fold; P<0.0001), lowering the frame rate (2.4-fold; P<0.0001), and decreasing image intensifier distance (1.7-fold; P<0.0001). Collimation decreased operator dose but slightly increased patient skin dose. Optimal parameter combinations maintained operator exposure well below recommended safety limits while minimizing patient dose.Conclusions

Low frame rates, close image intensifier positioning, minimal magnification, and double shielding substantially reduce radiation risk for both operators and patients. These evidence-based configurations provide a practical framework for safer neuroendovascular procedures.

Related

  1. Dosimetric superiority of proton radiosurgery in liver cancer: an in silico comparative dosimetric study
    Jiaran Li, Tao Ma, Hao Zhou +7
    BMC CancerPeer-reviewedCC BYFull textOncologyDOAJ
  2. Pharmacokinetic and dosimetric evaluation of [177Lu]Lu-FAPI for stromal-targeted radionuclide therapy in triple-negative breast cancer: a preclinical biodistribution and dosimetry study
    Zhihua Tang, Lushan Yu, Ke Zhang
    Frontiers in OncologyPeer-reviewedCC BY 4.0OncologyFrontiersCrossref
  3. Comparative transcriptomic analysis reveals the protective mechanism of ferulic acid against lipopolysaccharide-induced ferroptosis in IPEC-J2 cells
    Jiayu Chen, Hongchao Li, Yaxuan Niu +7
    Frontiers in Veterinary SciencePeer-reviewedCC BY 4.0Full textGeneral medicinePMCEurope PMC
  4. Comparative assessment of the cytotoxicity of Nrf2-dependent signaling pathway modulators: the role of hormetic protective effect in Parkinson’s disease modeling in vitro
    A. V. Chechushkov, A. E. Serykh, M. V. Khrapova +4
    Сибирский научный медицинский журналPeer-reviewedCC BYFull textGeneral medicineDOAJ
  5. A comparative study of FLC and MPC strategies for battery-protective energy management in grid-connected DC microgrids with hybrid renewable sources
    Hanane Tasmant, Er-rebyiy Hamza, Chakib Alaoui +5
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{azizan2026evaluation,
  title = {{Evaluation of Neuroangiography Settings and Protective Shielding on Radiation Exposure to Patient and Interventionist: A Comparative Dosimetric Study}},
  author = {Zahra Azizan and Neda Izadi and Binesh Ninan and Mohsen Nouri and Pouria Moshayedi},
  journal = {Stroke (Hoboken, N.J.)},
  year = {2026},
  month = sep,
  doi = {10.1161/svin.125.002287},
  url = {https://europepmc.org/article/PMC/PMC13727182},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Evaluation of Neuroangiography Settings and Protective Shielding on Radiation Exposure to Patient and Interventionist: A Comparative Dosimetric Study
AU  - Zahra Azizan
AU  - Neda Izadi
AU  - Binesh Ninan
AU  - Mohsen Nouri
AU  - Pouria Moshayedi
PY  - 2026
DA  - 2026/09/18
JO  - Stroke (Hoboken, N.J.)
DO  - 10.1161/svin.125.002287
UR  - https://europepmc.org/article/PMC/PMC13727182
AB  - Background  Neuroendovascular procedures expose surgeons and patients to significant radiation, increasing long-term health risks. Despite the known effects of imaging parameters on radiation exposure, the relative impacts of different imaging and shielding strategies have been less studied. We aimed to assess the effects of digital subtraction angiography parameter modifications on operator and patient radiation doses.Methods  Using a phantom skull in a neuroendovascular suite, radiation was measured under varying digital subtraction angiography settings, including image intensifier distance, collimation, magnification, frame rate, and protective shielding. Operator exposure was recorded using a dosimeter, and patient dose was obtained from the angiography system. Each configuration was tested in 3 independent trials. One-way ANOVA was used to determine statistical significance.Results  Lowering the frame rate (5.2-fold) and moving the image intensifier closer to the patient (3.5-fold) significantly reduced operator exposure (P<0.0001). Double shielding reduced operator dose 10-fold (P<0.0001). Patient dose was minimized by reducing magnification (9.3-fold; P<0.0001), lowering the frame rate (2.4-fold; P<0.0001), and decreasing image intensifier distance (1.7-fold; P<0.0001). Collimation decreased operator dose but slightly increased patient skin dose. Optimal parameter combinations maintained operator exposure well below recommended safety limits while minimizing patient dose.Conclusions  Low frame rates, close image intensifier positioning, minimal magnification, and double shielding substantially reduce radiation risk for both operators and patients. These evidence-based configurations provide a practical framework for safer neuroendovascular procedures.
SN  - 2694-5746
ER  -