Three-Dimensional Computed Tomography–Based Mapping of the Intraosseous Safe Zone for Acetabular Cup Screw Fixation
- 1Department of Orthopedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
- 2Japan Data Science Consortium Co., Ltd, Bunkyo-ku, Tokyo, Japan
Abstract
Background:: Conventional safe zones are defined by the proximity of acetabular cup screws to intrapelvic vessels; however, this relationship varies among individuals. This study aimed to define the intraosseous safe zone in which the screws remain entirely within bone without penetrating the medial wall.
Methods:: Three-dimensional computed tomography data for 30 hips of female patients with normal acetabular morphology were analyzed. A hemispherical cup was positioned virtually, and screw trajectories were evaluated in 24 directions using a clock-face coordinate system referenced to the ipsilateral anterior superior iliac spine. Bone thickness was measured in each direction, and intraosseous safe zones were defined for screw lengths of 15, 20, 25, 30, 40, and 50 mm. Heatmaps were generated to visualize the distribution of safe regions, and the angular range in which screws remained intraosseous in all cases was determined.
Results:: The median patient age was 50.1 years. The intraosseous safe zone was consistently located in the posterosuperior region for all screw lengths. The extent of the safe zone significantly decreased as the screw length increased (p < 0.01), whereas shorter screws expanded the safe zone toward the posteroinferior region. The angular range of the intraosseous safe zone was consistently the greatest at the 11 and 11:30 o’clock positions for 15, 20, and 25 mm screws.
Conclusions:: The findings provide a useful framework for preoperative planning and conceptualizing safe screw trajectories in total hip arthroplasty.
Clinical Relevance:: Directing screws toward the posterosuperior acetabulum, particularly around the 11 o’clock region, may enhance safety by maintaining intraosseous fixation and avoiding intrapelvic neurovascular injury. Shorter screws may expand safe fixation options toward the posteroinferior region.
Related
- Open‐Source and Commercial 3‐Dimensional Computed Tomography Methods Show Limited Agreement for Classifying Acetabular Morphology in Patients Undergoing Hip Arthroscopy
- A Case Report on Multiple Impacted Teeth: A Three-Dimensional Radiological Evaluation by Cone-Beam Computed Tomography
- Electromagnetic navigation bronchoscopy-guided three-dimensional conformal microwave ablation for unresectable peripheral high-risk pulmonary nodules: a mid-term assessment with no real-time intraoperative CT/cone-beam computed tomography guidance
- A Three-Dimensional Radiological Evaluation of a Nasopalatine Cyst by Cone-Beam Computed Tomography: A Case Report
- Development of a Pelvic Finite Element Model for Future Assessment of Fixation Strategies in Both-Column Acetabular Fractures
BibTeX
@article{sato2026threedimensional,
title = {{Three-Dimensional Computed Tomography–Based Mapping of the Intraosseous Safe Zone for Acetabular Cup Screw Fixation}},
author = {Takamitsu Sato and Rui Hirasawa and Shigeo Hagiwara and Hiroyuki Kaneko and Hiroyuki Hamano and Yuya Kawarai and Junichi Nakamura and Seiji Ohtori},
journal = {JBJS Open Access},
year = {2026},
month = oct,
doi = {10.2106/jbjs.oa.26.00322},
url = {https://doi.org/10.2106/jbjs.oa.26.00322},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Three-Dimensional Computed Tomography–Based Mapping of the Intraosseous Safe Zone for Acetabular Cup Screw Fixation
AU - Takamitsu Sato
AU - Rui Hirasawa
AU - Shigeo Hagiwara
AU - Hiroyuki Kaneko
AU - Hiroyuki Hamano
AU - Yuya Kawarai
AU - Junichi Nakamura
AU - Seiji Ohtori
PY - 2026
DA - 2026/10/27
JO - JBJS Open Access
DO - 10.2106/jbjs.oa.26.00322
UR - https://doi.org/10.2106/jbjs.oa.26.00322
AB - Background:: Conventional safe zones are defined by the proximity of acetabular cup screws to intrapelvic vessels; however, this relationship varies among individuals. This study aimed to define the intraosseous safe zone in which the screws remain entirely within bone without penetrating the medial wall. Methods:: Three-dimensional computed tomography data for 30 hips of female patients with normal acetabular morphology were analyzed. A hemispherical cup was positioned virtually, and screw trajectories were evaluated in 24 directions using a clock-face coordinate system referenced to the ipsilateral anterior superior iliac spine. Bone thickness was measured in each direction, and intraosseous safe zones were defined for screw lengths of 15, 20, 25, 30, 40, and 50 mm. Heatmaps were generated to visualize the distribution of safe regions, and the angular range in which screws remained intraosseous in all cases was determined. Results:: The median patient age was 50.1 years. The intraosseous safe zone was consistently located in the posterosuperior region for all screw lengths. The extent of the safe zone significantly decreased as the screw length increased (p < 0.01), whereas shorter screws expanded the safe zone toward the posteroinferior region. The angular range of the intraosseous safe zone was consistently the greatest at the 11 and 11:30 o’clock positions for 15, 20, and 25 mm screws. Conclusions:: The findings provide a useful framework for preoperative planning and conceptualizing safe screw trajectories in total hip arthroplasty. Clinical Relevance:: Directing screws toward the posterosuperior acetabulum, particularly around the 11 o’clock region, may enhance safety by maintaining intraosseous fixation and avoiding intrapelvic neurovascular injury. Shorter screws may expand safe fixation options toward the posteroinferior region.
SN - 2472-7245
ER -