Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 29 min ago
PreprintCC BY-NC-ND 4.0arXiv

Multiple Instance Learning for Interpretable Plasmoid Detection in the FLARE Device

Abstract

Multiple instance learning (MIL) is a form of weakly supervised learning widely used in healthcare and biomedical imaging, where labels may be available for groups of observations ("bags") but not individual observations ("instances"). This setup is well-suited to plasmoid detection in magnetic reconnection experiments, since identifying dynamic magnetic structures is best accomplished taking in data from many time steps as a whole, as opposed to viewing frames in isolation. Instance-level consideration enables researchers to determine the range of times most affecting model output, thus serving as a tool for the temporal localization of plasmoids. Despite its success in the life sciences, to the best of our knowledge, MIL is yet to be reported in peer-reviewed plasma physics literature. We evaluate a MIL model against a convolutional recurrent neural network (CRNN), an architecture commonly found in plasma physics literature, on a plasmoid detection task, using a highly imbalanced dataset of 1152 magnetic reconnection shots from the FLARE device at PPPL. We demonstrate significant improvements in test performance (PR AUC: Δ=+0.0932, p=0.0039; F1: Δ=+0.0259, p=0.0488; Wilcoxon signed-rank test) against the CRNN model on full-channel input. We investigate the interpretability advantage provided by our MIL model for the temporal localization of plasmoids. Through its attention mechanism, we can discern relevant frames and even the number of plasmoids present in a shot. Overall, we show that MIL is a promising framework for similar event classification tasks in plasma physics.

Related

  1. Adaptive Relational Learning on Multi-instance Quantum Data with Photonic Processors
    Marcin Jastrzebski, Shang Yu, Raj B. Patel +1
    arXivPreprintarXiv licenceFull textCondensed matterOptics & photonicsarXiv
  2. Plasmoid Instability in Inhomogeneous Current Sheets
    Kazuma Ikeda, Ryusuke Numata
    arXivPreprintCC BY-NC-ND 4.0Full textPlasma physicsarXiv
  3. TetrisCNN for interpretable detection of phases of matter from experimental quantum simulator data
    Kacper Cybiński, Björn van Zwol, James Enouen +5
    arXivPreprintCC BY 4.0Full textCondensed matterQuantum physics & quantum informationarXiv
  4. Interpretable neural equation learning for high-dimensional materials data
    Philip Jacobson, Prasad Iyer, Remi Dingreville +1
    arXivPreprintCC BY-SA 4.0Full textCondensed matterarXiv
  5. Interpretable Meta-Learning for Multi-Objective Chemical Search
    Antonio Varagnolo, Yulia Pimonova, Michael G. Taylor +2
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
BibTeX
@misc{marsden2026multiple,
  title = {{Multiple Instance Learning for Interpretable Plasmoid Detection in the FLARE Device}},
  author = {Charles Marsden and Adam Robbins and Hantao Ji},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.22817},
  eprint = {2610.22817},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.22817},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - UNPB
TI  - Multiple Instance Learning for Interpretable Plasmoid Detection in the FLARE Device
AU  - Charles Marsden
AU  - Adam Robbins
AU  - Hantao Ji
PY  - 2026
DA  - 2026/10/16
PB  - arXiv
DO  - 10.48550/arxiv.2610.22817
UR  - https://arxiv.org/abs/2610.22817
AB  - Multiple instance learning (MIL) is a form of weakly supervised learning widely used in healthcare and biomedical imaging, where labels may be available for groups of observations ("bags") but not individual observations ("instances"). This setup is well-suited to plasmoid detection in magnetic reconnection experiments, since identifying dynamic magnetic structures is best accomplished taking in data from many time steps as a whole, as opposed to viewing frames in isolation. Instance-level consideration enables researchers to determine the range of times most affecting model output, thus serving as a tool for the temporal localization of plasmoids. Despite its success in the life sciences, to the best of our knowledge, MIL is yet to be reported in peer-reviewed plasma physics literature. We evaluate a MIL model against a convolutional recurrent neural network (CRNN), an architecture commonly found in plasma physics literature, on a plasmoid detection task, using a highly imbalanced dataset of 1152 magnetic reconnection shots from the FLARE device at PPPL. We demonstrate significant improvements in test performance (PR AUC: Δ=+0.0932, p=0.0039; F1: Δ=+0.0259, p=0.0488; Wilcoxon signed-rank test) against the CRNN model on full-channel input. We investigate the interpretability advantage provided by our MIL model for the temporal localization of plasmoids. Through its attention mechanism, we can discern relevant frames and even the number of plasmoids present in a shot. Overall, we show that MIL is a promising framework for similar event classification tasks in plasma physics.
ER  -