Association of peri-reperfusion oxygen exposure and early allograft dysfunction after deceased donor orthotopic liver transplantation: a retrospective cohort study
- 1Department of Anesthesiology, Duke University Medical Center, Durham, NC USA
- 2Department of Anesthesiology, Emory University School of Medicine, Emory University Hospital, 1364 Clifton Rd NE, Atlanta, GA 30322 USA
- 3Emory Critical Care Center, Atlanta, GA USA
Abstract
Background: Hepatic insufficiency within a week of orthotopic liver transplantation (OLT), termed early allograft dysfunction (EAD), occurs in 20–25% of deceased donor OLT recipients and carries substantial morbidity and mortality. Ischemia reperfusion injury, in which reperfusion after ischemia provokes oxidative stress and inflammation, underlies EAD. We hypothesized higher peri-reperfusion oxygen exposure is associated with EAD.
Methods: We conducted a retrospective single-center cohort study of 963 primary adult deceased-donor static cold storage OLT recipients, January 2014 to May 2022. The primary outcome was EAD (serum bilirubin, international normalized ratio, and aminotransferases). Peri-reperfusion oxygen exposure was assessed by median partial pressure of arterial oxygen (PaO2) from 30 min before to 2 h after reperfusion. PaO2 was examined continuously, and a data-derived dichotomized cutpoint was sought. Associations were evaluated by logistic regression adjusted for donor age, total ischemia time, recipient body mass index, alcohol-associated liver disease, and metabolic dysfunction-associated steatohepatitis, with missing data handled by multiple imputation. Sensitivity analyses addressed exposure timing, anesthesiologist inspired-oxygen preference, and early lactate clearance.
Results: EAD occurred in 199 of 963 recipients (21%). Modeled continuously, higher PaO2 was associated with EAD after adjustment (adjusted OR 1.16 per 50 mmHg [95% CI 1.01–1.34]). The complete-case estimate was nearly identical but less precise (1.14 [95% CI 0.97–1.34]), with no detected departure from linearity (p = 0.28, multiple imputation). The association could not be localized to the pre- or post-reperfusion window. The estimate changed little after adjusting for early lactate clearance, and the association remained evident within the low-inspired-oxygen stratum; the high-inspired-oxygen stratum was uninformative owing to limited exposure contrast. No cutpoint could be identified across the 205 candidate thresholds searched (complete cases; global p = 0.18).
Conclusions: Higher peri-reperfusion PaO2 was associated with EAD after adjustment; the association could not be statistically localized to the pre- or post-reperfusion window. Whether this reflects a modifiable causal factor, a marker of early graft dysfunction, or both remains uncertain. External validation and prospective trials are needed to determine whether conservative oxygen management reduces EAD risk.
Related
- Ischemia–Reperfusion Injury and Primary Graft Dysfunction in Lung Transplantation from Uncontrolled Donation After Circulatory Death: A Donor–Graft–Recipient Continuum
- Orthotopic heart transplantation associated with hemiarch reconstruction for advanced heart failure and chronic aortic dissection: a case report.
- Association Between Lactate Levels upon ICU Admission After Liver Transplantation and the Burden of In-Hospital Complications: A Retrospective Cohort Study
- Association between intraoperative alactic base excess and postoperative acute kidney injury after liver transplantation: a retrospective cohort study
- Pentraxin-3 dynamics during liver transplantation and association with early allograft dysfunction
BibTeX
@article{wilson2026association,
title = {{Association of peri-reperfusion oxygen exposure and early allograft dysfunction after deceased donor orthotopic liver transplantation: a retrospective cohort study}},
author = {Elizabeth A. Wilson and Gaurav P. Patel and David W. Boorman and Craig S. Jabaley},
journal = {BMC Anesthesiology},
year = {2026},
month = aug,
doi = {10.1186/s12871-026-04217-9},
url = {https://doi.org/10.1186/s12871-026-04217-9},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Association of peri-reperfusion oxygen exposure and early allograft dysfunction after deceased donor orthotopic liver transplantation: a retrospective cohort study
AU - Elizabeth A. Wilson
AU - Gaurav P. Patel
AU - David W. Boorman
AU - Craig S. Jabaley
PY - 2026
DA - 2026/08/29
JO - BMC Anesthesiology
DO - 10.1186/s12871-026-04217-9
UR - https://doi.org/10.1186/s12871-026-04217-9
AB - Background: Hepatic insufficiency within a week of orthotopic liver transplantation (OLT), termed early allograft dysfunction (EAD), occurs in 20–25% of deceased donor OLT recipients and carries substantial morbidity and mortality. Ischemia reperfusion injury, in which reperfusion after ischemia provokes oxidative stress and inflammation, underlies EAD. We hypothesized higher peri-reperfusion oxygen exposure is associated with EAD. Methods: We conducted a retrospective single-center cohort study of 963 primary adult deceased-donor static cold storage OLT recipients, January 2014 to May 2022. The primary outcome was EAD (serum bilirubin, international normalized ratio, and aminotransferases). Peri-reperfusion oxygen exposure was assessed by median partial pressure of arterial oxygen (PaO2) from 30 min before to 2 h after reperfusion. PaO2 was examined continuously, and a data-derived dichotomized cutpoint was sought. Associations were evaluated by logistic regression adjusted for donor age, total ischemia time, recipient body mass index, alcohol-associated liver disease, and metabolic dysfunction-associated steatohepatitis, with missing data handled by multiple imputation. Sensitivity analyses addressed exposure timing, anesthesiologist inspired-oxygen preference, and early lactate clearance. Results: EAD occurred in 199 of 963 recipients (21%). Modeled continuously, higher PaO2 was associated with EAD after adjustment (adjusted OR 1.16 per 50 mmHg [95% CI 1.01–1.34]). The complete-case estimate was nearly identical but less precise (1.14 [95% CI 0.97–1.34]), with no detected departure from linearity (p = 0.28, multiple imputation). The association could not be localized to the pre- or post-reperfusion window. The estimate changed little after adjusting for early lactate clearance, and the association remained evident within the low-inspired-oxygen stratum; the high-inspired-oxygen stratum was uninformative owing to limited exposure contrast. No cutpoint could be identified across the 205 candidate thresholds searched (complete cases; global p = 0.18). Conclusions: Higher peri-reperfusion PaO2 was associated with EAD after adjustment; the association could not be statistically localized to the pre- or post-reperfusion window. Whether this reflects a modifiable causal factor, a marker of early graft dysfunction, or both remains uncertain. External validation and prospective trials are needed to determine whether conservative oxygen management reduces EAD risk.
SN - 1471-2253
ER -