Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 54 min ago
Peer-reviewedCC BYFrontiers in oncology

Total body irradiation practice patterns: insights from a national survey

4 affiliations
  1. 1Department of Oncology, King Faisal Specialist Hospital and Research Centre , ,
  2. 2Radiation Oncology Section, Department of Oncology, King Abdullah Specialized Children's Hospital, Ministry of the National Guard-Health Affairs , ,
  3. 3Department of Health Administration and Medical Information, College of Health Science at Al-Leith, Umm Al-Qura University , ,
  4. 4Department of Radiation Oncology, King Fahad Specialist Hospital-Dammam , ,

Abstract

Purpose: Despite the expansion of hematopoietic stem cell transplantation (HSCT) services, contemporary Total Body Irradiation (TBI) practices remain insufficiently characterized in many healthcare settings. This study aimed to establish a national baseline for TBI practice to support benchmarking, standardization, and quality improvement.

Materials and methods: A cross-sectional online survey was distributed between May and June 2026 to seven Saudi centers that provided TBI services. The questionnaire collected data on service capacity, patient populations, dose fractionation, treatment techniques and delivery, planning methods, and quality assurance. A census sampling approach was used, inviting Radiation Oncologists, Medical Physicists, and Therapists. Data were analyzed using descriptive statistics in Python (v3.11).

Results: All seven centers responded. One center (C) submitted two responses covering conventional extended source-to-surface distance (SSD) and volumetric-modulated arc therapy (VMAT) practices. Commissioned between 1980 and 2020, the TBI programs manage an estimated 386 annual cases (range: 12–120). Fractionated TBI (10–12 Gy, six twice-daily fractions) predominated. The extended SSD opposed-beam technique remained in use at six centers, with the umbilicus as the most common prescription point. At two centers, extended-SSD TBI was used alongside Intensity-modulated radiation therapy (IMRT)-TBI (VMAT and Tomotherapy. IMRT-TBI-based centers reported volumetric target-coverage objectives of 90% and explicit organ-at-risk (OAR) dose planning constraints, particularly for the lungs and kidneys. Treatment planning for IMRT-TBI involved treatment planning systems (TPS), whereas extended-SSD techniques used varied planning approaches, including in-house spreadsheets, pre-calculated templates, and, in some cases, TPS-assisted planning. In vivo dosimetry was performed at all centers. The absorbed dose-rate at the prescription point ranged from <10 to 30 cGy/min for conventional techniques. Three centers planned their initial implementation of IMRT-TBI within three years. The ability to control OARs was the main driver, while linear accelerator availability and staff training were key barriers.

Conclusions: Although conventional extended SSD TBI remains the most widely used technique, TBI practice is transitioning toward IMRT-based delivery. National practice guidelines based on existing international recommendations may help standardize care, address implementation barriers, and support the delivery of high-quality TBI services across treatment centers.

Related

  1. Clinical approaches to re-irradiation in the MENA region: insights from 115 radiation oncologists.
    Rim Alami, Reyzane El Mjabber, Raouia Ben Amor +7
    Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation OncologyPeer-reviewedCC BY-NC-NDFull textApplied physics & instrumentationEurope PMC
  2. Stagewise evolution of nanovoids into nanotrenches on SiC under ultrafast laser irradiation
    Lin Chen, Chen Gao, Guodong Zhang +3
    Optics LettersPeer-reviewedCC BY-NC-ND 4.0Full textGeneral physicsHAL
  3. Sub-pixel nanosecond laser irradiation of a color CMOS image sensor: damage thresholds and the role of the color filter array
    Cong Doan, Toan Nguyen, Lien Nghiem +2
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Beyond Hippocampal Avoidance: Early Experience With Memory-Network Avoidance Prophylactic Cranial Irradiation in Small Cell Lung Cancer.
    Tugce Kutuk, Marshall Harrell, Alexander Crum +4
    Advances in radiation oncologyPeer-reviewedCC BY-NC-NDFull textApplied physics & instrumentationEurope PMC
  5. Enhanced radiation resistance and pre-irradiation effects of hydroxyl-containing fluorine-doped silica optical fibers at 1550 nm
    Youngwoong Kim, Jong-Yeol Kim, gukbeen ryu +4
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
BibTeX
@article{mulla2026total,
  title = {{Total body irradiation practice patterns: insights from a national survey}},
  author = {Zaheeda Mulla and Ali Balbaid and Ghada Aldosary and Wsam Ghandourh and Ismail AlDahlawi and Mohamed Bayoumy and Mohannad Alhumaid and Fahad Alrowais and Hussain Almerdhemah and Hiba Taha and Abdullah AlMohamad and Wasil Jastaniah},
  journal = {Frontiers in oncology},
  year = {2026},
  month = oct,
  doi = {10.3389/fonc.2026.1960445},
  url = {https://europepmc.org/article/PMC/PMC13690712},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Total body irradiation practice patterns: insights from a national survey
AU  - Zaheeda Mulla
AU  - Ali Balbaid
AU  - Ghada Aldosary
AU  - Wsam Ghandourh
AU  - Ismail AlDahlawi
AU  - Mohamed Bayoumy
AU  - Mohannad Alhumaid
AU  - Fahad Alrowais
AU  - Hussain Almerdhemah
AU  - Hiba Taha
AU  - Abdullah AlMohamad
AU  - Wasil Jastaniah
PY  - 2026
DA  - 2026/10/09
JO  - Frontiers in oncology
DO  - 10.3389/fonc.2026.1960445
UR  - https://europepmc.org/article/PMC/PMC13690712
AB  - Purpose: Despite the expansion of hematopoietic stem cell transplantation (HSCT) services, contemporary Total Body Irradiation (TBI) practices remain insufficiently characterized in many healthcare settings. This study aimed to establish a national baseline for TBI practice to support benchmarking, standardization, and quality improvement.  Materials and methods: A cross-sectional online survey was distributed between May and June 2026 to seven Saudi centers that provided TBI services. The questionnaire collected data on service capacity, patient populations, dose fractionation, treatment techniques and delivery, planning methods, and quality assurance. A census sampling approach was used, inviting Radiation Oncologists, Medical Physicists, and Therapists. Data were analyzed using descriptive statistics in Python (v3.11).  Results: All seven centers responded. One center (C) submitted two responses covering conventional extended source-to-surface distance (SSD) and volumetric-modulated arc therapy (VMAT) practices. Commissioned between 1980 and 2020, the TBI programs manage an estimated 386 annual cases (range: 12–120). Fractionated TBI (10–12 Gy, six twice-daily fractions) predominated. The extended SSD opposed-beam technique remained in use at six centers, with the umbilicus as the most common prescription point. At two centers, extended-SSD TBI was used alongside Intensity-modulated radiation therapy (IMRT)-TBI (VMAT and Tomotherapy. IMRT-TBI-based centers reported volumetric target-coverage objectives of 90% and explicit organ-at-risk (OAR) dose planning constraints, particularly for the lungs and kidneys. Treatment planning for IMRT-TBI involved treatment planning systems (TPS), whereas extended-SSD techniques used varied planning approaches, including in-house spreadsheets, pre-calculated templates, and, in some cases, TPS-assisted planning. In vivo dosimetry was performed at all centers. The absorbed dose-rate at the prescription point ranged from <10 to 30 cGy/min for conventional techniques. Three centers planned their initial implementation of IMRT-TBI within three years. The ability to control OARs was the main driver, while linear accelerator availability and staff training were key barriers.  Conclusions: Although conventional extended SSD TBI remains the most widely used technique, TBI practice is transitioning toward IMRT-based delivery. National practice guidelines based on existing international recommendations may help standardize care, address implementation barriers, and support the delivery of high-quality TBI services across treatment centers.
SN  - 2234-943X
ER  -