Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 34 min ago
Peer-reviewedCC BYAlzheimer's research & therapy

A prospective observational study measuring the stability of plasma pTau181 using the Elecsys Phospho-Tau (181P) plasma immunoassay for early detection of Alzheimer's disease.

7 affiliations
  1. 1Department of Psychiatry and Psychotherapy, LMU University Hospital, LMU Medizin, Ludwig-Maximilians-Universität München, Munich, 80336, Germany. [email protected].
  2. 2Department of Psychiatry and Psychotherapy, School of Medicine and Health, Technical University Munich, Munich, 81675, Germany. [email protected].
  3. 3Department of Psychiatry and Psychotherapy, LMU University Hospital, LMU Medizin, Ludwig-Maximilians-Universität München, Munich, 80336, Germany.
  4. 4Study Delivery CVMD Core Lab, Roche Diagnostics GmbH, Penzberg, 82377, Germany.
  5. 5Biostatistics & Data Science, Roche Diagnostics GmbH, Penzberg, 82377, Germany.
  6. 6Assay Development New Products - PD PHCS, Roche Diagnostics GmbH, Penzberg, 82377, Germany.
  7. 7German Center for Neurodegenerative Diseases (DZNE), Munich, 81377, Germany.

Abstract

Background

Plasma tau phosphorylated at threonine 181 (pTau181) is a key blood-based biomarker that correlates with the burden of amyloid-beta (Aβ) pathology in Alzheimer's disease (AD). The Elecsys® Phospho-Tau (181P) Plasma (pT181p) immunoassay (Roche Diagnostics International Ltd, Rotkreuz, Switzerland) is intended for use as an aid in the early detection of Aβ pathology in adults ≥ 55 years presenting with complaints of cognitive decline and is Conformité Européenne-marked and approved for clinical use by the US FDA. Here, we evaluated the stability of plasma pTau181 measured using the pT181p immunoassay under different pre-analytical and storage conditions in samples from an intended-use population.Methods

Whole blood samples from individuals presenting at LMU Hospital with symptom severity ranging from subjective cognitive decline to moderate AD dementia were collected in three different tubes for plasma preparation (Li-Heparin, K2-EDTA, and K3-EDTA). These were transported under cooled (never frozen) conditions to the measurement site and processed within 6 h of collection. Plasma samples were stored at different temperatures for varying durations, and impact on plasma pTau181 recoveries was assessed.Results

Out-of-specification results not meeting pre-defined acceptance criteria observed in an initial cohort (n = 14), were found to be the result of buffy coat/erythrocyte contamination. Pre-analytical procedures were modified to prevent contamination during post-centrifugation plasma transfer. In samples from a separate cohort (n = 10), no instabilities were observed and acceptance criteria were met. After considering safety margins, analyte stability for all sample types was determined to be 2 days at 25 °C, 7 days at 4 °C, 12 weeks at -20 °C, and 16 weeks at -80°C; stability was also observed after one freeze/thaw cycle.Conclusions

pT181p immunoassay measurements were stable and robust with respect to different sample handling procedures and storage conditions. These findings support implementation of the assay into routine, non-specialist healthcare settings to facilitate practical blood-based testing to rule out AD-related Aβ pathology.

Related

  1. A Prospective, Observational, Open-Label, Nonrandomized, Multicenter Study Measuring Functional Outcomes in a Novel Interspinous Stabilization Device in Patients With Low Back Pain: 12-Month Results for the REFINE Study
    Steven M. Falowski, Louis J. Raso, Vipul Mangal +10
    International Journal of Spine SurgeryPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  2. Magnitude and associated factors of delayed clinical stability among adult patients with severe community-acquired pneumonia admitted to the University of Gondar Comprehensive Specialized Hospital, Northwest Ethiopia in 2024/2025: a prospective observational study
    Getasew Muluken Abebe, Tadilo Biset Melese, Bethel Gezahegn Bogale +9
    BMJ OpenPeer-reviewedLicence not statedGeneral medicineCrossref
  3. Sampling composition and sequencing effort in the detection of within-hospital Gram-negative genomic clustering: a prospective observational study at two tertiary-care hospitals
    L. Knegendorf, J. Erdmann, K. L. Nielsen +5
    medRxivPreprintAll rights reservedFull textInfectious diseasemedRxiv
  4. Postural stability in young adults with low-degree refractive errors: A prospective observational study
    Emine Çetin Duru, Aynura Sariyeva Aydamirov, Ayna Sariyeva Ismayilov
    The Journal of International Medical ResearchPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
  5. Relationship between molecular pathogen detection and clinical disease in febrile children across Europe: a multicentre, prospective observational study
    Priyen Shah, Marie Voice, Leonides Calvo-Bado +351
    The Lancet Regional Health - EuropePeer-reviewedCC BY26 citedGeneral biologyInfectious diseaseHAL
BibTeX
@article{kurz2026prospective,
  title = {{A prospective observational study measuring the stability of plasma pTau181 using the Elecsys Phospho-Tau (181P) plasma immunoassay for early detection of Alzheimer's disease.}},
  author = {Carolin Kurz and Sophia Leonhardt and Anna Hufnagel and Sabine Wizemann and Heike Deutelmoser and Patrick Menzel and Robert Perneczky},
  journal = {Alzheimer's research \& therapy},
  year = {2026},
  month = oct,
  doi = {10.1186/s13195-026-02238-7},
  url = {https://europepmc.org/article/MED/42958309},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - A prospective observational study measuring the stability of plasma pTau181 using the Elecsys Phospho-Tau (181P) plasma immunoassay for early detection of Alzheimer's disease.
AU  - Carolin Kurz
AU  - Sophia Leonhardt
AU  - Anna Hufnagel
AU  - Sabine Wizemann
AU  - Heike Deutelmoser
AU  - Patrick Menzel
AU  - Robert Perneczky
PY  - 2026
DA  - 2026/10/24
JO  - Alzheimer's research & therapy
DO  - 10.1186/s13195-026-02238-7
UR  - https://europepmc.org/article/MED/42958309
AB  - Background  Plasma tau phosphorylated at threonine 181 (pTau181) is a key blood-based biomarker that correlates with the burden of amyloid-beta (Aβ) pathology in Alzheimer's disease (AD). The Elecsys® Phospho-Tau (181P) Plasma (pT181p) immunoassay (Roche Diagnostics International Ltd, Rotkreuz, Switzerland) is intended for use as an aid in the early detection of Aβ pathology in adults ≥ 55 years presenting with complaints of cognitive decline and is Conformité Européenne-marked and approved for clinical use by the US FDA. Here, we evaluated the stability of plasma pTau181 measured using the pT181p immunoassay under different pre-analytical and storage conditions in samples from an intended-use population.Methods  Whole blood samples from individuals presenting at LMU Hospital with symptom severity ranging from subjective cognitive decline to moderate AD dementia were collected in three different tubes for plasma preparation (Li-Heparin, K2-EDTA, and K3-EDTA). These were transported under cooled (never frozen) conditions to the measurement site and processed within 6 h of collection. Plasma samples were stored at different temperatures for varying durations, and impact on plasma pTau181 recoveries was assessed.Results  Out-of-specification results not meeting pre-defined acceptance criteria observed in an initial cohort (n = 14), were found to be the result of buffy coat/erythrocyte contamination. Pre-analytical procedures were modified to prevent contamination during post-centrifugation plasma transfer. In samples from a separate cohort (n = 10), no instabilities were observed and acceptance criteria were met. After considering safety margins, analyte stability for all sample types was determined to be 2 days at 25 °C, 7 days at 4 °C, 12 weeks at -20 °C, and 16 weeks at -80°C; stability was also observed after one freeze/thaw cycle.Conclusions  pT181p immunoassay measurements were stable and robust with respect to different sample handling procedures and storage conditions. These findings support implementation of the assay into routine, non-specialist healthcare settings to facilitate practical blood-based testing to rule out AD-related Aβ pathology.
SN  - 1758-9193
ER  -