A prospective observational study measuring the stability of plasma pTau181 using the Elecsys Phospho-Tau (181P) plasma immunoassay for early detection of Alzheimer's disease.
7 affiliations
- 1Department of Psychiatry and Psychotherapy, LMU University Hospital, LMU Medizin, Ludwig-Maximilians-Universität München, Munich, 80336, Germany. [email protected].
- 2Department of Psychiatry and Psychotherapy, School of Medicine and Health, Technical University Munich, Munich, 81675, Germany. [email protected].
- 3Department of Psychiatry and Psychotherapy, LMU University Hospital, LMU Medizin, Ludwig-Maximilians-Universität München, Munich, 80336, Germany.
- 4Study Delivery CVMD Core Lab, Roche Diagnostics GmbH, Penzberg, 82377, Germany.
- 5Biostatistics & Data Science, Roche Diagnostics GmbH, Penzberg, 82377, Germany.
- 6Assay Development New Products - PD PHCS, Roche Diagnostics GmbH, Penzberg, 82377, Germany.
- 7German Center for Neurodegenerative Diseases (DZNE), Munich, 81377, Germany.
Abstract
Background
Plasma tau phosphorylated at threonine 181 (pTau181) is a key blood-based biomarker that correlates with the burden of amyloid-beta (Aβ) pathology in Alzheimer's disease (AD). The Elecsys® Phospho-Tau (181P) Plasma (pT181p) immunoassay (Roche Diagnostics International Ltd, Rotkreuz, Switzerland) is intended for use as an aid in the early detection of Aβ pathology in adults ≥ 55 years presenting with complaints of cognitive decline and is Conformité Européenne-marked and approved for clinical use by the US FDA. Here, we evaluated the stability of plasma pTau181 measured using the pT181p immunoassay under different pre-analytical and storage conditions in samples from an intended-use population.Methods
Whole blood samples from individuals presenting at LMU Hospital with symptom severity ranging from subjective cognitive decline to moderate AD dementia were collected in three different tubes for plasma preparation (Li-Heparin, K2-EDTA, and K3-EDTA). These were transported under cooled (never frozen) conditions to the measurement site and processed within 6 h of collection. Plasma samples were stored at different temperatures for varying durations, and impact on plasma pTau181 recoveries was assessed.Results
Out-of-specification results not meeting pre-defined acceptance criteria observed in an initial cohort (n = 14), were found to be the result of buffy coat/erythrocyte contamination. Pre-analytical procedures were modified to prevent contamination during post-centrifugation plasma transfer. In samples from a separate cohort (n = 10), no instabilities were observed and acceptance criteria were met. After considering safety margins, analyte stability for all sample types was determined to be 2 days at 25 °C, 7 days at 4 °C, 12 weeks at -20 °C, and 16 weeks at -80°C; stability was also observed after one freeze/thaw cycle.Conclusions
pT181p immunoassay measurements were stable and robust with respect to different sample handling procedures and storage conditions. These findings support implementation of the assay into routine, non-specialist healthcare settings to facilitate practical blood-based testing to rule out AD-related Aβ pathology.
Related
- A Prospective, Observational, Open-Label, Nonrandomized, Multicenter Study Measuring Functional Outcomes in a Novel Interspinous Stabilization Device in Patients With Low Back Pain: 12-Month Results for the REFINE Study
- Magnitude and associated factors of delayed clinical stability among adult patients with severe community-acquired pneumonia admitted to the University of Gondar Comprehensive Specialized Hospital, Northwest Ethiopia in 2024/2025: a prospective observational study
- Sampling composition and sequencing effort in the detection of within-hospital Gram-negative genomic clustering: a prospective observational study at two tertiary-care hospitals
- Postural stability in young adults with low-degree refractive errors: A prospective observational study
- Relationship between molecular pathogen detection and clinical disease in febrile children across Europe: a multicentre, prospective observational study
BibTeX
@article{kurz2026prospective,
title = {{A prospective observational study measuring the stability of plasma pTau181 using the Elecsys Phospho-Tau (181P) plasma immunoassay for early detection of Alzheimer's disease.}},
author = {Carolin Kurz and Sophia Leonhardt and Anna Hufnagel and Sabine Wizemann and Heike Deutelmoser and Patrick Menzel and Robert Perneczky},
journal = {Alzheimer's research \& therapy},
year = {2026},
month = oct,
doi = {10.1186/s13195-026-02238-7},
url = {https://europepmc.org/article/MED/42958309},
note = {CC BY},
}
RIS
TY - JOUR
TI - A prospective observational study measuring the stability of plasma pTau181 using the Elecsys Phospho-Tau (181P) plasma immunoassay for early detection of Alzheimer's disease.
AU - Carolin Kurz
AU - Sophia Leonhardt
AU - Anna Hufnagel
AU - Sabine Wizemann
AU - Heike Deutelmoser
AU - Patrick Menzel
AU - Robert Perneczky
PY - 2026
DA - 2026/10/24
JO - Alzheimer's research & therapy
DO - 10.1186/s13195-026-02238-7
UR - https://europepmc.org/article/MED/42958309
AB - Background Plasma tau phosphorylated at threonine 181 (pTau181) is a key blood-based biomarker that correlates with the burden of amyloid-beta (Aβ) pathology in Alzheimer's disease (AD). The Elecsys® Phospho-Tau (181P) Plasma (pT181p) immunoassay (Roche Diagnostics International Ltd, Rotkreuz, Switzerland) is intended for use as an aid in the early detection of Aβ pathology in adults ≥ 55 years presenting with complaints of cognitive decline and is Conformité Européenne-marked and approved for clinical use by the US FDA. Here, we evaluated the stability of plasma pTau181 measured using the pT181p immunoassay under different pre-analytical and storage conditions in samples from an intended-use population.Methods Whole blood samples from individuals presenting at LMU Hospital with symptom severity ranging from subjective cognitive decline to moderate AD dementia were collected in three different tubes for plasma preparation (Li-Heparin, K2-EDTA, and K3-EDTA). These were transported under cooled (never frozen) conditions to the measurement site and processed within 6 h of collection. Plasma samples were stored at different temperatures for varying durations, and impact on plasma pTau181 recoveries was assessed.Results Out-of-specification results not meeting pre-defined acceptance criteria observed in an initial cohort (n = 14), were found to be the result of buffy coat/erythrocyte contamination. Pre-analytical procedures were modified to prevent contamination during post-centrifugation plasma transfer. In samples from a separate cohort (n = 10), no instabilities were observed and acceptance criteria were met. After considering safety margins, analyte stability for all sample types was determined to be 2 days at 25 °C, 7 days at 4 °C, 12 weeks at -20 °C, and 16 weeks at -80°C; stability was also observed after one freeze/thaw cycle.Conclusions pT181p immunoassay measurements were stable and robust with respect to different sample handling procedures and storage conditions. These findings support implementation of the assay into routine, non-specialist healthcare settings to facilitate practical blood-based testing to rule out AD-related Aβ pathology.
SN - 1758-9193
ER -