Diagnostic Utility of Accommodative Measurements by Nott Dynamic Retinoscopy in Children with Unilateral Amblyopia
14 affiliations
- 1Boston Children’s Hospital, Harvard Medical School, Boston, Massachusetts, USA
- 2Spencer Center for Vision Research, Byers Eye Institute at Stanford University, Palo Alto, California, USA
- 3Jaeb Center for Health Research, Tampa, Florida, USA
- 4The Ohio State University, Columbus, Ohio, USA
- 5University of Houston College of Optometry, Houston, Texas, USA
- 6Seattle Children’s Hospital, Seattle, Washington, USA
- 7Southern California College of Optometry at Marshall B Ketchum University, Fullerton, California, USA
- 8Wilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA
- 9Pennsylvania College of Optometry, Drexel University, Elkins Park, Pennsylvania, USA
- 10Vanderbilt Eye Institute, Nashville, Tennessee, USA
- 11Casey Eye Institute, Oregon Health & Science University, Portland, Oregon, USA
- 12Stein Eye Institute at the University of California, Los Angeles, Los Angeles, California, USA
- 13University of Alabama at Birmingham, Birmingham, Alabama, USA
- 14University of Arizona Tucson, Tucson, Arizona, USA
Abstract
PURPOSE: To evaluate the agreement and diagnostic utility of Nott Dynamic Retinoscopy (NDR) compared with instrument-based methods for assessing accommodative amplitude, accuracy and variability in children with unilateral amblyopia. METHODS: Children aged 5-10 years with unilateral amblyopia (6/12-6/30, N = 42) and without amblyopia (6/7.5 or better, N = 51) were enrolled. Accommodative parameters were assessed using NDR and instrument-based methods: Grand Seiko autorefractor for amplitude and accuracy and PowerRef 3 for variability. Participants monocularly viewed 6/45 letters on an iPod at 33 cm for accuracy and variability; the same letters were viewed at progressively closer test distances and through minus lenses for amplitude assessment. Agreement between NDR and instrument-based measures was evaluated using Bland-Altman analysis. Instrument-based values from controls established abnormal thresholds, defined as worse than the 1-sided 95% tolerance limits with 90% confidence. NDR cut-offs for detecting abnormal accommodation values were derived using receiver operating characteristic (ROC) curves. RESULTS: Agreement between NDR and instrument-based methods was poor for all accommodative parameters with wide limits of agreement. Based on instrument-based tolerance limits, 39% of amblyopic eyes had abnormal amplitude (≤6.63 D), 34% had abnormal accuracy (lag ≥2.12 D) and 7% had abnormal variability (≥0.98 D). For amplitude, an NDR cut-off ≤5.60 D provided 80% sensitivity (95% CI, 60-100%) and 80% specificity (95% CI, 64-96%) to detect abnormality (area under the ROC curve [AUROC] = 0.85). For accuracy, an NDR cut-off ≥1.55 D provided 92% sensitivity (95% CI, 76-100%) and 81% specificity (95% CI, 67-96%) (AUROC = 0.90). There were insufficient participants with abnormal accommodative variability using the PowerRef 3 to establish an NDR threshold. CONCLUSIONS: NDR is not interchangeable with instrument-based objective accommodative measures in children with and without amblyopia; however, it may be useful as a screening tool for abnormal accommodative amplitude and accuracy, pending confirmation in larger, independent cohorts.
Related
- OCT Assessment of Deep Optic Nerve Head, Subfoveal Choroidal Thickness, and Retinal Layers in Unilateral Anisometropic Amblyopia.
- Longitudinal Visual Recovery and Exploratory Neuroimaging Findings in Pediatric Deprivation Amblyopia Following Unilateral Congenital Cataract Extraction: A Prospective Cohort Study
- Repeatability of upper limb volume measurements based on the Kuhnke measurement protocol and frustum volume calculation in women after unilateral mastectomy: a cross-sectional methodological study
- Diagnostic performance of a combined TAP, TAM, CA125 and CA153 panel for stage I breast cancer in patients with unilateral nipple discharge
- Case of Partial Accommodative Esotropia With Well-Developed Binocular Function After Frequent Interventions
BibTeX
@article{raghuram2026diagnostic,
title = {{Diagnostic Utility of Accommodative Measurements by Nott Dynamic Retinoscopy in Children with Unilateral Amblyopia}},
author = {Aparna Raghuram and Tawna L. Roberts and Yufeng Zhu and Heather A. Anderson and Ruth E. Manny and Vivian M. Manh and Sophia M. Marusic and Surbhi Bansal and Kristina Tarczy-Hornoch and Michael X. Repka and Erin C. Jenewein and Siva Meiyeppen and Karen D. Fern and Emily K. Wiecek and David K. Wallace and Allison I. Summers and Robert J. Henderson and Wesley T. Beaulieu and Raymond T. Kraker and Stacy L. Pineles and Katherine K. Weise and Jonathan M. Holmes and Susan A. Cotter},
journal = {Ophthalmic \& physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)},
year = {2026},
month = nov,
doi = {10.1007/s44402-026-00228-8},
url = {https://doi.org/10.1007/s44402-026-00228-8},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Diagnostic Utility of Accommodative Measurements by Nott Dynamic Retinoscopy in Children with Unilateral Amblyopia
AU - Aparna Raghuram
AU - Tawna L. Roberts
AU - Yufeng Zhu
AU - Heather A. Anderson
AU - Ruth E. Manny
AU - Vivian M. Manh
AU - Sophia M. Marusic
AU - Surbhi Bansal
AU - Kristina Tarczy-Hornoch
AU - Michael X. Repka
AU - Erin C. Jenewein
AU - Siva Meiyeppen
AU - Karen D. Fern
AU - Emily K. Wiecek
AU - David K. Wallace
AU - Allison I. Summers
AU - Robert J. Henderson
AU - Wesley T. Beaulieu
AU - Raymond T. Kraker
AU - Stacy L. Pineles
AU - Katherine K. Weise
AU - Jonathan M. Holmes
AU - Susan A. Cotter
PY - 2026
DA - 2026/11/20
JO - Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
DO - 10.1007/s44402-026-00228-8
UR - https://doi.org/10.1007/s44402-026-00228-8
AB - PURPOSE: To evaluate the agreement and diagnostic utility of Nott Dynamic Retinoscopy (NDR) compared with instrument-based methods for assessing accommodative amplitude, accuracy and variability in children with unilateral amblyopia. METHODS: Children aged 5-10 years with unilateral amblyopia (6/12-6/30, N = 42) and without amblyopia (6/7.5 or better, N = 51) were enrolled. Accommodative parameters were assessed using NDR and instrument-based methods: Grand Seiko autorefractor for amplitude and accuracy and PowerRef 3 for variability. Participants monocularly viewed 6/45 letters on an iPod at 33 cm for accuracy and variability; the same letters were viewed at progressively closer test distances and through minus lenses for amplitude assessment. Agreement between NDR and instrument-based measures was evaluated using Bland-Altman analysis. Instrument-based values from controls established abnormal thresholds, defined as worse than the 1-sided 95% tolerance limits with 90% confidence. NDR cut-offs for detecting abnormal accommodation values were derived using receiver operating characteristic (ROC) curves. RESULTS: Agreement between NDR and instrument-based methods was poor for all accommodative parameters with wide limits of agreement. Based on instrument-based tolerance limits, 39% of amblyopic eyes had abnormal amplitude (≤6.63 D), 34% had abnormal accuracy (lag ≥2.12 D) and 7% had abnormal variability (≥0.98 D). For amplitude, an NDR cut-off ≤5.60 D provided 80% sensitivity (95% CI, 60-100%) and 80% specificity (95% CI, 64-96%) to detect abnormality (area under the ROC curve [AUROC] = 0.85). For accuracy, an NDR cut-off ≥1.55 D provided 92% sensitivity (95% CI, 76-100%) and 81% specificity (95% CI, 67-96%) (AUROC = 0.90). There were insufficient participants with abnormal accommodative variability using the PowerRef 3 to establish an NDR threshold. CONCLUSIONS: NDR is not interchangeable with instrument-based objective accommodative measures in children with and without amblyopia; however, it may be useful as a screening tool for abnormal accommodative amplitude and accuracy, pending confirmation in larger, independent cohorts.
SN - 0275-5408
SN - 1475-1313
ER -