Skip to content
DraconiticResearch
Search Sources API
190,839 studies31 sourcesUpdated 16 min ago
PreprintarXiv licencearXiv

Contact lens with stretchable distributed-feedback laser for intraocular pressure monitoring

Abstract

Continuous monitoring of intraocular pressure (IOP) is essential for the diagnosis and management of glaucoma, yet existing clinical methods rely on intermittent in-clinic measurements that miss critical diurnal fluctuations. Smart contact lenses are an attractive platform for continuous IOP tracking, and optical strain sensors are particularly promising thanks to their high sensitivity and natural readout. Most such optical sensors infer strain from the period of a regular structure - a grating or photonic crystal - whose deformation is read out optically. However, the precision of all sensors based on the period of regular structures is fundamentally bounded by the uncertainty principle, which severely limits performance at the millimeter length scales available inside a contact lens. Here, we address this limitation by integrating a distributed-feedback (DFB) laser, based on a surface-modulated ultrathin F8BT dye layer, into a soft polydimethylsiloxane (PDMS) contact lens. Operating at a symmetry-protected bound state in the continuum at the Γ point, the device produces a narrow lasing line whose wavelength shifts directly with grating strain - a quantity not constrained by the spatial uncertainty principle. The DFB structure is fabricated by UV holographic lithography and transferred onto the lens by a simple float-off process, yielding a stretchable, transparent, polymer-compatible sensor that is intrinsically scalable. Tested on a custom artificial eye model whose pressure-induced deformation is comparable in scale to that reported for the human eye, the sensor achieves a sensitivity of 0.027 nm/mmHg and a calibration residual of 1.2 mmHg under phantom conditions, a level relevant to tonometric monitoring, with substantial headroom currently limited mainly by auxiliary readout equipment.

Related

  1. Sub-10-ns single-frequency linearly polarized 2055-nm thulium-doped distributed-feedback fiber laser inscribed by femtosecond-laser direct writing
    Zhenzhen Zhang, Jindan Shi, Xian Feng
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  2. Time-domain traveling-wave simulations for generating near-transform-limited 1-ps pulses using gain-switched distributed-feedback lasers
    Fuyi Cao, Cong Wang, Yihan Qi +3
    Optics ExpressPeer-reviewedPublisher termsFull textOptics & photonicsCrossref
  3. Single-mode, distributed feedback interband cascade lasers grown on GaSb and GaAs substrates, emitting at 4.6 µm
    Lydia Kacel, Zeineb Loghmari, Daniel Dìaz-Thomas +5
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Distributed fiber optical multiparameter sensor combining three backscattering effects for structural health monitoring
    Korbinian Königsbauer, Xin Lu
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  5. Distinct Feedback-Strength Requirements for Quantum-State Ensemble Preparation under Channel-Equivalent Monitoring
    Haitao Huang, Qinglin Zhao, Xiaoyu Li
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
BibTeX
@misc{ivanov2026contact,
  title = {{Contact lens with stretchable distributed-feedback laser for intraocular pressure monitoring}},
  author = {S. A. Ivanov and I. M. Fradkin and E. S. Musikhina and R. V. Kirtaev and A. A. Khrebtov and A. A. Vyshnevyy and A. A. Marchenko and V. R. Solovei and I. P. Radko and A. V. Arsenin and V. S. Volkov},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.34476},
  eprint = {2609.34476},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.34476},
}
RIS
TY  - UNPB
TI  - Contact lens with stretchable distributed-feedback laser for intraocular pressure monitoring
AU  - S. A. Ivanov
AU  - I. M. Fradkin
AU  - E. S. Musikhina
AU  - R. V. Kirtaev
AU  - A. A. Khrebtov
AU  - A. A. Vyshnevyy
AU  - A. A. Marchenko
AU  - V. R. Solovei
AU  - I. P. Radko
AU  - A. V. Arsenin
AU  - V. S. Volkov
PY  - 2026
DA  - 2026/09/28
PB  - arXiv
DO  - 10.48550/arxiv.2609.34476
UR  - https://arxiv.org/abs/2609.34476
AB  - Continuous monitoring of intraocular pressure (IOP) is essential for the diagnosis and management of glaucoma, yet existing clinical methods rely on intermittent in-clinic measurements that miss critical diurnal fluctuations. Smart contact lenses are an attractive platform for continuous IOP tracking, and optical strain sensors are particularly promising thanks to their high sensitivity and natural readout. Most such optical sensors infer strain from the period of a regular structure - a grating or photonic crystal - whose deformation is read out optically. However, the precision of all sensors based on the period of regular structures is fundamentally bounded by the uncertainty principle, which severely limits performance at the millimeter length scales available inside a contact lens. Here, we address this limitation by integrating a distributed-feedback (DFB) laser, based on a surface-modulated ultrathin F8BT dye layer, into a soft polydimethylsiloxane (PDMS) contact lens. Operating at a symmetry-protected bound state in the continuum at the Γ point, the device produces a narrow lasing line whose wavelength shifts directly with grating strain - a quantity not constrained by the spatial uncertainty principle. The DFB structure is fabricated by UV holographic lithography and transferred onto the lens by a simple float-off process, yielding a stretchable, transparent, polymer-compatible sensor that is intrinsically scalable. Tested on a custom artificial eye model whose pressure-induced deformation is comparable in scale to that reported for the human eye, the sensor achieves a sensitivity of 0.027 nm/mmHg and a calibration residual of 1.2 mmHg under phantom conditions, a level relevant to tonometric monitoring, with substantial headroom currently limited mainly by auxiliary readout equipment.
ER  -