Diagnostic Performance of Artificial Intelligence for the Detection and Segmentation of Periapical Lesions on Cone-Beam Computed Tomography: A Systematic Review and Meta-Analysis
- 1Department of Endodontics, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80200, Jeddah 21589, Saudi Arabia
Abstract
Background/Objectives: Cone-beam computed tomography (CBCT) improves periapical lesion detection, but its interpretation is expertise-dependent. This systematic review evaluated artificial intelligence (AI) for detecting, classifying, and segmenting periapical lesions on CBCT. Methods: PubMed, the Cochrane Library, Scopus, Web of Science, and Google Scholar were searched to 12 December 2025 (PROSPERO: CRD420251184440). Studies comparing AI with an expert- or annotation-based reference standard on human CBCT scans were eligible. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, and certainty of evidence with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Sensitivity and specificity were pooled with a bivariate model where complete 2 × 2 data were available, and all metrics with univariate random-effects models. Results: Eighteen studies were included (detection or classification, 16; segmentation, 6); 15 had unclear risk of bias in at least one domain, and most were retrospective and internally validated. In the bivariate model (seven studies), sensitivity was 88.2% (95% confidence interval [CI]: 77.6–94.2%) and specificity 85.1% (73.4–92.1%). Univariate pooled sensitivity was 90.9% (84.2–94.9%; 14 studies), specificity 89.7% (83.2–93.9%; 11 studies), accuracy 86.7% (78.9–92.0%; 10 studies), and F1-score 83.7% (76.4–89.1%; seven studies). The pooled lesion Dice similarity coefficient was 0.70 (0.61–0.78; six studies), indicating moderate spatial overlap with reference annotations. Heterogeneity was considerable for detection metrics (I2 = 90–96%), prediction intervals were wide (sensitivity 48–99%), and the certainty of evidence was very low. Conclusions: AI shows promising performance for CBCT-based periapical lesion detection under research conditions, whereas segmentation overlap is moderate. Equivalence to clinicians and clinical effectiveness are not established; prospective, externally validated studies with standardized reference standards are needed.
Related
- CT-Referenced Diagnostic Performance and Complementary Error Patterns of Artificial Intelligence Versus a Single Emergency Physician in Chest Radiograph Interpretation: A Retrospective Paired Diagnostic Accuracy Study
- From underdiagnosis to scalable screening: Applications of artificial intelligence for vertebral compression fracture detection – a systematic review and meta-analysis of diagnostic performance
- Diagnostic performance and clinical integration of an artificial intelligence–assisted ultrasound decision support tool for thyroid nodules at a tertiary cancer centre
- Diagnostic Performance of Multimodal Artificial Intelligence in Differentiating Ocular Surface Squamous Neoplasia from Benign Lesions: A Retrospective Diagnostic Accuracy Study
- Performance Assessment of an Artificial Intelligence System Used for Case Detection in a Large Community-based Diabetic Retinopathy Screening Program: A Retrospective Diagnostic Accuracy Validation Study.
BibTeX
@article{howait2026diagnostic,
title = {{Diagnostic Performance of Artificial Intelligence for the Detection and Segmentation of Periapical Lesions on Cone-Beam Computed Tomography: A Systematic Review and Meta-Analysis}},
author = {Mohammed Howait and Mey A. Al-Habib},
journal = {Diagnostics},
year = {2026},
month = nov,
doi = {10.3390/diagnostics16213606},
url = {https://doi.org/10.3390/diagnostics16213606},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Diagnostic Performance of Artificial Intelligence for the Detection and Segmentation of Periapical Lesions on Cone-Beam Computed Tomography: A Systematic Review and Meta-Analysis
AU - Mohammed Howait
AU - Mey A. Al-Habib
PY - 2026
DA - 2026/11/01
JO - Diagnostics
DO - 10.3390/diagnostics16213606
UR - https://doi.org/10.3390/diagnostics16213606
AB - Background/Objectives: Cone-beam computed tomography (CBCT) improves periapical lesion detection, but its interpretation is expertise-dependent. This systematic review evaluated artificial intelligence (AI) for detecting, classifying, and segmenting periapical lesions on CBCT. Methods: PubMed, the Cochrane Library, Scopus, Web of Science, and Google Scholar were searched to 12 December 2025 (PROSPERO: CRD420251184440). Studies comparing AI with an expert- or annotation-based reference standard on human CBCT scans were eligible. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, and certainty of evidence with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Sensitivity and specificity were pooled with a bivariate model where complete 2 × 2 data were available, and all metrics with univariate random-effects models. Results: Eighteen studies were included (detection or classification, 16; segmentation, 6); 15 had unclear risk of bias in at least one domain, and most were retrospective and internally validated. In the bivariate model (seven studies), sensitivity was 88.2% (95% confidence interval [CI]: 77.6–94.2%) and specificity 85.1% (73.4–92.1%). Univariate pooled sensitivity was 90.9% (84.2–94.9%; 14 studies), specificity 89.7% (83.2–93.9%; 11 studies), accuracy 86.7% (78.9–92.0%; 10 studies), and F1-score 83.7% (76.4–89.1%; seven studies). The pooled lesion Dice similarity coefficient was 0.70 (0.61–0.78; six studies), indicating moderate spatial overlap with reference annotations. Heterogeneity was considerable for detection metrics (I2 = 90–96%), prediction intervals were wide (sensitivity 48–99%), and the certainty of evidence was very low. Conclusions: AI shows promising performance for CBCT-based periapical lesion detection under research conditions, whereas segmentation overlap is moderate. Equivalence to clinicians and clinical effectiveness are not established; prospective, externally validated studies with standardized reference standards are needed.
SN - 2075-4418
ER -