Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 6 min ago
Peer-reviewedCC BY 4.0Diagnostics

Diagnostic Performance of Artificial Intelligence for the Detection and Segmentation of Periapical Lesions on Cone-Beam Computed Tomography: A Systematic Review and Meta-Analysis

  1. 1Department of Endodontics, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80200, Jeddah 21589, Saudi Arabia

Abstract

Background/Objectives: Cone-beam computed tomography (CBCT) improves periapical lesion detection, but its interpretation is expertise-dependent. This systematic review evaluated artificial intelligence (AI) for detecting, classifying, and segmenting periapical lesions on CBCT. Methods: PubMed, the Cochrane Library, Scopus, Web of Science, and Google Scholar were searched to 12 December 2025 (PROSPERO: CRD420251184440). Studies comparing AI with an expert- or annotation-based reference standard on human CBCT scans were eligible. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, and certainty of evidence with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Sensitivity and specificity were pooled with a bivariate model where complete 2 × 2 data were available, and all metrics with univariate random-effects models. Results: Eighteen studies were included (detection or classification, 16; segmentation, 6); 15 had unclear risk of bias in at least one domain, and most were retrospective and internally validated. In the bivariate model (seven studies), sensitivity was 88.2% (95% confidence interval [CI]: 77.6–94.2%) and specificity 85.1% (73.4–92.1%). Univariate pooled sensitivity was 90.9% (84.2–94.9%; 14 studies), specificity 89.7% (83.2–93.9%; 11 studies), accuracy 86.7% (78.9–92.0%; 10 studies), and F1-score 83.7% (76.4–89.1%; seven studies). The pooled lesion Dice similarity coefficient was 0.70 (0.61–0.78; six studies), indicating moderate spatial overlap with reference annotations. Heterogeneity was considerable for detection metrics (I2 = 90–96%), prediction intervals were wide (sensitivity 48–99%), and the certainty of evidence was very low. Conclusions: AI shows promising performance for CBCT-based periapical lesion detection under research conditions, whereas segmentation overlap is moderate. Equivalence to clinicians and clinical effectiveness are not established; prospective, externally validated studies with standardized reference standards are needed.

Related

  1. CT-Referenced Diagnostic Performance and Complementary Error Patterns of Artificial Intelligence Versus a Single Emergency Physician in Chest Radiograph Interpretation: A Retrospective Paired Diagnostic Accuracy Study
    Ömer Damar, Mahmut Yaman
    TomographyPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  2. From underdiagnosis to scalable screening: Applications of artificial intelligence for vertebral compression fracture detection – a systematic review and meta-analysis of diagnostic performance
    Hsuan-Yu Chen, Linjun Yang, Gwen Wilson +4
    Osteoporosis and sarcopeniaPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Diagnostic performance and clinical integration of an artificial intelligence–assisted ultrasound decision support tool for thyroid nodules at a tertiary cancer centre
    Wyanne Law, Junting Zheng, Shannan M. Dickinson +6
    Ultrasound: Journal of the British Medical Ultrasound SocietyPeer-reviewedLicence not statedFull textEndocrinology & metabolismPMC
  4. Diagnostic Performance of Multimodal Artificial Intelligence in Differentiating Ocular Surface Squamous Neoplasia from Benign Lesions: A Retrospective Diagnostic Accuracy Study
    Laura De Luca, Feliciana Menna, Stefano Lupo +4
    DiagnosticsPeer-reviewedCC BY 4.0Full textEpidemiology & public healthPMC
  5. Performance Assessment of an Artificial Intelligence System Used for Case Detection in a Large Community-based Diabetic Retinopathy Screening Program: A Retrospective Diagnostic Accuracy Validation Study.
    Maria Kristina Dg Eduardo, Junn R Pajarillo
    Acta medica PhilippinaPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMCPMC
BibTeX
@article{howait2026diagnostic,
  title = {{Diagnostic Performance of Artificial Intelligence for the Detection and Segmentation of Periapical Lesions on Cone-Beam Computed Tomography: A Systematic Review and Meta-Analysis}},
  author = {Mohammed Howait and Mey A. Al-Habib},
  journal = {Diagnostics},
  year = {2026},
  month = nov,
  doi = {10.3390/diagnostics16213606},
  url = {https://doi.org/10.3390/diagnostics16213606},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Diagnostic Performance of Artificial Intelligence for the Detection and Segmentation of Periapical Lesions on Cone-Beam Computed Tomography: A Systematic Review and Meta-Analysis
AU  - Mohammed Howait
AU  - Mey A. Al-Habib
PY  - 2026
DA  - 2026/11/01
JO  - Diagnostics
DO  - 10.3390/diagnostics16213606
UR  - https://doi.org/10.3390/diagnostics16213606
AB  - Background/Objectives: Cone-beam computed tomography (CBCT) improves periapical lesion detection, but its interpretation is expertise-dependent. This systematic review evaluated artificial intelligence (AI) for detecting, classifying, and segmenting periapical lesions on CBCT. Methods: PubMed, the Cochrane Library, Scopus, Web of Science, and Google Scholar were searched to 12 December 2025 (PROSPERO: CRD420251184440). Studies comparing AI with an expert- or annotation-based reference standard on human CBCT scans were eligible. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, and certainty of evidence with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Sensitivity and specificity were pooled with a bivariate model where complete 2 × 2 data were available, and all metrics with univariate random-effects models. Results: Eighteen studies were included (detection or classification, 16; segmentation, 6); 15 had unclear risk of bias in at least one domain, and most were retrospective and internally validated. In the bivariate model (seven studies), sensitivity was 88.2% (95% confidence interval [CI]: 77.6–94.2%) and specificity 85.1% (73.4–92.1%). Univariate pooled sensitivity was 90.9% (84.2–94.9%; 14 studies), specificity 89.7% (83.2–93.9%; 11 studies), accuracy 86.7% (78.9–92.0%; 10 studies), and F1-score 83.7% (76.4–89.1%; seven studies). The pooled lesion Dice similarity coefficient was 0.70 (0.61–0.78; six studies), indicating moderate spatial overlap with reference annotations. Heterogeneity was considerable for detection metrics (I2 = 90–96%), prediction intervals were wide (sensitivity 48–99%), and the certainty of evidence was very low. Conclusions: AI shows promising performance for CBCT-based periapical lesion detection under research conditions, whereas segmentation overlap is moderate. Equivalence to clinicians and clinical effectiveness are not established; prospective, externally validated studies with standardized reference standards are needed.
SN  - 2075-4418
ER  -