Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 35 min ago
Peer-reviewedCC BY 4.0Journal of Vascular Surgery Cases, Innovations and Techniques

Impact of intravascular ultrasound guidance on radiation exposure during endovascular abdominal aortic aneurysm repair: Single-center experience

  1. 1Department of Vascular Surgery, University Hospitals of Coventry and Warwickshire, Coventry, West Midlands, UK
  2. 2Department of Radiology Physics, University Hospitals of Coventry and Warwickshire, Coventry, West Midlands, UK

Abstract

Objective: To assess the effect of using intravascular ultrasound (IVUS) in endovascular aortic aneurysms repair (EVAR) on reduction of radiation exposure.

Methods: All EVAR procedures performed for symptomatic and asymptomatic infrarenal abdominal aortic aneurysms at a single U.K. center between January 2024 and December 2025 were retrospectively analyzed. Patients were divided into two groups based on imaging guidance used: IVUS-guided EVAR and standard EVAR. The primary end points were radiation dose and fluoroscopy time (FT), whereas the secondary outcomes included intraoperative technical success, change in pre- and postoperative serum creatinine level length of hospital stay, and 30-day morbidity and mortality.

Results: During the study period, 51 patients met inclusion criteria at our center, 30 patients (58.8%) had standard EVAR procedure with fluoroscopy-guidance, whereas 21 patients (41.2%) had IVUS-guided EVAR procedure. Median dose area product in standard EVAR cases was 45.24 Gy cm2 compared with 7.27 Gy cm2 in IVUS-guided EVAR cases (P <.001, highly significant), and median FT in standard EVAR cases was 15.4 minutes compared with 4.5 minutes in IVUS-guided EVAR cases (P <.001, highly significant). Intraoperative technical success achieved in 19 patients (90%) in IVUS-guided cases compared with 28 patients (93%) in standard EVAR cases. The mean postoperative creatinine level was 71.4 ± 16.7 μmol/L in patients who underwent IVUS-guided EVAR cases, compared with 86.0 ± 22.0 μmol/L in patients with standard EVAR.

Conclusions: IVUS provides accurate and safe graft deployment while reducing the total radiation dose and FT. This significantly reduces the radiation risks to patients and staff while maintaining the highest patient care and procedure safety.

Related

  1. Intravascular Ultrasound (IVUS)-Assisted Fenestrated Endovascular Aortic Repair (FEVAR) for Iuxtarenal Aortic Aneurysm with Pelvic Ectopic Left Kidney and Aberrant Left Renal Arteries: A Case Report.
    Priscilla Nardi, Giulia Guadalupi, Valerio Rinaldi +12
    Reports (MDPI)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Intravascular ultrasound-guided versus angiography-guided endovascular interventions for peripheral artery disease: a systematic review and meta-analysis.
    Montserrat Villa Sanchez, Ruth Alejandra Diaz Revelo, Maya AlQawasmi +9
    BMC cardiovascular disordersPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  3. Surgical, endovascular, and systemic management of renal cell carcinoma with intravascular recurrence
    Davis Temple, Megan K.H. Powell, Linda W. Martin +5
    Urology case reportsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Intravascular Prevotella copri promotes the formation of abdominal aortic aneurysm by enhancing TPX2 lactylation
    Jie Xiao, Chenghao Li, Yuan Zhou +8
    BMC MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  5. Intravascular lithotripsy for calcific stenosis of the abdominal aorta in a patient with Takayasu arteritis
    John H. Cabot, Mary Cain, Arash Fereydooni +1
    Journal of Vascular Surgery Cases, Innovations and TechniquesPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
BibTeX
@article{shehata2026impact,
  title = {{Impact of intravascular ultrasound guidance on radiation exposure during endovascular abdominal aortic aneurysm repair: Single-center experience}},
  author = {Mahetab Shehata and Ahmed Elshiekh and Asif Mahmood and Nicholas Matharu and Ahmed Hassan and Chris Koller and Ashraf Elsharkawy},
  journal = {Journal of Vascular Surgery Cases, Innovations and Techniques},
  year = {2026},
  month = oct,
  doi = {10.1016/j.jvscit.2026.102548},
  url = {https://doi.org/10.1016/j.jvscit.2026.102548},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Impact of intravascular ultrasound guidance on radiation exposure during endovascular abdominal aortic aneurysm repair: Single-center experience
AU  - Mahetab Shehata
AU  - Ahmed Elshiekh
AU  - Asif Mahmood
AU  - Nicholas Matharu
AU  - Ahmed Hassan
AU  - Chris Koller
AU  - Ashraf Elsharkawy
PY  - 2026
DA  - 2026/10/07
JO  - Journal of Vascular Surgery Cases, Innovations and Techniques
DO  - 10.1016/j.jvscit.2026.102548
UR  - https://doi.org/10.1016/j.jvscit.2026.102548
AB  - Objective: To assess the effect of using intravascular ultrasound (IVUS) in endovascular aortic aneurysms repair (EVAR) on reduction of radiation exposure.  Methods: All EVAR procedures performed for symptomatic and asymptomatic infrarenal abdominal aortic aneurysms at a single U.K. center between January 2024 and December 2025 were retrospectively analyzed. Patients were divided into two groups based on imaging guidance used: IVUS-guided EVAR and standard EVAR. The primary end points were radiation dose and fluoroscopy time (FT), whereas the secondary outcomes included intraoperative technical success, change in pre- and postoperative serum creatinine level length of hospital stay, and 30-day morbidity and mortality.  Results: During the study period, 51 patients met inclusion criteria at our center, 30 patients (58.8%) had standard EVAR procedure with fluoroscopy-guidance, whereas 21 patients (41.2%) had IVUS-guided EVAR procedure. Median dose area product in standard EVAR cases was 45.24 Gy cm2 compared with 7.27 Gy cm2 in IVUS-guided EVAR cases (P <.001, highly significant), and median FT in standard EVAR cases was 15.4 minutes compared with 4.5 minutes in IVUS-guided EVAR cases (P <.001, highly significant). Intraoperative technical success achieved in 19 patients (90%) in IVUS-guided cases compared with 28 patients (93%) in standard EVAR cases. The mean postoperative creatinine level was 71.4 ± 16.7 μmol/L in patients who underwent IVUS-guided EVAR cases, compared with 86.0 ± 22.0 μmol/L in patients with standard EVAR.  Conclusions: IVUS provides accurate and safe graft deployment while reducing the total radiation dose and FT. This significantly reduces the radiation risks to patients and staff while maintaining the highest patient care and procedure safety.
SN  - 2468-4287
ER  -