Ultra low-dose fluoroscopy in chronic total occlusion PCI: a preliminary feasibility study
- 1Department of Cardiology, County Hospital Cakovec, Cakovec, Croatia
- 2Department of Invasive Cardiology, Humanitas Research Hospital IRCCS, Rozzano, Milan, Italy
- 3Division of Interventional Cardiology and Ischemic Heart Disease, Department of Cardiovascular Diseases, University Hospital of Split (KBC Split), Split, Croatia
Abstract
To the Editor, Chronic total occlusion (CTO) percutaneous coronary intervention (PCI) is among the most radiation-intensive coronary procedures, owing to high lesion complexity, use of dual injections, and prolonged wire manipulation and/or retrograde techniques, all of which increase fluoroscopy time and cine acquisition. Contemporary data indicate that median patient radiation exposure, measured as air kerma (AK) remains substantial in CTO PCI (median, 2.3 Gy); however, this has been in decline recently due to improvements in equipment and procedural techniques.1 From the patient standpoint, transient tissue reactions usually occur when absorbed radiation skin dose exceeds 2 Gy while permanent effects occur in absorbed doses > 5 Gy.2 For operators, cumulative scatter radiation exposure to the eyes, head, and torso underscores the need to improve shielding and workflow to reduce occupational exposure.3 Importantly, a large multicenter analysis showed that education, equipment optimization, and procedural discipline can significantly decrease radiation exposure without compromising procedural success.4 Similarly, a previously published report from our research group showed that an ultra-low-dose (ULD) fluoroscopy protocol significantly reduces radiation exposure during CTO PCI.5 Accordingly, we sought to evaluate the feasibility of implementing a ULD fluoroscopy workflow during CTO PCI procedures at a single-center institution. We conducted a retrospective analysis of...
Related
- Ultra low-dose fluoroscopy in chronic total occlusion PCI: a preliminary feasibility study Fluoroscopia de dosis ultrabaja en la ICP de oclusión total crónica: un estudio preliminar de viabilidad
- FEASIBILITY, SAFETY, AND PRELIMINARY EFFECTS OF HAPTIC CANE-ASSISTED GAIT TRAINING IN CHRONIC HEMIPARETIC STROKE: A PILOT RANDOMIZED CROSSOVER TRIAL
- Tele-based ischemic conditioning for chronic stroke: Safety, feasibility, and preliminary neurophysiological and motor effects
- Feasibility and Safety of Transthoracic Echocardiography–Guided Transvenous Permanent Pacemaker Implantation Without Fluoroscopy
- Technical feasibility of synchronized multispectral dual-site optical sensing during vascular occlusion in an acute porcine flap model
BibTeX
@article{kovacic2026ultra,
title = {{Ultra low-dose fluoroscopy in chronic total occlusion PCI: a preliminary feasibility study}},
author = {Mihajlo Kovacic and Mateja Ostricki and Gabrielle L. Gasparini and Josip Andelo Borovac},
journal = {REC: Interventional Cardiology (English Ed.)},
year = {2026},
month = nov,
doi = {10.24875/recice.m26000586},
url = {https://doi.org/10.24875/recice.m26000586},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Ultra low-dose fluoroscopy in chronic total occlusion PCI: a preliminary feasibility study
AU - Mihajlo Kovacic
AU - Mateja Ostricki
AU - Gabrielle L. Gasparini
AU - Josip Andelo Borovac
PY - 2026
DA - 2026/11/10
JO - REC: Interventional Cardiology (English Ed.)
DO - 10.24875/recice.m26000586
UR - https://doi.org/10.24875/recice.m26000586
AB - To the Editor, Chronic total occlusion (CTO) percutaneous coronary intervention (PCI) is among the most radiation-intensive coronary procedures, owing to high lesion complexity, use of dual injections, and prolonged wire manipulation and/or retrograde techniques, all of which increase fluoroscopy time and cine acquisition. Contemporary data indicate that median patient radiation exposure, measured as air kerma (AK) remains substantial in CTO PCI (median, 2.3 Gy); however, this has been in decline recently due to improvements in equipment and procedural techniques.1 From the patient standpoint, transient tissue reactions usually occur when absorbed radiation skin dose exceeds 2 Gy while permanent effects occur in absorbed doses > 5 Gy.2 For operators, cumulative scatter radiation exposure to the eyes, head, and torso underscores the need to improve shielding and workflow to reduce occupational exposure.3 Importantly, a large multicenter analysis showed that education, equipment optimization, and procedural discipline can significantly decrease radiation exposure without compromising procedural success.4 Similarly, a previously published report from our research group showed that an ultra-low-dose (ULD) fluoroscopy protocol significantly reduces radiation exposure during CTO PCI.5 Accordingly, we sought to evaluate the feasibility of implementing a ULD fluoroscopy workflow during CTO PCI procedures at a single-center institution. We conducted a retrospective analysis of...
SN - 2604-7322
ER -