Absolute Agreement Between a Consumer Wearable and Research Grade Accelerometry in Free-Living Conditions: Comparison Study.
- 1Department of Community Medicine, UiT The Arctic University of Norway, Hansine Hansens veg 78, Tromsø, 9019, Norway, 47 77646088.
- 2Department of Computer Science, UiT The Arctic University of Norway, TROMSØ, Troms, Norway.
- 3School of Sport Sciences, UiT The Arctic University of Norway, TROMSØ, Troms, Norway.
Abstract
Research-grade accelerometers are widely used to monitor physical activity in research but are often expensive, have limited battery and storage, and impose a high participant burden. Consumer wearables are designed for long-term monitoring and are being extensively used in research. However, evidence regarding their accuracy remains inconsistent. This study aimed to examine agreement between the Garmin Forerunner 55 and the ActiGraph wGT3X-BT for steps, moderate-to-vigorous physical activity (MVPA), and activity energy expenditure (AEE) in older adults under free-living conditions. We included baseline data from 82 community-dwelling older adults (60-75 years) in the RESTART (Re-Inventing Strategies for Healthy Ageing; Recommendations and Tools) trial who wore the ActiGraph wGT3X-BT and the Garmin Forerunner 55 simultaneously for 3 to 7 days. Valid days were defined as ≥10 hours of wear time per day. We compared mean steps, MVPA, and AEE between devices. Agreement was examined using intraclass correlation coefficients (ICCs) and Bland-Altman plots. The Garmin Forerunner 55 recorded 990 (limits of agreement [LoA] -1123 to 3104) steps/day more than the ActiGraph wGT3X-BT with an ICC of 0.81, indicating good agreement but with substantial uncertainty due to the wide CI (95% CI 0.34-0.92). For AEE, the Garmin device reported 41.8 kcal/day lower values, with poor agreement (ICC=0.31; LoA -582.9 to 499.4 kcal/day). MVPA showed the largest discrepancy, with the Garmin device recording 23 minutes/day less and poor agreement (ICC=0.17; LoA -86.7 to 40.6 minutes/day). Bland-Altman plots indicated proportional bias across all metrics. In older adults with low activity levels, the Garmin Forerunner 55 demonstrated good agreement for daily step count but poor agreement for AEE and MVPA compared with the ActiGraph wGT3X-BT. Consumer devices such as the Garmin Forerunner 55 may be suitable for the monitoring of step-based metrics at the group level, but intensity-based measures should be interpreted with caution.
Related
- Accelerometry-based comparison of functional outcomes across total and partial knee and hip arthroplasty : a propensity-matched UK Biobank Study
- Method comparison and agreement of a fluorescence immunoassay-based HbA1c test with a routine HPLC method
- Agreement between a wrist-worn solar-powered watch and a chest-mounted light logger in quantifying daily time above 1500 lx in children: a pilot field comparison study
- Bench Agreement of Two Units of a Low-Cost Digital Manometers with a Clinical Respiratory Pressure Comparator: A Laboratory-Based Comparison
- Safety boundary maintenance in consumer AI systems responding to pediatric health queries: a cross-platform benchmark evaluation under naturalistic and adversarially pressured conditions
BibTeX
@article{hagerupsen2026absolute,
title = {{Absolute Agreement Between a Consumer Wearable and Research Grade Accelerometry in Free-Living Conditions: Comparison Study.}},
author = {Karianne Hagerupsen and André Henriksen and Bente Morseth and Sameline Grimsgaard and Jonas Johansson},
journal = {JMIR formative research},
year = {2026},
month = nov,
doi = {10.2196/105610},
url = {https://europepmc.org/article/MED/43083909},
note = {CC BY},
}
RIS
TY - JOUR
TI - Absolute Agreement Between a Consumer Wearable and Research Grade Accelerometry in Free-Living Conditions: Comparison Study.
AU - Karianne Hagerupsen
AU - André Henriksen
AU - Bente Morseth
AU - Sameline Grimsgaard
AU - Jonas Johansson
PY - 2026
DA - 2026/11/24
JO - JMIR formative research
DO - 10.2196/105610
UR - https://europepmc.org/article/MED/43083909
AB - Research-grade accelerometers are widely used to monitor physical activity in research but are often expensive, have limited battery and storage, and impose a high participant burden. Consumer wearables are designed for long-term monitoring and are being extensively used in research. However, evidence regarding their accuracy remains inconsistent. This study aimed to examine agreement between the Garmin Forerunner 55 and the ActiGraph wGT3X-BT for steps, moderate-to-vigorous physical activity (MVPA), and activity energy expenditure (AEE) in older adults under free-living conditions. We included baseline data from 82 community-dwelling older adults (60-75 years) in the RESTART (Re-Inventing Strategies for Healthy Ageing; Recommendations and Tools) trial who wore the ActiGraph wGT3X-BT and the Garmin Forerunner 55 simultaneously for 3 to 7 days. Valid days were defined as ≥10 hours of wear time per day. We compared mean steps, MVPA, and AEE between devices. Agreement was examined using intraclass correlation coefficients (ICCs) and Bland-Altman plots. The Garmin Forerunner 55 recorded 990 (limits of agreement [LoA] -1123 to 3104) steps/day more than the ActiGraph wGT3X-BT with an ICC of 0.81, indicating good agreement but with substantial uncertainty due to the wide CI (95% CI 0.34-0.92). For AEE, the Garmin device reported 41.8 kcal/day lower values, with poor agreement (ICC=0.31; LoA -582.9 to 499.4 kcal/day). MVPA showed the largest discrepancy, with the Garmin device recording 23 minutes/day less and poor agreement (ICC=0.17; LoA -86.7 to 40.6 minutes/day). Bland-Altman plots indicated proportional bias across all metrics. In older adults with low activity levels, the Garmin Forerunner 55 demonstrated good agreement for daily step count but poor agreement for AEE and MVPA compared with the ActiGraph wGT3X-BT. Consumer devices such as the Garmin Forerunner 55 may be suitable for the monitoring of step-based metrics at the group level, but intensity-based measures should be interpreted with caution.
SN - 2561-326X
ER -