A high-fidelity physical simulator as a feasible assessment tool for evaluating percutaneous transforaminal endoscopic discectomy skills.
7 affiliations
- 1Department of Industrial and Product Design, Sichuan Fine Arts Institute, Chongqing, China.
- 2Department of Computer Science and Artificial Intelligence, Wuhan University of Technology, Wuhan, China.
- 3Department of Digital Media Art, Sichuan Fine Arts Institute, Chongqing, China.
- 4Department of Design, Huazhong University of Science and Technology, Wuhan, China.
- 5Chongqing Medical University, Chongqing, China.
- 6Department of Orthopaedic Surgery, Chongqing Municipal Health Commission Key Laboratory of Musculoskeletal Regeneration and Translational Medicine/Orthopaedic Research Laboratory, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China. [email protected].
- 7Department of Orthopaedic Surgery, Nanchuan Hospital of Chongqing Medical University, 16 Nan Da Road, Chongqing, China. [email protected].
Abstract
Background
Percutaneous transforaminal endoscopic discectomy (PTED) is an increasingly popular technique for treating symptomatic lumbar disc herniation (LDH) worldwide. However, performing PTED demands a high level of surgical proficiency, which can only be achieved through structured and extensive training. Current training methods remain inadequate for equipping novice surgeons.Methods
By integrating medical image reconstruction, computer-aided design (CAD), programming, and three-dimensional (3D) printing, a high-fidelity physical simulator with interactive features was developed. An exploratory cross-sectional study involving 19 neurosurgeons and trainees was conducted to examine the preliminary feasibility of the simulator for assessing PTED portal-placement performance. Participants were categorized into three subgroups based on their prior PTED experience. Each participant then performed the simulated portal placement procedure on the simulator. Performance was evaluated using a task-specific checklist, a global rating scale (GRS), and key objective metrics. Participant feedback on the training experience and the simulator itself was collected via a participant feedback survey.Results
Significant between-group differences were observed in task-specific checklist scores [F(2,16) = 32.05, P < 0.001, η² = 0.800, 95% confidence interval (CI) 0.628-0.892], GRS scores [F(2,16) = 18.30, P < 0.001, η² = 0.696, 95% CI 0.412-0.841], procedural duration [F(2,16) = 8.131, P = 0.004, η² = 0.504, 95% CI 0.150-0.726], and fluoroscopy count [F(2,16) = 5.162, P = 0.019, η² = 0.392, 95% CI 0.026-0.633]. Kruskal-Wallis sensitivity analyses supported the checklist and GRS findings. Alarm activation counts did not differ significantly among groups (H = 2.46, P = 0.293). Clinical experience was positively associated with checklist and GRS scores in exploratory Spearman analyses.Conclusion
This study presents a novel approach to developing a high-fidelity physical simulator for PTED training. The simulator distinguished participants across prior PTED experience levels in this exploratory cohort, providing preliminary evidence of its feasibility for assessing portal-placement performance. Favorable participant feedback also suggests its potential application in PTED training.
Related
- How reliable is percutaneous transforaminal endoscopic discectomy during the learning curve? A comparison of outcomes with microsurgical discectomy experiences
- The extent of intervertebral disc removal is associated with the occurrence of Modic change after percutaneous endoscopic transforaminal discectomy
- The clinical efficacy of magnetic resonance neurography-assisted percutaneous transforaminal endoscopic discectomy.
- Two-Dimensional Electromagnetic Navigation-Assisted Percutaneous Transforaminal Endoscopic Discectomy for Lumbar Disc Herniation: A Retrospective Comparative Study.
- A Commentary on “Interlaminar Versus Transforaminal Full-Endoscopic Lumbar Discectomy for Lumbar Disc Herniation: A Structured Debate and International Practice Patterns”
BibTeX
@article{cai2026highfidelity,
title = {{A high-fidelity physical simulator as a feasible assessment tool for evaluating percutaneous transforaminal endoscopic discectomy skills.}},
author = {Bohong Cai and Zihan Wang and Xinlu Yang and Yiran Qiao and Xi Lyu and Yuhan Liu and Qi Yao and Baixiang Chen and Jie Hao and Wei Jiang},
journal = {BMC musculoskeletal disorders},
year = {2026},
month = oct,
doi = {10.1186/s12891-026-10630-5},
url = {https://europepmc.org/article/MED/43079409},
note = {CC BY},
}
RIS
TY - JOUR
TI - A high-fidelity physical simulator as a feasible assessment tool for evaluating percutaneous transforaminal endoscopic discectomy skills.
AU - Bohong Cai
AU - Zihan Wang
AU - Xinlu Yang
AU - Yiran Qiao
AU - Xi Lyu
AU - Yuhan Liu
AU - Qi Yao
AU - Baixiang Chen
AU - Jie Hao
AU - Wei Jiang
PY - 2026
DA - 2026/10/21
JO - BMC musculoskeletal disorders
DO - 10.1186/s12891-026-10630-5
UR - https://europepmc.org/article/MED/43079409
AB - Background Percutaneous transforaminal endoscopic discectomy (PTED) is an increasingly popular technique for treating symptomatic lumbar disc herniation (LDH) worldwide. However, performing PTED demands a high level of surgical proficiency, which can only be achieved through structured and extensive training. Current training methods remain inadequate for equipping novice surgeons.Methods By integrating medical image reconstruction, computer-aided design (CAD), programming, and three-dimensional (3D) printing, a high-fidelity physical simulator with interactive features was developed. An exploratory cross-sectional study involving 19 neurosurgeons and trainees was conducted to examine the preliminary feasibility of the simulator for assessing PTED portal-placement performance. Participants were categorized into three subgroups based on their prior PTED experience. Each participant then performed the simulated portal placement procedure on the simulator. Performance was evaluated using a task-specific checklist, a global rating scale (GRS), and key objective metrics. Participant feedback on the training experience and the simulator itself was collected via a participant feedback survey.Results Significant between-group differences were observed in task-specific checklist scores [F(2,16) = 32.05, P < 0.001, η² = 0.800, 95% confidence interval (CI) 0.628-0.892], GRS scores [F(2,16) = 18.30, P < 0.001, η² = 0.696, 95% CI 0.412-0.841], procedural duration [F(2,16) = 8.131, P = 0.004, η² = 0.504, 95% CI 0.150-0.726], and fluoroscopy count [F(2,16) = 5.162, P = 0.019, η² = 0.392, 95% CI 0.026-0.633]. Kruskal-Wallis sensitivity analyses supported the checklist and GRS findings. Alarm activation counts did not differ significantly among groups (H = 2.46, P = 0.293). Clinical experience was positively associated with checklist and GRS scores in exploratory Spearman analyses.Conclusion This study presents a novel approach to developing a high-fidelity physical simulator for PTED training. The simulator distinguished participants across prior PTED experience levels in this exploratory cohort, providing preliminary evidence of its feasibility for assessing portal-placement performance. Favorable participant feedback also suggests its potential application in PTED training.
SN - 1471-2474
ER -