Skip to content
DraconiticResearch
Search Sources API
226,742 studies31 sourcesUpdated 52 min ago
Peer-reviewedCC BY 4.0Cardiology Research and Practice

From Catheters to Wearables: Advanced Hemodynamic Monitoring and the Emerging Role of PPG‐Based Devices

  1. 1Hadassah Medical Center and Faculty of Medicine Heart Institute Hebrew University of Jerusalem Jerusalem Israel huji.ac.il
  2. 2Department of Military Medicine Faculty of Medicine Institute for Research in Military Medicine The Hebrew University of Jerusalem Jerusalem Israel huji.ac.il
  3. 3Israel Defense Forces Medical Corps Tel Hashomer Ramat Gan Israel

Abstract

Advanced hemodynamic monitoring, including cardiac output (CO), stroke volume (SV), and systemic vascular resistance (SVR), is important for the management of cardiogenic shock, postoperative patients, and heart failure. Traditional approaches such as pulmonary artery catheterization (PAC) provide comprehensive hemodynamic assessment but are invasive, costly, and associated with procedure‐related risks. This review summarizes established invasive and minimally invasive techniques alongside emerging noninvasive approaches, including pulse contour analysis, bioimpedance, pulse wave transit time, and photoplethysmography (PPG)‐based systems. Particular emphasis is placed on PPG‐based technologies, which combine pulse wave analysis, pulse wave transit time, and advanced signal processing to estimate blood pressure and flow‐related parameters. As a representative case study, the clinical development and evaluation of the Biobeat BB‐613WP wearable are described, including preclinical swine hemorrhagic shock models, intensive care and perioperative validation against invasive reference methods, and ambulatory blood pressure monitoring studies. Available evidence suggests that PPG‐based wearables can achieve clinically acceptable agreement with invasive reference methods in selected populations while offering the potential for continuous, noninvasive, and ambulatory monitoring. However, the available evidence is limited by small sample sizes, single‐center studies, controlled conditions, and limited independent validation. Further multicenter, outcome‐oriented studies are required to establish the clinical role of PPG‐based devices across diverse patient populations and stages of care.

Related

  1. Effects of Pulmonary Vein Isolation on Left Atrial Hemodynamic and Mechanical Function: Insights from Advanced and Emerging Echocardiographic Parameters in Responders and Non-Responders
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Innovations and Challenges in Smart-Textile Wearables for Postural Monitoring: A Scoping Review
    Inês Peixoto, Carla Silvia Fernandes, Marta Campos Ferreira
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  3. Agreement between Garmin and Ultrahuman wearables and their association with continuous glucose monitoring: an n-of-1 study
    M. Lovric, D. Strbad, M. A. Rasmussen
    bioRxivPreprintCC BYFull textPhysiologybioRxiv
  4. Personalized Remote Patient Management in Heart Failure : From Implanted Hemodynamic Monitoring Toward an Artificial Intelligence-Supported Adaptive Care Cycle.
    Christiane E Angermann, Folkert W Asselbergs, Georg Ertl +1
    Current heart failure reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  5. Clinical utility of microaxial flow pump fiber-optic pressure sensor for real-time hemodynamic monitoring in cardiogenic shock
    Lukas Ruoff, Roxana Moayedifar, Anne-Kristin Schaefer +8
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Cardiovascular medicineCrossref
BibTeX
@article{aliev2026from,
  title = {{From Catheters to Wearables: Advanced Hemodynamic Monitoring and the Emerging Role of PPG‐Based Devices}},
  author = {Emil Aliev and Arik Eisenkraft and Dean Nachman},
  journal = {Cardiology Research and Practice},
  year = {2026},
  month = nov,
  doi = {10.1155/crp/5632972},
  url = {https://doi.org/10.1155/crp/5632972},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - From Catheters to Wearables: Advanced Hemodynamic Monitoring and the Emerging Role of PPG‐Based Devices
AU  - Emil Aliev
AU  - Arik Eisenkraft
AU  - Dean Nachman
PY  - 2026
DA  - 2026/11/09
JO  - Cardiology Research and Practice
DO  - 10.1155/crp/5632972
UR  - https://doi.org/10.1155/crp/5632972
AB  - Advanced hemodynamic monitoring, including cardiac output (CO), stroke volume (SV), and systemic vascular resistance (SVR), is important for the management of cardiogenic shock, postoperative patients, and heart failure. Traditional approaches such as pulmonary artery catheterization (PAC) provide comprehensive hemodynamic assessment but are invasive, costly, and associated with procedure‐related risks. This review summarizes established invasive and minimally invasive techniques alongside emerging noninvasive approaches, including pulse contour analysis, bioimpedance, pulse wave transit time, and photoplethysmography (PPG)‐based systems. Particular emphasis is placed on PPG‐based technologies, which combine pulse wave analysis, pulse wave transit time, and advanced signal processing to estimate blood pressure and flow‐related parameters. As a representative case study, the clinical development and evaluation of the Biobeat BB‐613WP wearable are described, including preclinical swine hemorrhagic shock models, intensive care and perioperative validation against invasive reference methods, and ambulatory blood pressure monitoring studies. Available evidence suggests that PPG‐based wearables can achieve clinically acceptable agreement with invasive reference methods in selected populations while offering the potential for continuous, noninvasive, and ambulatory monitoring. However, the available evidence is limited by small sample sizes, single‐center studies, controlled conditions, and limited independent validation. Further multicenter, outcome‐oriented studies are required to establish the clinical role of PPG‐based devices across diverse patient populations and stages of care.
SN  - 2090-8016
SN  - 2090-0597
ER  -