The TriArtic procedure: TRIcuspid annular reduction by TEER in the commissure-a transcatheter annuloplasty enabling EVOQUE tricuspid valve replacement: a case report.

  1. 1Department of Cardiology, Pulmonology, and Vascular Medicine, University Hospital Düsseldorf, Medical Faculty of the Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany.
  2. 2Cardiovascular Research Institute Düsseldorf (CARID), Medical Faculty, Heinrich-Heine University, 40225 Düsseldorf, Germany.

Abstract

Background

Transcatheter tricuspid valve replacement (TTVR) with the EVOQUE system has expanded therapeutic options for severe tricuspid regurgitation (TR), but a prohibitively dilated tricuspid annulus may exceed the device-sizing matrix and preclude implantation. No transcatheter strategy has been described to mechanically pre-condition such an annulus.Case summary

A 71-year-old woman with heart failure with reduced ejection fraction (left ventricular ejection fraction 38%, suspected premature-ventricular-complex-induced cardiomyopathy), permanent atrial fibrillation, and class III obesity presented with torrential atrial functional TR refractory to fully optimized guideline-directed medical therapy. Screening cardiac computed tomography (CT) classified the native annulus as 'outside parameters' for the 56 mm EVOQUE (Edwards Lifesciences); the Heart Team also deemed standalone tricuspid edge-to-edge repair (T-TEER) inadequate owing to the massively dilated annulus. We performed the TriArtic procedure-a single TriClip XTW (Abbott) deployed in the septo-anterior position as a transcatheter annuloplasty step. Repeat CT after 27 days demonstrated an ∼11% reduction in tricuspid annular area and conversion of projected-derived-diameter oversizing from -2.9% to +3.3% (within parameters). Transfemoral EVOQUE 56 mm was implanted 48 days after the TriClip; postprocedural imaging confirmed no residual regurgitation and a mean transtricuspid gradient of 1 mm Hg, with rapid recovery of cardiorenal function.Discussion

Transcatheter tricuspid annuloplasty by a strategically placed commissural TEER device may convert a prohibitively dilated annulus into one within EVOQUE-implantable parameters. In carefully selected patients ineligible for either standalone strategy, sequential transcatheter annuloplasty followed by valve replacement-the TriArtic procedure-may offer a feasible pathway, conceptually analogous to the mitral ARCTIC technique. This single case demonstrates feasibility only and does not establish general applicability.

Related

  1. Coexisting Moderate-to-Severe Tricuspid Regurgitation and Renal Dysfunction Identify a High-Risk Group After Transcatheter Aortic Valve Replacement
    Philipp Lauten, Birgit Markus, Georgios Chatzis +4
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Electrosurgical Clip Laceration to Facilitate Transcatheter Tricuspid Valve Replacement After Suboptimal Edge-To-Edge Repair
    Fabio Solis-Jiménez, Daniel Arnaldo Pinto-Torres, Pilar Jiménez-Quevedo +3
    Structural HeartPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
  3. Transcatheter aortic valve replacement in bicuspid versus tricuspid aortic valves among patients with mixed aortic valve disease
    Boren Tan, Qifeng Zhu, Qiong Liu +8
    BMC Cardiovascular DisordersPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMC
  4. Percutaneous closure of ruptured sinus of Valsalva and tricuspid paravalvular leak following surgical tricuspid valve replacement.
    Ruitao Li, Wenxia Zhou, Yuan Feng
    European heart journal. Case reportsPeer-reviewedCC BY-NCFull textCardiovascular medicineEurope PMCPMC
  5. Impact of Tricuspid Regurgitation on Outcomes After Transcatheter Edge-to-Edge Repair for Primary Mitral Regurgitation: The PRIME-MR Registry
    Andrea Scotti, Sebastian Ludwig, Daniel Feldman +47
    Circulation: Cardiovascular InterventionsPeer-reviewedLicence not statedSystems & synthetic biologyCardiovascular medicineHAL
BibTeX
@article{phinicarides2026triartic,
  title = {{The TriArtic procedure: TRIcuspid annular reduction by TEER in the commissure-a transcatheter annuloplasty enabling EVOQUE tricuspid valve replacement: a case report.}},
  author = {Raphael Phinicarides and Fabian Voß and Tobias Zeus and Amin Polzin},
  journal = {European heart journal. Case reports},
  year = {2026},
  month = oct,
  doi = {10.1093/ehjcr/ytag729},
  url = {https://europepmc.org/article/MED/42898779},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - The TriArtic procedure: TRIcuspid annular reduction by TEER in the commissure-a transcatheter annuloplasty enabling EVOQUE tricuspid valve replacement: a case report.
AU  - Raphael Phinicarides
AU  - Fabian Voß
AU  - Tobias Zeus
AU  - Amin Polzin
PY  - 2026
DA  - 2026/10/06
JO  - European heart journal. Case reports
DO  - 10.1093/ehjcr/ytag729
UR  - https://europepmc.org/article/MED/42898779
AB  - Background  Transcatheter tricuspid valve replacement (TTVR) with the EVOQUE system has expanded therapeutic options for severe tricuspid regurgitation (TR), but a prohibitively dilated tricuspid annulus may exceed the device-sizing matrix and preclude implantation. No transcatheter strategy has been described to mechanically pre-condition such an annulus.Case summary  A 71-year-old woman with heart failure with reduced ejection fraction (left ventricular ejection fraction 38%, suspected premature-ventricular-complex-induced cardiomyopathy), permanent atrial fibrillation, and class III obesity presented with torrential atrial functional TR refractory to fully optimized guideline-directed medical therapy. Screening cardiac computed tomography (CT) classified the native annulus as 'outside parameters' for the 56 mm EVOQUE (Edwards Lifesciences); the Heart Team also deemed standalone tricuspid edge-to-edge repair (T-TEER) inadequate owing to the massively dilated annulus. We performed the TriArtic procedure-a single TriClip XTW (Abbott) deployed in the septo-anterior position as a transcatheter annuloplasty step. Repeat CT after 27 days demonstrated an ∼11% reduction in tricuspid annular area and conversion of projected-derived-diameter oversizing from -2.9% to +3.3% (within parameters). Transfemoral EVOQUE 56 mm was implanted 48 days after the TriClip; postprocedural imaging confirmed no residual regurgitation and a mean transtricuspid gradient of 1 mm Hg, with rapid recovery of cardiorenal function.Discussion  Transcatheter tricuspid annuloplasty by a strategically placed commissural TEER device may convert a prohibitively dilated annulus into one within EVOQUE-implantable parameters. In carefully selected patients ineligible for either standalone strategy, sequential transcatheter annuloplasty followed by valve replacement-the TriArtic procedure-may offer a feasible pathway, conceptually analogous to the mitral ARCTIC technique. This single case demonstrates feasibility only and does not establish general applicability.
SN  - 2514-2119
ER  -