Analytical Validation of a Multielement ICP-MS Method for Human Serum and Its Application to Trace Element Biomonitoring in Hemodialysis Patients.

  1. 1Clinical Analysis Service, Hospital Virgen de los Lirios, Polígono de Caramanchel s/n, 03804 Alcoi, Spain.
  2. 2Analytical Chemistry Department, Nutrition and Food Sciences, University of Alicante, Carretera San Vicente del Raspeig s/n, 03690 San Vicente del Raspeig, Spain.

Abstract

Reliable determination of trace elements in human serum is essential for clinical assessment, toxicological investigations and human biomonitoring. This study describes the development and analytical validation of a multielement inductively coupled plasma mass spectrometry (ICP-MS) method for the simultaneous determination of essential and potentially toxic trace elements in human serum (Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Cd, Ba, Bi) using a simple direct-dilution procedure with 1% (v/v) nitric acid. Method validation included assessment of linearity, limits of detection and quantification, carry-over, precision, trueness, measurement uncertainty and analyte stability. Calibration curves showed excellent linearity, with coefficients of determination (R²) ranging from 0.9993 to 1.0000 across analyte-specific calibration ranges of 0-10, 0-50, and 0-500 µg L⁻¹. Repeatability ranged from 0.69% (Cu) to 14.5% (Ba), while intermediate precision ranged from 1.32% (Zn) to 81.1% (Cd and Bi at low concentrations). Recoveries obtained using certified serum reference materials ranged from 55% (V) to 206% (Bi) across the evaluated conditions. Meanwhile, limits of detection ranged from 0.01 (V) to 0.16 (Cu) µg L⁻¹. Measurement uncertainty was estimated following the EURACHEM/CITAC and GUM recommendations, identifying repeatability as the principal contributor to the overall uncertainty budget. The method was successfully applied to serum samples from healthy individuals and patients undergoing chronic hemodialysis. The proposed methodology combines simple sample preparation with comprehensive metrological characterisation, providing practical approach multielement serum analysis and its application to trace-element biomonitoring investigations.

Related

  1. Analytical validation in catalytic CO2 conversion: Product identification, carbon accounting, and evidence for process performance
    Eugene Oga
    ChemRxivPreprintCC BYFull textCatalysisChemRxiv
  2. Defining the Oxysterolome: Analytical Coverage, Metabolic Connectivity, and Biological Validation
    Silia Ayadi, Julio Buñay, Chloé Gressein +3
    Journal of Lipid ResearchPeer-reviewedCC BY 4.0Full textGeneral biochemistryCell biologyHALCrossref
  3. An imidazole-based Schiff-base chemosensor for selective, sensitive and reversible optical detection of Ni2+ ions in aqueous media: analytical and biological application
    Devanand Sahu, Abhilash Pandey, Dwaipayan Patra +5
    RSC advancesPeer-reviewedCC BY-NCFull textPhysical chemistryEurope PMCPMC
  4. Development and validation of the analytical method for determination of residual solvents (2-propanol and n-hexane) in the drug substance Inosine Pranobex.
    Khrystyna Chemna, Liliya Logoyda, Vitalii Rudiuk
    BMC chemistryPeer-reviewedCC BY-NC-NDFull textAnalytical chemistryEurope PMC
  5. A selective review of LC–MS/MS-based pesticide residue analysis (2020–2025): advances in QuEChERS methods, multi-matrix applications, and analytical validation
    S. Kathirvel, Naba Fathima, Sana Fathima +2
    Sustainable Chemistry for Climate ActionPeer-reviewedCC BYFull textGeneral chemistryEnvironmental science & pollutionDOAJ
BibTeX
@article{sanz2026analytical,
  title = {{Analytical Validation of a Multielement ICP-MS Method for Human Serum and Its Application to Trace Element Biomonitoring in Hemodialysis Patients.}},
  author = {Sara Valderrama Sanz and Raquel Sánchez Romero and Ricardo Molina Gasset and José Luis Todolí Torró},
  journal = {Toxics},
  year = {2026},
  month = oct,
  doi = {10.3390/toxics14100884},
  url = {https://europepmc.org/article/MED/42931671},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Analytical Validation of a Multielement ICP-MS Method for Human Serum and Its Application to Trace Element Biomonitoring in Hemodialysis Patients.
AU  - Sara Valderrama Sanz
AU  - Raquel Sánchez Romero
AU  - Ricardo Molina Gasset
AU  - José Luis Todolí Torró
PY  - 2026
DA  - 2026/10/01
JO  - Toxics
DO  - 10.3390/toxics14100884
UR  - https://europepmc.org/article/MED/42931671
AB  - Reliable determination of trace elements in human serum is essential for clinical assessment, toxicological investigations and human biomonitoring. This study describes the development and analytical validation of a multielement inductively coupled plasma mass spectrometry (ICP-MS) method for the simultaneous determination of essential and potentially toxic trace elements in human serum (Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Cd, Ba, Bi) using a simple direct-dilution procedure with 1% (v/v) nitric acid. Method validation included assessment of linearity, limits of detection and quantification, carry-over, precision, trueness, measurement uncertainty and analyte stability. Calibration curves showed excellent linearity, with coefficients of determination (R²) ranging from 0.9993 to 1.0000 across analyte-specific calibration ranges of 0-10, 0-50, and 0-500 µg L⁻¹. Repeatability ranged from 0.69% (Cu) to 14.5% (Ba), while intermediate precision ranged from 1.32% (Zn) to 81.1% (Cd and Bi at low concentrations). Recoveries obtained using certified serum reference materials ranged from 55% (V) to 206% (Bi) across the evaluated conditions. Meanwhile, limits of detection ranged from 0.01 (V) to 0.16 (Cu) µg L⁻¹. Measurement uncertainty was estimated following the EURACHEM/CITAC and GUM recommendations, identifying repeatability as the principal contributor to the overall uncertainty budget. The method was successfully applied to serum samples from healthy individuals and patients undergoing chronic hemodialysis. The proposed methodology combines simple sample preparation with comprehensive metrological characterisation, providing practical approach multielement serum analysis and its application to trace-element biomonitoring investigations.
SN  - 2305-6304
ER  -