Snare-Free Endoscopic Tricuspid Valve Repair Using a Percutaneous Venous Self-Expanding Cannula: A Descriptive Cohort Study
4 affiliations
- 1Doctoral School, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania
- 2Department of Cardiac Surgery, Klinikum Passau, 94032 Passau, Germany
- 3Department of Cardiovascular Surgery, Emergency Institute for Cardiovascular Diseases and Transplantation Targu Mures, 540136 Targu Mures, Romania
- 4Department of Anatomy and Embryology, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania
Abstract
Background: Minimally invasive and endoscopic techniques have expanded the surgical options for tricuspid valve repair. Conventional approaches often require manual snaring of the venae cavae, which can increase procedural complexity, especially in advanced heart failure settings. This study describes a snare-free totally endoscopic approach to tricuspid valve repair utilizing percutaneous venous self-expanding cannulation. Methods: Between 2020 and 2025, 32 patients with severe tricuspid regurgitation (TR) underwent totally endoscopic tricuspid valve repair using a standardized snare-free technique. Venous drainage was achieved via predominantly percutaneous femoral cannulation with a self-expanding venous cannula, providing central venous decompression without external tourniquets or loops. All clinical, intraoperative, and early postoperative parameters were collected and analyzed using descriptive statistical methodology. Results: Snare-free cannulation was performed in all 32 patients (100.0%, 95% CI: 89.1–100.0%). Pure snare-free endoscopic repair was completed in 31 patients (96.9%, 95% CI: 83.8–99.9%), with one patient (3.1%) requiring conversion to full median sternotomy and manual caval snaring. The mean cardiopulmonary bypass (CPB) time was 145.9 ± 35.8 min, and the mean aortic cross-clamp duration was 92.4 ± 24.5 min. All-cause 30-day mortality was 3.1% (n = 1/32), and no cases of clinically documented hemolysis were observed (0.0%, 95% CI: 0.0–10.9%). The mean intensive care unit stay was 6.0 ± 4.9 days (n = 31), and the mean postoperative hospital length of stay was 15.3 ± 9.6 days (n = 30). Quantitative predischarge residual TR grades and transvalvular gradients were not systematically recorded; therefore, endoscopic completion in this cohort establishes cannulation feasibility rather than definitive valve-repair efficacy. Conclusion: Snare-free totally endoscopic tricuspid valve repair using percutaneous self-expanding venous cannulation appeared technically feasible and was associated with acceptable early clinical outcomes in this selected single-center cohort.
Related
- Percutaneous closure of ruptured sinus of Valsalva and tricuspid paravalvular leak following surgical tricuspid valve replacement.
- Percutaneous Removal of a Tricuspid Valve Vegetation Using the AngioVac System in a Young Woman Who Injects Drugs
- A Novel Technique Using Flash 2.0 Catheter for Percutaneous Aspiration of Native Tricuspid Valve Endocarditis Caused by a Hemodialysis Venous Catheter
- Antiplatelet Therapy Strategies in Patients with High Bleeding Risk Treated with Complex Percutaneous Coronary Intervention: A Descriptive Study
- Endoscopic suturing for closure of a chronic gastrocutaneous fistula following percutaneous endoscopic gastrostomy after failed conventional endoscopic techniques
BibTeX
@article{balan2026snarefree,
title = {{Snare-Free Endoscopic Tricuspid Valve Repair Using a Percutaneous Venous Self-Expanding Cannula: A Descriptive Cohort Study}},
author = {Robert Balan and Parwis Massoudy and Marius Mihai Harpa and Klara Brînzaniuc and Jonah Schwarz},
journal = {Journal of Clinical Medicine},
year = {2026},
month = nov,
doi = {10.3390/jcm15228899},
url = {https://www.mdpi.com/2077-0383/15/22/8899},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Snare-Free Endoscopic Tricuspid Valve Repair Using a Percutaneous Venous Self-Expanding Cannula: A Descriptive Cohort Study
AU - Robert Balan
AU - Parwis Massoudy
AU - Marius Mihai Harpa
AU - Klara Brînzaniuc
AU - Jonah Schwarz
PY - 2026
DA - 2026/11/01
JO - Journal of Clinical Medicine
DO - 10.3390/jcm15228899
UR - https://www.mdpi.com/2077-0383/15/22/8899
AB - Background: Minimally invasive and endoscopic techniques have expanded the surgical options for tricuspid valve repair. Conventional approaches often require manual snaring of the venae cavae, which can increase procedural complexity, especially in advanced heart failure settings. This study describes a snare-free totally endoscopic approach to tricuspid valve repair utilizing percutaneous venous self-expanding cannulation. Methods: Between 2020 and 2025, 32 patients with severe tricuspid regurgitation (TR) underwent totally endoscopic tricuspid valve repair using a standardized snare-free technique. Venous drainage was achieved via predominantly percutaneous femoral cannulation with a self-expanding venous cannula, providing central venous decompression without external tourniquets or loops. All clinical, intraoperative, and early postoperative parameters were collected and analyzed using descriptive statistical methodology. Results: Snare-free cannulation was performed in all 32 patients (100.0%, 95% CI: 89.1–100.0%). Pure snare-free endoscopic repair was completed in 31 patients (96.9%, 95% CI: 83.8–99.9%), with one patient (3.1%) requiring conversion to full median sternotomy and manual caval snaring. The mean cardiopulmonary bypass (CPB) time was 145.9 ± 35.8 min, and the mean aortic cross-clamp duration was 92.4 ± 24.5 min. All-cause 30-day mortality was 3.1% (n = 1/32), and no cases of clinically documented hemolysis were observed (0.0%, 95% CI: 0.0–10.9%). The mean intensive care unit stay was 6.0 ± 4.9 days (n = 31), and the mean postoperative hospital length of stay was 15.3 ± 9.6 days (n = 30). Quantitative predischarge residual TR grades and transvalvular gradients were not systematically recorded; therefore, endoscopic completion in this cohort establishes cannulation feasibility rather than definitive valve-repair efficacy. Conclusion: Snare-free totally endoscopic tricuspid valve repair using percutaneous self-expanding venous cannulation appeared technically feasible and was associated with acceptable early clinical outcomes in this selected single-center cohort.
SN - 2077-0383
ER -