Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 37 min ago
Peer-reviewedCC BY 3.0Pakistan Journal of Medical Sciences

Comparative performance of Rotterdam and Helsinki CT scores for early prognostication in traumatic brain injury

4 affiliations
  1. 1Naeem Ul Haq, FCPS, Department of Neurosurgery, Mardan Medical Complex, Mardan 23200, Khyber Pakhtunkhwa, Pakistan
  2. 2Waseem Sajjad, MRCS, Department of Neurosurgery, Mardan Medical Complex, Mardan 23200, Khyber Pakhtunkhwa, Pakistan
  3. 3Bahrul Amin Khan, FCPS, Department of Neurosurgery, Mardan Medical Complex, Mardan 23200, Khyber Pakhtunkhwa, Pakistan
  4. 4Shehzad Sadbar, MBBS, Department of Neurosurgery, Mardan Medical Complex, Mardan 23200, Khyber Pakhtunkhwa, Pakistan

Abstract

Objective:: To compare the prognostic performance of the Rotterdam and Helsinki computed tomography (CT) scoring systems for predicting early outcome in traumatic brain injury (TBI).

Methodology:: This prospective observational study included consecutive patients with TBI undergoing admission non-contrast head CT at Mardan Medical Complex from February 2025 to July 2025. CT scans were scored using the Rotterdam and Helsinki systems. Outcome was assessed using the Glasgow Outcome Scale (GOS) at hospital discharge. Statistical analysis included univariable and GCS-adjusted binary logistic regression and receiver operating characteristic (ROC) analysis.

Results:: A total of 312 patients were included; 27 (8.7%) had a poor discharge outcome (GOS 1–3). Poor outcome was associated with higher Rotterdam and Helsinki CT scores and lower admission GCS (p<0.001). On univariable analysis, Rotterdam (OR 4.56) and Helsinki (OR 1.65) scores were associated with poor outcome. After adjustment for admission GCS, Helsinki remained significantly associated with poor outcome (adjusted OR 1.21, 95% CI 1.02–1.44, p=0.032), whereas Rotterdam did not (adjusted OR 1.72, 95% CI 0.88–3.34, p=0.112). Rotterdam showed AUC 0.915 (95% CI 0.868–0.963) and Helsinki AUC 0.876 (95% CI 0.781–0.970).

Conclusion:: Both scores demonstrated useful discrimination for early discharge outcome. Helsinki retained a modest independent association with poor outcome after GCS adjustment, whereas Rotterdam showed higher unadjusted discrimination. Larger cohorts with longer follow-up are needed for validation.

Related

  1. Predictive Value of the Helsinki CT Score in Traumatic Brain Injury: A Systematic Review and Meta-Analysis.
    Yun-Lin Zhang, Yi-Ming Li, Bo-Yu Zhang
    Journal of neuroimaging : official journal of the American Society of NeuroimagingPeer-reviewedCC BYFull textNeurologyEurope PMC
  2. Validation and Performance of Five Upper Gastrointestinal Bleeding Prognostication Scores in a Single-Centre United Kingdom Cohort of over 1000 Patients
    Mohamed Jalloh, Balamrit Singh Sokhal, Maryam Nusrat Javed +5
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Comparison of Prognostic Performance, Sensitivity, Specificity, and Long-Term Outcome Prediction in Biomarkers for Pediatric Traumatic Brain Injuries: A Review
    Joseph L. Fracasso, Larissa Russo, Nasim Ahmed
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Prevalence of Unrecognized and Recognized Myocardial Infarction in the Rotterdam Study
    Julie Anne Eni van Oortmerssen, Shuyue Yang, Ali Farzaneh +3
    JAMA CardiologyPeer-reviewedLicence not statedFull textCardiovascular medicinePMC
  5. Prehospital Needle Thoracostomies in Traumatic Cardiac Arrest: Forensic Insights into Procedural Performance and Successes
    Thomas W. Engel, Aaron Amundson, Lauren Nickel +4
    Academic Forensic PathologyPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
BibTeX
@article{haq2026comparative,
  title = {{Comparative performance of Rotterdam and Helsinki CT scores for early prognostication in traumatic brain injury}},
  author = {Naeem Ul Haq and Waseem Sajjad and Bahrul Amin Khan and Shehzad Sadbar},
  journal = {Pakistan Journal of Medical Sciences},
  year = {2026},
  month = nov,
  doi = {10.12669/pjms.42.10.15563},
  url = {https://doi.org/10.12669/pjms.42.10.15563},
  note = {CC BY 3.0},
}
RIS
TY  - JOUR
TI  - Comparative performance of Rotterdam and Helsinki CT scores for early prognostication in traumatic brain injury
AU  - Naeem Ul Haq
AU  - Waseem Sajjad
AU  - Bahrul Amin Khan
AU  - Shehzad Sadbar
PY  - 2026
DA  - 2026/11/17
JO  - Pakistan Journal of Medical Sciences
DO  - 10.12669/pjms.42.10.15563
UR  - https://doi.org/10.12669/pjms.42.10.15563
AB  - Objective:: To compare the prognostic performance of the Rotterdam and Helsinki computed tomography (CT) scoring systems for predicting early outcome in traumatic brain injury (TBI).  Methodology:: This prospective observational study included consecutive patients with TBI undergoing admission non-contrast head CT at Mardan Medical Complex from February 2025 to July 2025. CT scans were scored using the Rotterdam and Helsinki systems. Outcome was assessed using the Glasgow Outcome Scale (GOS) at hospital discharge. Statistical analysis included univariable and GCS-adjusted binary logistic regression and receiver operating characteristic (ROC) analysis.  Results:: A total of 312 patients were included; 27 (8.7%) had a poor discharge outcome (GOS 1–3). Poor outcome was associated with higher Rotterdam and Helsinki CT scores and lower admission GCS (p<0.001). On univariable analysis, Rotterdam (OR 4.56) and Helsinki (OR 1.65) scores were associated with poor outcome. After adjustment for admission GCS, Helsinki remained significantly associated with poor outcome (adjusted OR 1.21, 95% CI 1.02–1.44, p=0.032), whereas Rotterdam did not (adjusted OR 1.72, 95% CI 0.88–3.34, p=0.112). Rotterdam showed AUC 0.915 (95% CI 0.868–0.963) and Helsinki AUC 0.876 (95% CI 0.781–0.970).  Conclusion:: Both scores demonstrated useful discrimination for early discharge outcome. Helsinki retained a modest independent association with poor outcome after GCS adjustment, whereas Rotterdam showed higher unadjusted discrimination. Larger cohorts with longer follow-up are needed for validation.
SN  - 1682-024X
SN  - 1681-715X
ER  -