Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BYPhysiological reports

Test-retest reliability and minimal detectable change of pulse wave velocity and flow-mediated dilation in paretic and non-paretic limbs of older adults post-stroke.

5 affiliations
  1. 1School of Rehabilitation Sciences, Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada.
  2. 2St. John's Rehab, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.
  3. 3Medicine, the Research Institute of St. Joe's, Hamilton, Ontario, Canada.
  4. 4Department of Kinesiology, Faculty of Science, McMaster University, Hamilton, Ontario, Canada.
  5. 5School of Physical & Occupational Therapy, Faculty of Medicine, McGill University, Montreal, Canada.

Abstract

Arterial stiffness and endothelial dysfunction are non-traditional risk markers after stroke, yet reliability and minimal detectable change (MDC) of pulse wave velocity (PWV) and flow-mediated dilation (FMD) have not been established. We examined test-retest reliability and MDC of carotid-femoral (cfPWV), carotid-radial (crPWV), and femoral-dorsalis pedis PWV (ffPWV), and absolute and relative brachial artery FMD in people >12 months post-stroke. Seventeen individuals (n = 4 (24%) females; 63.9 ± 8.6 years; 4.5 ± 2.8 years post-stroke) completed two bilateral assessments of PWV via applanation tonometry and FMD via duplex ultrasound within 1 week. Intraclass correlation coefficients (ICC2,1) were calculated via two-way random-effects models, and MDC derived at 68%, 90%, and 95% confidence levels. We found good-to-excellent reliability for cfPWV in paretic (ICC2,1 = 0.85; 95% CI:0.59, 0.95) and non-paretic (ICC2,1 = 0.94; 95% CI:0.82, 0.98) limbs, with MDC95% values of 2.23 and 1.68 m/s, respectively. crPWV and ffPWV exhibited poor reliability bilaterally (ICC2,1 = 0.12-0.33). Relative FMD showed moderate reliability for paretic (ICC2,1 = 0.50; 95% CI: -0.20, 0.85) and non-paretic (ICC = 0.59; 95% CI:0.04, 0.84) limbs, with MDC95% values of 6.88% and 7.65%, respectively. Reliability for absolute FMD was poor (ICC2,1 = 0.11-0.44). These findings support cfPWV as a reliable vascular assessment in individuals >12 months post-stroke, and provide stroke-specific MDC values to guide interpretability in future trials.

Related

  1. Decision Limits for Fetal Speckle-Tracking Outputs: Minimal Detectable Change and Threshold Instability in FetalHQ
    Jakub Mlodawski, Anna Zmelonek-Znamirowska, Lukasz Pawlik +2
    BiomedicinesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Phenotyping Antibody-mediated Rejection Without Detectable Donor-specific Antibodies 8 d After Heart Transplantation: A Case Study
    Sarah Flint, Aiwen Zhang, Gabriel Kim +4
    Transplantation directPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Reliability of a Standardized Isokinetic Knee Strength Protocol Across a Slow–Fast Velocity Spectrum in Physically Active Adults with the Biodex System 4 Pro
    International journal of sports physical therapyPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  4. Minimal Detectable Change in Gait Biomechanics Post-Stroke: Disentangling the Effects of Walking Speed and Stroke-Related Variability
    A. A. Ramirez, A. Kuch, R. T. Johnson +1
    medRxivPreprintCC BYFull text1 citedGeneral medicinemedRxiv
  5. Independent linear association between flow-mediated dilation and predicted intermediate-to-high 10-year ASCVD risk in patients with type 2 diabetes: a retrospective study
    Hou KJ, Shen SY, Zong CY +4
    Frontiers in EndocrinologyPeer-reviewedCC BY 4.0Full textCardiovascular medicineCrossrefEurope PMCPMC
BibTeX
@article{abreu2026testretest,
  title = {{Test-retest reliability and minimal detectable change of pulse wave velocity and flow-mediated dilation in paretic and non-paretic limbs of older adults post-stroke.}},
  author = {Juliano A Abreu and Natalie D'Isabella and Derek W Stouth and Maureen J MacDonald and Ada Tang and Kevin Moncion},
  journal = {Physiological reports},
  year = {2026},
  month = oct,
  doi = {10.14814/phy2.71138},
  url = {https://europepmc.org/article/MED/42897953},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Test-retest reliability and minimal detectable change of pulse wave velocity and flow-mediated dilation in paretic and non-paretic limbs of older adults post-stroke.
AU  - Juliano A Abreu
AU  - Natalie D'Isabella
AU  - Derek W Stouth
AU  - Maureen J MacDonald
AU  - Ada Tang
AU  - Kevin Moncion
PY  - 2026
DA  - 2026/10/01
JO  - Physiological reports
DO  - 10.14814/phy2.71138
UR  - https://europepmc.org/article/MED/42897953
AB  - Arterial stiffness and endothelial dysfunction are non-traditional risk markers after stroke, yet reliability and minimal detectable change (MDC) of pulse wave velocity (PWV) and flow-mediated dilation (FMD) have not been established. We examined test-retest reliability and MDC of carotid-femoral (cfPWV), carotid-radial (crPWV), and femoral-dorsalis pedis PWV (ffPWV), and absolute and relative brachial artery FMD in people >12 months post-stroke. Seventeen individuals (n = 4 (24%) females; 63.9 ± 8.6 years; 4.5 ± 2.8 years post-stroke) completed two bilateral assessments of PWV via applanation tonometry and FMD via duplex ultrasound within 1 week. Intraclass correlation coefficients (ICC2,1) were calculated via two-way random-effects models, and MDC derived at 68%, 90%, and 95% confidence levels. We found good-to-excellent reliability for cfPWV in paretic (ICC2,1 = 0.85; 95% CI:0.59, 0.95) and non-paretic (ICC2,1 = 0.94; 95% CI:0.82, 0.98) limbs, with MDC95% values of 2.23 and 1.68 m/s, respectively. crPWV and ffPWV exhibited poor reliability bilaterally (ICC2,1 = 0.12-0.33). Relative FMD showed moderate reliability for paretic (ICC2,1 = 0.50; 95% CI: -0.20, 0.85) and non-paretic (ICC = 0.59; 95% CI:0.04, 0.84) limbs, with MDC95% values of 6.88% and 7.65%, respectively. Reliability for absolute FMD was poor (ICC2,1 = 0.11-0.44). These findings support cfPWV as a reliable vascular assessment in individuals >12 months post-stroke, and provide stroke-specific MDC values to guide interpretability in future trials.
SN  - 2051-817X
ER  -