Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 50 min ago
Peer-reviewedCC BY 4.0Respiratory Physiology & Neurobiology

Fixed-point spirometry biases the evaluation of posturo-respiratory coupling: A comparison with optoelectronic plethysmography

Abstract

Posturo-respiratory coupling (PRC) reflects the interaction between breathing and postural control, and its accurate assessment is essential for understanding breathing-related balance disorders. This study investigates whether the use of a fixed-point spirometer to assess breathing profile biases PRC evaluation compared to a contactless method-optoelectronic plethysmography (OEP). Thirty healthy participants underwent two conditions in a random order: natural breathing and breathing through a spirometer. Segmental oscillations and center of pressure (CoP) displacements were recorded using contactless motion capture and force platform. Respiratory emergence (REm) and Time Lock Averaging (TLA) were used to assess the effect of breathing on the multi-segmental balance. Breathing through a spirometer significantly reduced the amplitude and velocity of segmental oscillations and CoP displacement compared to natural breathing, while breathing frequency remained unchanged. The spirometer condition induced higher incidence of neck flexion during inspiration (TLA), and altered the REm, particularly by increasing REm at the shoulder level. These findings suggest that using a fixed-point, in-contact spirometer introduces a significant bias in PRC measurements. Two mechanisms of PRC alteration are suggested: (1) due to the physical constraints associated with subject's connection with the device; (2) of cortical origin in response to mouth breathing. In conclusion, although spirometry remains a gold standard for breathing assessment, it is unsuitable for PRC evaluation due to its disruptive influence on natural postural-respiratory dynamics. OEP, by preserving natural breathing and posture, offers a more reliable alternative for studying PRC, especially in ecological or clinical contexts such as respiratory rehabilitation or musical performance.

Related

  1. Relative phase noise suppression for two-color optical sources via optoelectronic feedback and feedforward
    Yiwen Lu, Tong Yang, Qizhuang Cen +5
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  2. A programmable optoelectronic Ising machine for direct third-order optimization
    Xuelong Ma, Zhentong Li, Qi Chen +8
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  3. Dosimetric Comparison of One-, Two-, Three-, and Four-Arc Volumetric Modulated Arc Therapy Plans in Cervical Carcinoma: Evaluation of Plan Quality, Organ-at-Risk Sparing, and Treatment Efficiency.
    Priyadharshini G, Himanshi Khattar, Piyush Kumar
    CureusPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  4. Integrated optoelectronic chip technologies for quantum information processing
    Lantian Feng, Kun Wang, Linrunde Tao +12
    National Science ReviewPeer-reviewedCC BY 4.0Full text1 citedQuantum physics & quantum informationPMC
  5. Computational investigation of a perovskite LaBiO3 for photovoltaic, thermoelectric, and optoelectronic applications
    M. M. Woldemariam, N. G. Debelo, T. K. Tufa +4
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
BibTeX
@article{valentin2026fixedpoint,
  title = {{Fixed-point spirometry biases the evaluation of posturo-respiratory coupling: A comparison with optoelectronic plethysmography}},
  author = {Rémi Valentin and Benoit Fabre and Delphine Chadefaux and Nathan Ouvrai and Thomas Similowski and Baptiste Sandoz and Valérie Attali},
  journal = {Respiratory Physiology \& Neurobiology},
  year = {2026},
  month = oct,
  doi = {10.1016/j.resp.2025.104528},
  url = {https://hal.science/hal-05795776v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Fixed-point spirometry biases the evaluation of posturo-respiratory coupling: A comparison with optoelectronic plethysmography
AU  - Rémi Valentin
AU  - Benoit Fabre
AU  - Delphine Chadefaux
AU  - Nathan Ouvrai
AU  - Thomas Similowski
AU  - Baptiste Sandoz
AU  - Valérie Attali
PY  - 2026
DA  - 2026/10/12
JO  - Respiratory Physiology & Neurobiology
DO  - 10.1016/j.resp.2025.104528
UR  - https://hal.science/hal-05795776v1
AB  - Posturo-respiratory coupling (PRC) reflects the interaction between breathing and postural control, and its accurate assessment is essential for understanding breathing-related balance disorders. This study investigates whether the use of a fixed-point spirometer to assess breathing profile biases PRC evaluation compared to a contactless method-optoelectronic plethysmography (OEP). Thirty healthy participants underwent two conditions in a random order: natural breathing and breathing through a spirometer. Segmental oscillations and center of pressure (CoP) displacements were recorded using contactless motion capture and force platform. Respiratory emergence (REm) and Time Lock Averaging (TLA) were used to assess the effect of breathing on the multi-segmental balance. Breathing through a spirometer significantly reduced the amplitude and velocity of segmental oscillations and CoP displacement compared to natural breathing, while breathing frequency remained unchanged. The spirometer condition induced higher incidence of neck flexion during inspiration (TLA), and altered the REm, particularly by increasing REm at the shoulder level. These findings suggest that using a fixed-point, in-contact spirometer introduces a significant bias in PRC measurements. Two mechanisms of PRC alteration are suggested: (1) due to the physical constraints associated with subject's connection with the device; (2) of cortical origin in response to mouth breathing. In conclusion, although spirometry remains a gold standard for breathing assessment, it is unsuitable for PRC evaluation due to its disruptive influence on natural postural-respiratory dynamics. OEP, by preserving natural breathing and posture, offers a more reliable alternative for studying PRC, especially in ecological or clinical contexts such as respiratory rehabilitation or musical performance.
SN  - 1569-9048
SN  - 1878-1519
ER  -