Skip to content
DraconiticResearch
Search Sources API
194,164 studies31 sourcesUpdated 31 min ago
PreprintCC BY 4.0arXiv

From phase analysis to phase tracking: a robust approach to atomic-scale strain mapping

Abstract

Atomic-scale strain governs the electronic, ferroic and mechanical properties of materials, and atomic-resolution microscopy measures it most directly. Geometric phase analysis (GPA) is the standard tool, but it fails when a Bragg reflection moves outside its fixed Fourier aperture under large strain or rotation, or in misoriented grains. Here we introduce geometric phase tracking analysis (GPTA), whose Fourier aperture tracks the Bragg reflection at each pixel in real space. A narrow aperture can therefore reject noise without losing a displaced reflection. On 13,795 simulated and experimental atomic-resolution images under various imaging conditions, GPTA reduces GPA's failure rate from 27% to 11.5% with up to 335 times better accuracy. It also gives strain and dislocation maps across grains, resistance to dynamical-scattering extinction, and a confidence map, capabilities that GPA lacks. Tracking the aperture combines reciprocal-space dose efficiency with real-space spatial resolution and extends atomic-scale strain metrology to beam-sensitive materials and challenging imaging conditions.

Related

  1. Mapping Strain and Spatial-Modulation Phase from Local Wave Vectors in Scanning Tunneling Microscopy
    Xinze Yang, Sandra Sajan, Maria N. Gastiasoro +2
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  2. Measurement of strain by tracking of nano-droplets, application for the study of slip bands in steel Eurofer97
    A Ollivier, Döme Tanguy
    HALPreprintCC BY 4.0Full textGeneral physicsHAL
  3. Robust Spin Splitting and Strain-Controlled Optical Response in Monolayer CrC2N4 for Valleytronic and Optoelectronic Applications
    Md. Samrat, Vivek Chowdhury, Sake Wang +1
    arXivPreprintCC BY-NC-ND 4.0Full textCondensed matterQuantum physics & quantum informationarXiv
  4. Bend Contour Electron Tomography (BCET): Quantitative strain and topography mapping
    Henry G. Bell, Chenhang Xu, Arthur McCray +5
    arXivPreprintarXiv licenceFull textComputational physicsCondensed matterarXiv
  5. Quantitative near-atomic-resolution oxidation-state mapping in complex oxide heterostructures by electron energy-loss spectroscopy
    Ioannis Iatrakis, Zitao Zhang, Ricardo Egoavil +3
    arXivPreprintarXiv licenceFull textAtomic, molecular & optical physicsCondensed matterarXiv
BibTeX
@misc{han2026from,
  title = {{From phase analysis to phase tracking: a robust approach to atomic-scale strain mapping}},
  author = {Ying Han and Yuan Tian},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.30665},
  eprint = {2610.30665},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.30665},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - From phase analysis to phase tracking: a robust approach to atomic-scale strain mapping
AU  - Ying Han
AU  - Yuan Tian
PY  - 2026
DA  - 2026/10/22
PB  - arXiv
DO  - 10.48550/arxiv.2610.30665
UR  - https://arxiv.org/abs/2610.30665
AB  - Atomic-scale strain governs the electronic, ferroic and mechanical properties of materials, and atomic-resolution microscopy measures it most directly. Geometric phase analysis (GPA) is the standard tool, but it fails when a Bragg reflection moves outside its fixed Fourier aperture under large strain or rotation, or in misoriented grains. Here we introduce geometric phase tracking analysis (GPTA), whose Fourier aperture tracks the Bragg reflection at each pixel in real space. A narrow aperture can therefore reject noise without losing a displaced reflection. On 13,795 simulated and experimental atomic-resolution images under various imaging conditions, GPTA reduces GPA's failure rate from 27% to 11.5% with up to 335 times better accuracy. It also gives strain and dislocation maps across grains, resistance to dynamical-scattering extinction, and a confidence map, capabilities that GPA lacks. Tracking the aperture combines reciprocal-space dose efficiency with real-space spatial resolution and extends atomic-scale strain metrology to beam-sensitive materials and challenging imaging conditions.
ER  -