Navigation-Assisted and Robotic Total Hip, Knee, and Unicompartmental Arthroplasty: Reconciling Positioning Accuracy with Biomaterial Performance and Long-Term Implant Survival.
5 affiliations
- 1Department of Medicine, Mazandaran University of Medical Sciences, Sari 48157-33971, Iran.
- 2Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz 71348-14336, Iran.
- 3Philadelphia College of Osteopathic Medicine, 4190 City Avenue, Philadelphia, PA 19131, USA.
- 4Department of Orthopaedic Surgery, Aalborg University Hospital, 9000 Aalborg, Denmark.
- 5Anderson Orthopaedic Research Institute, Alexandria, VA 22306, USA.
Abstract
Navigation-assisted and robotic systems improve component positioning in total hip (THA), total knee (TKA), and unicompartmental knee arthroplasty (UKA), but whether this improves biomaterial performance and implant survival is unclear. This structured narrative review asks for which bearing materials and fixation interfaces positioning accuracy plausibly alters the degradation and fixation pathways that govern survival, and how strong the evidence is for each link. We propose a conceptual model linking positioning to the local mechanical environment, material-specific degradation, biological response, and survival, and grade each link's evidence by study design. Enabling technologies consistently reduce outliers. Position-dependent degradation is well documented for conventional polyethylene, ceramic-on-ceramic, and metal-on-metal bearings, mainly from simulator, retrieval, and cohort studies. Highly cross-linked polyethylene appears to attenuate the wear penalty of malposition, although rim fatigue and impingement remain position-sensitive and vitamin E stabilization has no proven additional clinical benefit. In cementless TKA, varus alignment is associated with greater early tibial migration, a validated surrogate for loosening. Clinical translation remains limited: trials and registries show no consistent reduction in all-cause revision after TKA or THA, with lower dislocation after THA and a more favorable UKA signal as exceptions. Precision may matter most for position-sensitive bearings and cementless interfaces.
Related
- Culture-Specific Outcomes of Intra-Articular Antibiotic Infusion With Implant-Retaining Debridement for Periprosthetic Joint Infection After Unicompartmental Knee Arthroplasty
- Comparison of clinical outcomes between mobile- and fixed-bearing unicompartmental knee arthroplasty for medial compartment osteoarthritis: a retrospective study
- Substantial improvement in short-term survivorship in patients receiving robotic arm-assisted medial unicompartmental knee arthroplasty : a retrospective cohort study
- Endovascular repair of iatrogenic popliteal artery injury with acute limb ischemia during unicompartmental knee arthroplasty
- Personalized Revision Arthroplasty After Failed Medial Unicompartmental Knee Arthroplasty: A Contemporary Narrative Review
BibTeX
@article{tavakoli2026navigationassisted,
title = {{Navigation-Assisted and Robotic Total Hip, Knee, and Unicompartmental Arthroplasty: Reconciling Positioning Accuracy with Biomaterial Performance and Long-Term Implant Survival.}},
author = {Yasaman Tavakoli and Fatemeh Kanaani Nejad and Kartik Varsani and Roshan Latifi and Mohammad Poursalehian and Jad Ismail and Robert A Sershon},
journal = {Bioengineering (Basel, Switzerland)},
year = {2026},
month = oct,
doi = {10.3390/bioengineering13101182},
url = {https://europepmc.org/article/MED/42939037},
note = {CC BY},
}
RIS
TY - JOUR
TI - Navigation-Assisted and Robotic Total Hip, Knee, and Unicompartmental Arthroplasty: Reconciling Positioning Accuracy with Biomaterial Performance and Long-Term Implant Survival.
AU - Yasaman Tavakoli
AU - Fatemeh Kanaani Nejad
AU - Kartik Varsani
AU - Roshan Latifi
AU - Mohammad Poursalehian
AU - Jad Ismail
AU - Robert A Sershon
PY - 2026
DA - 2026/10/10
JO - Bioengineering (Basel, Switzerland)
DO - 10.3390/bioengineering13101182
UR - https://europepmc.org/article/MED/42939037
AB - Navigation-assisted and robotic systems improve component positioning in total hip (THA), total knee (TKA), and unicompartmental knee arthroplasty (UKA), but whether this improves biomaterial performance and implant survival is unclear. This structured narrative review asks for which bearing materials and fixation interfaces positioning accuracy plausibly alters the degradation and fixation pathways that govern survival, and how strong the evidence is for each link. We propose a conceptual model linking positioning to the local mechanical environment, material-specific degradation, biological response, and survival, and grade each link's evidence by study design. Enabling technologies consistently reduce outliers. Position-dependent degradation is well documented for conventional polyethylene, ceramic-on-ceramic, and metal-on-metal bearings, mainly from simulator, retrieval, and cohort studies. Highly cross-linked polyethylene appears to attenuate the wear penalty of malposition, although rim fatigue and impingement remain position-sensitive and vitamin E stabilization has no proven additional clinical benefit. In cementless TKA, varus alignment is associated with greater early tibial migration, a validated surrogate for loosening. Clinical translation remains limited: trials and registries show no consistent reduction in all-cause revision after TKA or THA, with lower dislocation after THA and a more favorable UKA signal as exceptions. Precision may matter most for position-sensitive bearings and cementless interfaces.
SN - 2306-5354
ER -