Deuterium Metabolic Imaging-Based Methods for Assessment of the Hepatocellular Lipid Content.
4 affiliations
- 1Division of Endocrinology and Metabolism, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
- 2High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
- 3Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK), Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
- 4Comprehensive Center for Artificial Intelligence in Medicine, Medical University of Vienna, Vienna, Austria.
Abstract
As the liver is one of the key organs in the regulation of the lipid metabolism, it is of high interest to get detailed insights into physiological pathways and a better understanding of pathologies. This can be achieved by quantifying liver lipids using proton magnetic resonance spectroscopy (¹H-MRS), for example. Deuterium metabolic imaging (DMI) offers a new way to derive the hepatic content of lipids (HCL), enabling dynamic studies with the administration of deuterated substances. The present study is a first step towards this goal, demonstrating successful DMI-based HCL assessment without deuterium enrichment. Therefore, two different spatial encoding schemes for magnetic resonance spectroscopic imaging (MRSI) were applied: conventional phase encoding (PHE) and concentric ring trajectories (CRT). The results are in good agreement with a well-established ¹H-MRS technique, with Pearson correlation coefficients of 0.82 and 0.84 for the methylene only content and linear regression coefficients of 0.85 and 0.75 for the thereof derived HCL for both PHE and CRT, respectively. The feasibility of assessing the naturally abundant deuterium liver lipids with DMI lays the foundation for dynamic studies using ²H-enriched tracers in order to investigate the hepatic lipid metabolism in more detail as an accompanying method to ¹H-based techniques.
Related
- EP03.05 Characterising Metabolic Reprogramming in Glioblastoma Using 7T Deuterium Metabolic Imaging
- Multimodal biomarkers for early detection and immunotherapy assessment in hepatocellular carcinoma: integrating liquid biopsy, AI-based imaging and tumor immune profiling.
- Current imaging methods and molecular biomarkers for hepatocellular carcinoma diagnosis: a narrative review.
- Magnetic resonance imaging-based radiomics for predicting P53-mutated hepatocellular carcinoma: intratumoral and peritumoral analysis
- Metabolic reprogramming and drug resistance in hepatocellular carcinoma: The emerging role of SREBP2-driven cholesterol metabolism
BibTeX
@article{pfleger2026deuterium,
title = {{Deuterium Metabolic Imaging-Based Methods for Assessment of the Hepatocellular Lipid Content.}},
author = {Lorenz Pfleger and Viola Bader and Fabian Niess and Anna Tosin and Clemens Baumgartner and Peter Wolf and Anna Duguid and Bernhard Strasser and Thomas Scherer and Wolfgang Bogner and Martin Krššák},
journal = {NMR in biomedicine},
year = {2026},
month = nov,
doi = {10.1002/nbm.70442},
url = {https://europepmc.org/article/MED/43064407},
note = {CC BY},
}
RIS
TY - JOUR
TI - Deuterium Metabolic Imaging-Based Methods for Assessment of the Hepatocellular Lipid Content.
AU - Lorenz Pfleger
AU - Viola Bader
AU - Fabian Niess
AU - Anna Tosin
AU - Clemens Baumgartner
AU - Peter Wolf
AU - Anna Duguid
AU - Bernhard Strasser
AU - Thomas Scherer
AU - Wolfgang Bogner
AU - Martin Krššák
PY - 2026
DA - 2026/11/20
JO - NMR in biomedicine
DO - 10.1002/nbm.70442
UR - https://europepmc.org/article/MED/43064407
AB - As the liver is one of the key organs in the regulation of the lipid metabolism, it is of high interest to get detailed insights into physiological pathways and a better understanding of pathologies. This can be achieved by quantifying liver lipids using proton magnetic resonance spectroscopy (¹H-MRS), for example. Deuterium metabolic imaging (DMI) offers a new way to derive the hepatic content of lipids (HCL), enabling dynamic studies with the administration of deuterated substances. The present study is a first step towards this goal, demonstrating successful DMI-based HCL assessment without deuterium enrichment. Therefore, two different spatial encoding schemes for magnetic resonance spectroscopic imaging (MRSI) were applied: conventional phase encoding (PHE) and concentric ring trajectories (CRT). The results are in good agreement with a well-established ¹H-MRS technique, with Pearson correlation coefficients of 0.82 and 0.84 for the methylene only content and linear regression coefficients of 0.85 and 0.75 for the thereof derived HCL for both PHE and CRT, respectively. The feasibility of assessing the naturally abundant deuterium liver lipids with DMI lays the foundation for dynamic studies using ²H-enriched tracers in order to investigate the hepatic lipid metabolism in more detail as an accompanying method to ¹H-based techniques.
SN - 0952-3480
SN - 1099-1492
ER -