Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 39 min ago
Peer-reviewedCC BYEuropean heart journal. Valvular and structural heart disease

Anaesthetic strategy and functional outcomes during contemporary transcatheter mitral edge-to-edge repair: a matched comparison of dexmedetomidine-based conscious sedation versus general anaesthesia.

8 affiliations
  1. 1Deutsches Herzzentrum der Charité, Department of Cardiology, Angiology and Intensive Care Medicine, Campus Benjamin Franklin, Hindenburgdamm 30, Berlin 12203, Germany.
  2. 2Department of Cardiology, Angiology and Intensive Care Medicine, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, Berlin 12203, Germany.
  3. 3DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Potsdamer Straße 58, Berlin 10785, Germany.
  4. 4Department of Anesthesiology and Intensive Care Medicine, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Hindenburgdamm 30, Berlin 12203, Germany.
  5. 5Berlin Institute of Health, Charité - Universitätsmedizin Berlin, Charitéplatz 1, Berlin 10117, Germany.
  6. 6Friede Springer - Cardiovascular Prevention Center, Charité Universitaetsmedizin Berlin, Hindenburgdamm 30, Berlin 12203, Germany.
  7. 7Helmholtz-Zentrum Hereon, Institute of Active Polymers and Berlin-Brandenburg Center for Regenerative Therapies, Kantstraße 55, Teltow 14513, Brandenburg, Germany.
  8. 8Department of Anaesthesiology, Intensive Care-, Emergency- and Pain-Medicine, Evangelical Hospital Herne, Westring 24, Herne 44623, Germany.

Abstract

Background and aims

Transcatheter mitral edge-to-edge repair (M-TEER) is an established therapy for severe mitral regurgitation (MR) in patients at increased surgical risk. While procedures are commonly performed under general anaesthesia (GA), dexmedetomidine-based conscious sedation (DCS) may preserve physiological haemodynamics and improve procedural efficiency. Comparative data remain limited. To compare procedural effectiveness, efficiency and safety of M-TEER performed under GA versus DCS.Methods

In this retrospective observational study, patients undergoing M-TEER under anaesthesiologist-guided DCS or GA were analysed using propensity score matching to adjust for baseline differences. The primary endpoint was device effectiveness, defined as successful implantation with MR reduction to ≤2+ post-procedure and sustained at discharge. Procedural duration was analysed as a secondary workflow endpoint. The main safety endpoint was a composite of all-cause death, stroke, cardiac structural complications, cardiogenic shock, acute kidney injury requiring renal replacement therapy, or moderate/severe bleeding according to Mitral Valve Academic Research Consortium criteria.Results

Ninety-seven patients were included (DCS 37; GA 60). Device implantation success was achieved in 98.9% of procedures. Immediate device effectiveness was high and comparable between strategies (100 vs 98.3%; P = 1.0). Procedural duration was shorter with DCS [84 (interquartile range 70.5-111.5) vs 102.5 (78-144) min; P = .019]. In matched analysis (36 pairs), fluoroscopy time, radiation dose, and residual MR at discharge (MR ≤1: 86.1 vs 83.3%; P = .743) were similar. The composite safety endpoint did not differ significantly (P = .436), and no surgical conversions occurred.Conclusions

Dexmedetomidine-based conscious sedation provided procedural effectiveness and safety comparable to GA while improving procedural efficiency. These findings support an individualized anaesthetic strategy and warrant prospective evaluation in contemporary M-TEER practice.

Related

  1. Dexmedetomidine Versus Dexamethasone as Adjuvants to Bupivacaine for Wound Infiltration After Caesarean Section Under Spinal Anaesthesia
    Shabnam Goyal, Pooja Gunwal, Deepak K Saini +2
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Impact of Loco-regional Anaesthetic Techniques Versus General Anaesthesia in Women Aged ≥ 65 Undergoing Primary Breast Cancer Surgery: A Systematic Review of the Literature
    Catriona Staunton, Rachel Lee, Troy S. Wildes +3
    Advances in TherapyPeer-reviewedCC BY-NC 4.0Full textSurgery & anaesthesiaPMC
  3. Airway management and anaesthetic interventions for children with cleft lip and/or palate undergoing general anaesthesia: Protocol for a systematic review and meta-analysis
    Sharmin Akter Sumi, Kazi Mahzabin Arin, Shahriar Mohd Shams +5
    PLOS OnePeer-reviewedCC BY 4.0Full textDevelopmental biologyStatisticsPLOSPMC
  4. Combined Pectoral Nerve Block and Intravenous Dexmedetomidine in Contemporary Multimodal Breast Cancer Analgesia: A Real-World Cohort Study
    Cornelia Weidinger, Aicha Idrissi, Khaled Abuamra +4
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Dexmedetomidine versus Subanaesthetic Ketamine for Opioid-sparing Anaesthesia During Lumbar Spine Surgery Under a Standardised Surgical Pleth Index-guided Analgesic Protocol: A Randomised Controlled Trial.
    Gowthaman Arivuselvan, Srinivasan Swaminathan, Rajasekar Ramadurai +1
    Turkish journal of anaesthesiology and reanimationPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
BibTeX
@article{rroku2026anaesthetic,
  title = {{Anaesthetic strategy and functional outcomes during contemporary transcatheter mitral edge-to-edge repair: a matched comparison of dexmedetomidine-based conscious sedation versus general anaesthesia.}},
  author = {Andi Rroku and Theodor Kempe and Tharusan Thevathasan and Mario Kasner and Anna Sannino and Carsten Skurk and Sascha Treskatsch and Ulf Landmesser and Markus Reinthaler and Christian Berger},
  journal = {European heart journal. Valvular and structural heart disease},
  year = {2026},
  month = jul,
  doi = {10.1093/ehjvshd/xwag057},
  url = {https://europepmc.org/article/MED/43053853},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Anaesthetic strategy and functional outcomes during contemporary transcatheter mitral edge-to-edge repair: a matched comparison of dexmedetomidine-based conscious sedation versus general anaesthesia.
AU  - Andi Rroku
AU  - Theodor Kempe
AU  - Tharusan Thevathasan
AU  - Mario Kasner
AU  - Anna Sannino
AU  - Carsten Skurk
AU  - Sascha Treskatsch
AU  - Ulf Landmesser
AU  - Markus Reinthaler
AU  - Christian Berger
PY  - 2026
DA  - 2026/07/14
JO  - European heart journal. Valvular and structural heart disease
DO  - 10.1093/ehjvshd/xwag057
UR  - https://europepmc.org/article/MED/43053853
AB  - Background and aims  Transcatheter mitral edge-to-edge repair (M-TEER) is an established therapy for severe mitral regurgitation (MR) in patients at increased surgical risk. While procedures are commonly performed under general anaesthesia (GA), dexmedetomidine-based conscious sedation (DCS) may preserve physiological haemodynamics and improve procedural efficiency. Comparative data remain limited. To compare procedural effectiveness, efficiency and safety of M-TEER performed under GA versus DCS.Methods  In this retrospective observational study, patients undergoing M-TEER under anaesthesiologist-guided DCS or GA were analysed using propensity score matching to adjust for baseline differences. The primary endpoint was device effectiveness, defined as successful implantation with MR reduction to ≤2+ post-procedure and sustained at discharge. Procedural duration was analysed as a secondary workflow endpoint. The main safety endpoint was a composite of all-cause death, stroke, cardiac structural complications, cardiogenic shock, acute kidney injury requiring renal replacement therapy, or moderate/severe bleeding according to Mitral Valve Academic Research Consortium criteria.Results  Ninety-seven patients were included (DCS 37; GA 60). Device implantation success was achieved in 98.9% of procedures. Immediate device effectiveness was high and comparable between strategies (100 vs 98.3%; P = 1.0). Procedural duration was shorter with DCS [84 (interquartile range 70.5-111.5) vs 102.5 (78-144) min; P = .019]. In matched analysis (36 pairs), fluoroscopy time, radiation dose, and residual MR at discharge (MR ≤1: 86.1 vs 83.3%; P = .743) were similar. The composite safety endpoint did not differ significantly (P = .436), and no surgical conversions occurred.Conclusions  Dexmedetomidine-based conscious sedation provided procedural effectiveness and safety comparable to GA while improving procedural efficiency. These findings support an individualized anaesthetic strategy and warrant prospective evaluation in contemporary M-TEER practice.
SN  - 2977-8565
ER  -