Half-Integer Spectral Zeros for Leakage Suppression in Fast Transmon Pulses
Abstract
A flat-top transmon pulse with cosine ramps has exact spectral zeros at half-integer values of ramp duration times anharmonicity, (τ|α|=n+1/2), which predict endpoint-leakage minima in the weak-drive regime. For any self-similar one-scale envelope (Ω(t)=Ω_0 f(t/σ)), the non-adiabaticity parameter is exactly degenerate with pulse area, (η_{\rm ref}θ=C_{\rm shape}); an independent ramp timescale (τ) is therefore required. The Fourier amplitude of the resulting envelope at the anharmonicity vanishes at (τ|α|=n+1/2) through destructive interference between the rising and falling edges, independently of plateau length and total pulse duration. Dynamically, the endpoint-leakage amplitude is perturbatively determined by the Fourier component of the envelope weighted by the instantaneous excited-state amplitude. This weighting removes a second, plateau-derived family of envelope zeros not followed by the dynamics. Four-level Duffing simulations using parameters representative of IBM Heron r2 devices collapse the minima onto the half-integer sequence for six pulse durations from 50 to 100 ns, with an RMS deviation of 0.034 in (τ|α|). For four durations resolved on a finer grid, first-order population weighting reduces the positional deviation from 0.0234 to 0.0096. The competing plateau condition does not collapse the data. The residual weak-drive displacement from the half-integers is captured by the population-weighted correction.
Versions
Related
- A Novel q-Derivative Framework with Applications to q-Deformed Thermodynamics and Leakage Suppression in Superconducting Qubits
- Geodesic-based optimal control for leakage suppression in superconducting qubits
- Analytic leakage suppression with a single control field: fast two-qubit gates with tunable couplers
- Ultrabroadband Optical Pulses with Quadratic Spectral Phase Part I: Temporal Form
- Captured weight and boundary leakage bound the error of sample-based spectral functions
BibTeX
@misc{tishin2026halfinteger,
title = {{Half-Integer Spectral Zeros for Leakage Suppression in Fast Transmon Pulses}},
author = {A. M. Tishin},
howpublished = {arXiv},
year = {2026},
month = aug,
doi = {10.48550/arxiv.2605.10578},
eprint = {2605.10578},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2605.10578},
}
RIS
TY - UNPB
TI - Half-Integer Spectral Zeros for Leakage Suppression in Fast Transmon Pulses
AU - A. M. Tishin
PY - 2026
DA - 2026/08/14
PB - arXiv
DO - 10.48550/arxiv.2605.10578
UR - https://arxiv.org/abs/2605.10578
AB - A flat-top transmon pulse with cosine ramps has exact spectral zeros at half-integer values of ramp duration times anharmonicity, (τ|α|=n+1/2), which predict endpoint-leakage minima in the weak-drive regime. For any self-similar one-scale envelope (Ω(t)=Ω_0 f(t/σ)), the non-adiabaticity parameter is exactly degenerate with pulse area, (η_{\rm ref}θ=C_{\rm shape}); an independent ramp timescale (τ) is therefore required. The Fourier amplitude of the resulting envelope at the anharmonicity vanishes at (τ|α|=n+1/2) through destructive interference between the rising and falling edges, independently of plateau length and total pulse duration. Dynamically, the endpoint-leakage amplitude is perturbatively determined by the Fourier component of the envelope weighted by the instantaneous excited-state amplitude. This weighting removes a second, plateau-derived family of envelope zeros not followed by the dynamics. Four-level Duffing simulations using parameters representative of IBM Heron r2 devices collapse the minima onto the half-integer sequence for six pulse durations from 50 to 100 ns, with an RMS deviation of 0.034 in (τ|α|). For four durations resolved on a finer grid, first-order population weighting reduces the positional deviation from 0.0234 to 0.0096. The competing plateau condition does not collapse the data. The residual weak-drive displacement from the half-integers is captured by the population-weighted correction.