Development and Preliminary Validation of the SHUDE Scoring System for Chronic Endometritis in Women With Previous Reproductive Failure Undergoing In Vitro Fertilization Treatment.
- 1Obstetrics and Gynecology, Mahatma Gandhi Institute of Medical Sciences, Warud, IND.
- 2Obstetrics and Gynecology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Medical Sciences (Deemed to Be University), Wardha, IND.
- 3Pathology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Medical Sciences (Deemed to Be University), Wardha, IND.
Abstract
Background Chronic endometritis (CE) has been increasingly recognized in women with infertility and previous reproductive failure, but its diagnosis remains challenging because clinical, hysteroscopic, and histopathological findings may vary between individuals. Hysteroscopy provides direct visualization of the endometrial cavity; however, individual hysteroscopic findings may have limited diagnostic value when considered in isolation. The present study aimed to develop and pilot-test the SHUDE scoring system, a standardized multidomain scoring framework for the structured assessment of CE in women with previous reproductive failure undergoing in vitro fertilization. Methods Following approval from the Institutional Ethics Committee, this methodological study was conducted at a tertiary care center. Thirty eligible women with infertility and a history of reproductive failure were included for the pilot assessment of the scoring system. The SHUDE scoring system comprised six domains: demographic characteristics, reproductive history, clinical history, clinical examination, hysteroscopic findings, and evidence of endometrial tuberculosis. Content validity was assessed using a four-point relevance scale by a multidisciplinary panel of six experts comprising reproductive medicine specialists, obstetricians and gynecologists, and clinicians experienced in diagnostic hysteroscopy. The item-level content validity index (I-CVI) and scale-level content validity index based on the average method (S-CVI/Ave) were calculated. Internal consistency was assessed using Cronbach's alpha. Results The six domains demonstrated acceptable content validity, with I-CVI values ranging from 0.83 to 1.00 and an overall S-CVI/Ave of 0.94. Pilot testing among 30 eligible women yielded a Cronbach's alpha of 0.84, indicating good internal consistency across the six domains. Conclusion The SHUDE scoring system demonstrated high content validity and good internal consistency in this preliminary evaluation. These findings provide initial support for the relevance and coherence of the scoring framework but do not establish its diagnostic accuracy or an optimal diagnostic threshold. Further evaluation in larger, independent populations is required to determine its diagnostic performance, reproducibility, and potential clinical applicability.
Related
- Item Development and Preliminary Validation of the Variability in Adverse Childhood Experiences Scale (VACE)
- New challenges in in vitro fertilization and assisted reproductive technology: Genetic and epigenetic modifications
- Development and preliminary validation of a patient-report experience measure of acute oncology: The PREMAC study
- Development and preliminary validation of the OMFS-PATH questionnaire assessing medical and dental students’ perceptions of Oral and Maxillofacial Surgery as a career
- Development and validation of interpretable machine learning models for predicting cumulative live birth rates in assisted reproductive technology: a SHAP-based analysis.
BibTeX
@article{jain2026development,
title = {{Development and Preliminary Validation of the SHUDE Scoring System for Chronic Endometritis in Women With Previous Reproductive Failure Undergoing In Vitro Fertilization Treatment.}},
author = {Shuchi Jain and Deepti Shrivastava and Sunita Vagha},
journal = {Cureus},
year = {2026},
month = sep,
doi = {10.7759/cureus.116711},
url = {https://europepmc.org/article/MED/42923954},
note = {CC BY},
}
RIS
TY - JOUR
TI - Development and Preliminary Validation of the SHUDE Scoring System for Chronic Endometritis in Women With Previous Reproductive Failure Undergoing In Vitro Fertilization Treatment.
AU - Shuchi Jain
AU - Deepti Shrivastava
AU - Sunita Vagha
PY - 2026
DA - 2026/09/22
JO - Cureus
DO - 10.7759/cureus.116711
UR - https://europepmc.org/article/MED/42923954
AB - Background Chronic endometritis (CE) has been increasingly recognized in women with infertility and previous reproductive failure, but its diagnosis remains challenging because clinical, hysteroscopic, and histopathological findings may vary between individuals. Hysteroscopy provides direct visualization of the endometrial cavity; however, individual hysteroscopic findings may have limited diagnostic value when considered in isolation. The present study aimed to develop and pilot-test the SHUDE scoring system, a standardized multidomain scoring framework for the structured assessment of CE in women with previous reproductive failure undergoing in vitro fertilization. Methods Following approval from the Institutional Ethics Committee, this methodological study was conducted at a tertiary care center. Thirty eligible women with infertility and a history of reproductive failure were included for the pilot assessment of the scoring system. The SHUDE scoring system comprised six domains: demographic characteristics, reproductive history, clinical history, clinical examination, hysteroscopic findings, and evidence of endometrial tuberculosis. Content validity was assessed using a four-point relevance scale by a multidisciplinary panel of six experts comprising reproductive medicine specialists, obstetricians and gynecologists, and clinicians experienced in diagnostic hysteroscopy. The item-level content validity index (I-CVI) and scale-level content validity index based on the average method (S-CVI/Ave) were calculated. Internal consistency was assessed using Cronbach's alpha. Results The six domains demonstrated acceptable content validity, with I-CVI values ranging from 0.83 to 1.00 and an overall S-CVI/Ave of 0.94. Pilot testing among 30 eligible women yielded a Cronbach's alpha of 0.84, indicating good internal consistency across the six domains. Conclusion The SHUDE scoring system demonstrated high content validity and good internal consistency in this preliminary evaluation. These findings provide initial support for the relevance and coherence of the scoring framework but do not establish its diagnostic accuracy or an optimal diagnostic threshold. Further evaluation in larger, independent populations is required to determine its diagnostic performance, reproducibility, and potential clinical applicability.
SN - 2168-8184
ER -