Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 30 min ago
Peer-reviewedCC BY-NC-ND 4.0International Journal of Colorectal Disease

Evaluating the usefulness of 18F-FDG PET/MR in rectal cancer staging: a prospective comparison with histopathological findings

8 affiliations
  1. 1Department of Radiotherapy, Maria Skłodowska-Curie Białystok Oncology Center, Bialystok, 15-027 Poland
  2. 2Department of Radiotherapy I, Maria Skłodowska-Curie Białystok Oncology Center, Bialystok, 15-027 Poland
  3. 3Department of Oncology, Medical University of Bialystok, Białystok, 15-276 Poland
  4. 4Independent Laboratory of Molecular Imaging, Medical University of Bialystok, Bialystok, 15-276 Poland
  5. 5Department of Radiology, Maria Skłodowska-Curie Bialystok Oncology Center, Bialystok, 15-027 Poland
  6. 6Department of Anesthesiology and Intensive Care, National Medical Institute of The Ministry of Interior and Administration, Warsaw, 02-507 Poland
  7. 7Department of Otolaryngology and Maxillofacial Surgery, Jędrzej Śniadecki Regional Specialist Hospital, Bialystok, 15-278 Poland
  8. 8Clinical Research Support Centre, Medical University of Białystok, Białystok, 15-276 Poland

Abstract

Background: Accurate preoperative staging of rectal cancer (RC) is essential for treatment planning. MRI is the standard for local assessment but has limitations in evaluating nodal involvement and tumor deposits. Hybrid PET/MR combines morphological and metabolic imaging and may improve staging accuracy. This study assessed PET/MR performance in RC and regional lymph nodes staging compared with histopathology.

Methods: Sixteen patients with biopsy-proven rectal cancer underwent PET/MR with ^18F-FDG. Tumor size, T stage, nodal status, and tumor deposits were evaluated using multiparametric MR sequences (T1, T2, diffusion-weighted, contrast-enhanced) combined with PET. Imaging findings were compared to histopathological results. Diagnostic performance metrics, including accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), were calculated with corresponding 95% confidence intervals.

Results: PET/MR accurately staged the primary tumor in 81.25% of cases (95% CI: 57.0–93.4), with sensitivity of 100%, specificity of 50.0%, PPV of 76.9%, and NPV of 100% for advanced T-stage assessment. Three cT3 tumors were downstaged to pT2; no tumors were upstaged. For nodal staging based on ESGAR criteria, diagnostic accuracy was 75.0% (95% CI: 50.5–89.8), with sensitivity of 57.1%, specificity of 88.9%, PPV of 80.0%, and NPV of 72.7%. Tumor deposits were not detected on imaging but were present in four specimens. Incidental findings included a biopsy-confirmed breast adenocarcinoma and one benign thyroid lesion.

Conclusion: 18F-FDG PET/MR shows potential for accurate assessment of the primary tumor and reliable exclusion of advanced T-stage disease. However, its performance in nodal staging and tumor deposit detection remains limited. Given the small sample size and potential confounding from preoperative radiotherapy, these findings should be considered hypothesis-generating and require validation in larger prospective cohorts.

Related

  1. Comparison of Cervical Histopathological Findings in Women with High-Risk HPV Types 16 and 18 Versus Other High-Risk HPV Types Following Colposcopy-Guided Biopsy
    Malihe Azadehrah, Fatemeh Khademloo, Somayeh Ghorbani +1
    مجله دانشگاه علوم پزشکی گرگانPeer-reviewedCC BY-NCFull textGeneral medicineDOAJ
  2. Diagnostic Accuracy of Fine Needle Aspiration Cytology in Thyroid Diseases: Comparison with Histopathological Findings in Hawassa, Ethiopia
    A. M. Nisro, T. T. Geremew, A. K. Tadele +5
    medRxivPreprintCC BYFull textEndocrinology & metabolismmedRxiv
  3. A prospective comparison of [⁶⁸Ga]Ga-FAPI-2286 and [¹⁸F]FDG PET/CT for evaluating viable brain metastases in lung cancer.
    Liangqian Tong, Wei Liu, Dong Huang +3
    Cancer imaging : the official publication of the International Cancer Imaging SocietyPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  4. Atrial septal defect associated with suspected left ventricular non-compaction supported by histopathological findings in a child
    Md Ali Osama, Sunil Kumar Malick, Bala Brindha Sargunan +4
    Indian Journal of Thoracic and Cardiovascular SurgeryPeer-reviewedLicence not statedFull textCardiovascular medicinePMC
  5. Histopathological findings in laparoscopic sleeve gastrectomy specimens and their relation to preoperative endoscopy : A retrospective cross-sectional study of 954 patients
    Moaz Abulfaraj, Murad M. Aljiffry, Mohammed F. Alhazmi +8
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{maksim2026evaluating,
  title = {{Evaluating the usefulness of 18F-FDG PET/MR in rectal cancer staging: a prospective comparison with histopathological findings}},
  author = {Rafał Maksim and Dominika Hempel and Małgorzata Mojsak and Justyna Śliwowska-Burzyńska and Konrad Zuzda and Patryk Gugnacki and Iwona Sidorkiewicz and Ewa Sierko},
  journal = {International Journal of Colorectal Disease},
  year = {2026},
  month = jul,
  doi = {10.1007/s00384-026-05192-w},
  url = {https://doi.org/10.1007/s00384-026-05192-w},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Evaluating the usefulness of 18F-FDG PET/MR in rectal cancer staging: a prospective comparison with histopathological findings
AU  - Rafał Maksim
AU  - Dominika Hempel
AU  - Małgorzata Mojsak
AU  - Justyna Śliwowska-Burzyńska
AU  - Konrad Zuzda
AU  - Patryk Gugnacki
AU  - Iwona Sidorkiewicz
AU  - Ewa Sierko
PY  - 2026
DA  - 2026/07/17
JO  - International Journal of Colorectal Disease
DO  - 10.1007/s00384-026-05192-w
UR  - https://doi.org/10.1007/s00384-026-05192-w
AB  - Background: Accurate preoperative staging of rectal cancer (RC) is essential for treatment planning. MRI is the standard for local assessment but has limitations in evaluating nodal involvement and tumor deposits. Hybrid PET/MR combines morphological and metabolic imaging and may improve staging accuracy. This study assessed PET/MR performance in RC and regional lymph nodes staging compared with histopathology.  Methods: Sixteen patients with biopsy-proven rectal cancer underwent PET/MR with ^18F-FDG. Tumor size, T stage, nodal status, and tumor deposits were evaluated using multiparametric MR sequences (T1, T2, diffusion-weighted, contrast-enhanced) combined with PET. Imaging findings were compared to histopathological results. Diagnostic performance metrics, including accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), were calculated with corresponding 95% confidence intervals.  Results: PET/MR accurately staged the primary tumor in 81.25% of cases (95% CI: 57.0–93.4), with sensitivity of 100%, specificity of 50.0%, PPV of 76.9%, and NPV of 100% for advanced T-stage assessment. Three cT3 tumors were downstaged to pT2; no tumors were upstaged. For nodal staging based on ESGAR criteria, diagnostic accuracy was 75.0% (95% CI: 50.5–89.8), with sensitivity of 57.1%, specificity of 88.9%, PPV of 80.0%, and NPV of 72.7%. Tumor deposits were not detected on imaging but were present in four specimens. Incidental findings included a biopsy-confirmed breast adenocarcinoma and one benign thyroid lesion.  Conclusion: 18F-FDG PET/MR shows potential for accurate assessment of the primary tumor and reliable exclusion of advanced T-stage disease. However, its performance in nodal staging and tumor deposit detection remains limited. Given the small sample size and potential confounding from preoperative radiotherapy, these findings should be considered hypothesis-generating and require validation in larger prospective cohorts.
SN  - 0179-1958
SN  - 1432-1262
ER  -