Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 10 min ago
Peer-reviewedCC BY 4.0Resuscitation Plus

Quantifying discrepancies between EMS time intervals in the Swedish Registry for Cardiopulmonary Resuscitation and emergency medical dispatch data: a 10-year analysis

5 affiliations
  1. 1Department of Clinical Science and Education, Södersjukhuset, Centre for Resuscitation Science, Karolinska Institute, Stockholm, Sweden
  2. 2Department of Prehospital Emergency Care, Sahlgrenska University Hospital, Gothenburg, Sweden
  3. 3Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
  4. 4PreHospen-Centre for Prehospital Research, Faculty of Caring Science, Work Life and Social Welfare, University of Borås, Borås, Sweden
  5. 5Uppsala Centre for Prehospital Research, Department of Surgical Sciences – Anesthesiology and Intensive Care, Uppsala University, Uppsala, Sweden

Abstract

Objective: To assess discrepancies between time intervals reported to the Swedish Registry for Cardiopulmonary Resuscitation (SRCR) for out-of-hospital cardiac arrest (OHCA) and those recorded by the dispatch centre between 2015 and 2024.

Methods: In this retrospective observational study, OHCAs reported to the registry were linked to dispatch centre data to correct and validate EMS case numbers. Time interval discrepancies were quantified by comparing the EMS dispatch-to-arrival interval (unit response time) with the call start-to-arrival interval (total response time). Differences between the two sources were estimated using Bayesian quantile regression by modelling the median response-time distribution.

Results: Among 56,969 registry records, 1004 (1.8%) lacked an EMS case number. On a pooled national level, unit response time showed negligible discrepancies between the two sources, with a median difference of 0.3 s (95% CrI −4.1 to 3.9). In contrast, the total response time was systematically shorter in the registry, with a median difference of −80.9 s (95% CrI −84.7 to −77.1). Both time intervals showed large regional variation, with the smallest difference in the Stockholm region.

Conclusion: On a pooled national level, unit response time showed high concordance, whereas total response time was systematically shorter in the registry. Registry time variables, particularly total response time, should be interpreted with caution when evaluating small performance differences.

Related

  1. Public participation in cardiopulmonary resuscitation training: a systematic review and meta-analysis of sociodemographic inequalities and implications for community emergency preparedness
    Pan Pan, Bofu Liu, Yiqin Xia +3
    Frontiers in Public HealthPeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
  2. ‘Pericardial hyperechoic ring’ on point-of-care ultrasound during cardiopulmonary resuscitation
    Koya Akutagawa, Kensuke Ito
    European Heart Journal. Case ReportsPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
  3. Prognostic Impact of Transient Return of Spontaneous Circulation According to Low-Flow Time in Patients with Out-of-Hospital Cardiac Arrest Undergoing Extracorporeal Cardiopulmonary Resuscitation: A Nationwide Cohort Study
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Healthcare providers’ confidence, satisfaction, and perceived preparedness following a multicomponent simulation-based cardiopulmonary resuscitation training program in Gaza
    Madleen Jawad Sobhe Abu Aser, Sharif Jamal Salha, Hasan Husam Ibrahim Al-Balawi
    Frontiers in public healthPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
  5. Facilitating access to cardiopulmonary resuscitation training in high-risk underserved communities: a realist evidence synthesis
    Claire A. Hawkes, Jo-Rycroft Malone, Oisin Keenan +8
    BMC Public HealthPeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
BibTeX
@article{boberg2026quantifying,
  title = {{Quantifying discrepancies between EMS time intervals in the Swedish Registry for Cardiopulmonary Resuscitation and emergency medical dispatch data: a 10-year analysis}},
  author = {Erik Boberg and Carl Magnusson and Douglas Spangler and Fredrik Byrsell and Martin Jonsson},
  journal = {Resuscitation Plus},
  year = {2026},
  month = oct,
  doi = {10.1016/j.resplu.2026.101534},
  url = {https://doi.org/10.1016/j.resplu.2026.101534},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Quantifying discrepancies between EMS time intervals in the Swedish Registry for Cardiopulmonary Resuscitation and emergency medical dispatch data: a 10-year analysis
AU  - Erik Boberg
AU  - Carl Magnusson
AU  - Douglas Spangler
AU  - Fredrik Byrsell
AU  - Martin Jonsson
PY  - 2026
DA  - 2026/10/20
JO  - Resuscitation Plus
DO  - 10.1016/j.resplu.2026.101534
UR  - https://doi.org/10.1016/j.resplu.2026.101534
AB  - Objective: To assess discrepancies between time intervals reported to the Swedish Registry for Cardiopulmonary Resuscitation (SRCR) for out-of-hospital cardiac arrest (OHCA) and those recorded by the dispatch centre between 2015 and 2024.  Methods: In this retrospective observational study, OHCAs reported to the registry were linked to dispatch centre data to correct and validate EMS case numbers. Time interval discrepancies were quantified by comparing the EMS dispatch-to-arrival interval (unit response time) with the call start-to-arrival interval (total response time). Differences between the two sources were estimated using Bayesian quantile regression by modelling the median response-time distribution.  Results: Among 56,969 registry records, 1004 (1.8%) lacked an EMS case number. On a pooled national level, unit response time showed negligible discrepancies between the two sources, with a median difference of 0.3 s (95% CrI −4.1 to 3.9). In contrast, the total response time was systematically shorter in the registry, with a median difference of −80.9 s (95% CrI −84.7 to −77.1). Both time intervals showed large regional variation, with the smallest difference in the Stockholm region.  Conclusion: On a pooled national level, unit response time showed high concordance, whereas total response time was systematically shorter in the registry. Registry time variables, particularly total response time, should be interpreted with caution when evaluating small performance differences.
SN  - 2666-5204
ER  -