Skip to content
DraconiticResearch
Search Sources API
182,469 studies31 sourcesUpdated 6 min ago
Peer-reviewedCC BYEnvironment International

A framework for assessing human internal microplastic exposure through dataset alignment and quality screening

  1. 1Corresponding author.
  2. 2Aquatic Ecology and Water Quality Management Group, Wageningen University and Research, Droevendaalsesteeg 3, 6700 AA Wageningen, Netherlands

Abstract

Determining human microplastic exposure from external intake estimates combined with biodistribution modelling remains highly uncertain because errors propagate across multiple pathways and assumptions. We therefore present a framework for estimating internal human microplastic exposure directly from published measurements in organs, tissues, and bodily fluids. The framework integrates dataset selection, QA/QC screening, and an updated mathematical alignment method incorporating statistical fitting, goodness-of-fit testing, and comparison of alternative particle-size distributions to support cross-compartment comparison and whole-body inference. As a proof of principle, we applied this approach to published human microplastic particle data under two scenarios: an ‘as measured’ scenario and a ‘biologically plausible’ scenario in which particle size distributions were truncated at literature-based accessibility limits. The scenarios produced strongly divergent mean estimates: 159.4 mg (80.9–824; parametric 95 % Monte Carlo interval) under the ‘as measured’ scenario and 0.41 mg (0.22–1.56; parametric 95 % Monte Carlo interval) for the truncated ‘biologically plausible’ scenario. This 388-fold divergence shows that current quantitative inference is dominated by assumptions about the treatment of unusually large particles and data quality. The values should therefore be interpreted as scenario-bounded framework outputs conditional on the currently available, clinically biased dataset, and not as estimates representative of healthy populations or the general population. The framework also yielded apparent, size-dependent organ-to-blood ratios that may serve as provisional benchmarks or hypothesis-generating boundary conditions for future physiologically based kinetic (PBK) model development, but not yet as validated tissue-partitioning constants. Although current data quality limits regulatory-grade quantification, the framework provides a transparent basis for exposure assessment using human monitoring data, for identifying key uncertainties, and for illustrating potential future regulatory application.

Related

  1. Real-time intelligence framework for microplastic monitoring and coastal resilience
    Zuhaib Nishter, Li Gang, Aysha Zahid +5
    iSciencePeer-reviewedCC BYFull textEnvironmental science & pollutionCell PressEurope PMC
  2. Beyond advection: A Lagrangian framework for microplastic transport in depth-averaged shallow water flows
    P Vallés, M Morales-Hernández, Volker Roeber +2
    Journal of Contaminant HydrologyPeer-reviewedCC BY 4.0Full textEnvironmental science & pollutionGeneral mathematicsHAL
  3. TEPI: A transferable street-level framework for assessing urban thermal equity under data constraints
    Yanhuo Luo, Jiayi Luo
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEnvironmental science & pollutionCrossref
  4. A process-based screening framework for coastal reservoirs
    Hsiu-Wen Tso, Han-Lun Wu, Jiun-Huei Jang +6
    Communications Earth & EnvironmentPeer-reviewedCC BY-NC-ND 4.0General earth scienceNatureCrossref
  5. From conceptualization to empirical validation: Developing a framework for assessing local water governance using the Fuzzy Delphi method and confirmatory factor analysis
    Sahra Asadi, Amirhossein Alibaygi
    Environmental and Sustainability IndicatorsPeer-reviewedCC BYFull textHydrology & soilsDOAJ
BibTeX
@article{koelmans2026framework,
  title = {{A framework for assessing human internal microplastic exposure through dataset alignment and quality screening}},
  author = {A.A. Koelmans and Y. Qiu and I. Wardani and E.H.Van Nes and T. Lane},
  journal = {Environment International},
  year = {2026},
  month = oct,
  doi = {10.1016/j.envint.2026.110567},
  url = {https://doi.org/10.1016/j.envint.2026.110567},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - A framework for assessing human internal microplastic exposure through dataset alignment and quality screening
AU  - A.A. Koelmans
AU  - Y. Qiu
AU  - I. Wardani
AU  - E.H.Van Nes
AU  - T. Lane
PY  - 2026
DA  - 2026/10/30
JO  - Environment International
DO  - 10.1016/j.envint.2026.110567
UR  - https://doi.org/10.1016/j.envint.2026.110567
AB  - Determining human microplastic exposure from external intake estimates combined with biodistribution modelling remains highly uncertain because errors propagate across multiple pathways and assumptions. We therefore present a framework for estimating internal human microplastic exposure directly from published measurements in organs, tissues, and bodily fluids. The framework integrates dataset selection, QA/QC screening, and an updated mathematical alignment method incorporating statistical fitting, goodness-of-fit testing, and comparison of alternative particle-size distributions to support cross-compartment comparison and whole-body inference. As a proof of principle, we applied this approach to published human microplastic particle data under two scenarios: an ‘as measured’ scenario and a ‘biologically plausible’ scenario in which particle size distributions were truncated at literature-based accessibility limits. The scenarios produced strongly divergent mean estimates: 159.4 mg (80.9–824; parametric 95 % Monte Carlo interval) under the ‘as measured’ scenario and 0.41 mg (0.22–1.56; parametric 95 % Monte Carlo interval) for the truncated ‘biologically plausible’ scenario. This 388-fold divergence shows that current quantitative inference is dominated by assumptions about the treatment of unusually large particles and data quality. The values should therefore be interpreted as scenario-bounded framework outputs conditional on the currently available, clinically biased dataset, and not as estimates representative of healthy populations or the general population. The framework also yielded apparent, size-dependent organ-to-blood ratios that may serve as provisional benchmarks or hypothesis-generating boundary conditions for future physiologically based kinetic (PBK) model development, but not yet as validated tissue-partitioning constants. Although current data quality limits regulatory-grade quantification, the framework provides a transparent basis for exposure assessment using human monitoring data, for identifying key uncertainties, and for illustrating potential future regulatory application.
SN  - 0160-4120
ER  -