Wearable acoustic cardiography for detection of left ventricular and valvular dysfunction: a prospective diagnostic accuracy study
4 affiliations
- 1Department of Anesthesiology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- 2Department of Cardiac Function, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- 3Department of engineering, Wenxin Tech Inc, Fuzhou, Fujian, China
- 4Department of Cardiology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
Abstract
Background: Preoperative cardiac evaluation based on history and physical examination is subjective, risking delayed diagnosis or excessive echocardiography. Acoustic cardiography (ACG) synchronizes ECG and heart sound analysis for rapid point-of-care cardiac screening. We evaluated the diagnostic accuracy of wearable ACG for left ventricular dysfunction, significant valvular dysfunction, and the consistency of ACG-aided preoperative risk assessment with expert consensus.
Methods: This prospective single-center study enrolled consecutive patients undergoing major elective non-cardiac surgery. Echocardiography served as the reference standard; the primary endpoint was LVEF <40%.
Results: Among 262 patients, ACG showed excellent performance for LVEF <40% (AUC=0.979, sensitivity 93.3%, specificity 96.4%). It achieved substantial agreement with echocardiography for significant valvular dysfunction (κ=0.69). Adding ACG improved consistency with expert consensus versus physical examination alone (κ=0.71 vs 0.55).
Conclusions: Wearable ACG provides high accuracy for preoperative screening of systolic and valvular dysfunction. It facilitates targeted echocardiography referral. Further trials are needed to verify its impact on referral decisions and perioperative outcomes.
Trial registration: ChiCTR2300073695.
Related
- Cancer Therapy-Induced Right Ventricular Systolic and Diastolic Dysfunction Assessed Using Conventional Echocardiographic Indices: A Prospective Observational Study
- Novel Large Language Model-Based Detection of Echocardiographic Markers of Right Ventricular Dysfunction
- Single lead electrocardiographic detection of left ventricular systolic dysfunction in pediatric and congenital heart disease
- Rapid direct-from-urine growth detection to triage culture-negative urine: a prospective diagnostic accuracy study of a two-tube nitrate-reduction and bromothymol blue assay (SIBURI/SIBURI+)
- Multimodal Hyperspectroscopy with LuViva® for Detection of CIN2+ in Women Referred for Colposcopy: A Prospective Diagnostic Accuracy Study
BibTeX
@article{xie2026wearable,
title = {{Wearable acoustic cardiography for detection of left ventricular and valvular dysfunction: a prospective diagnostic accuracy study}},
author = {Shouyu Xie and Yulan Wu and Ruoying Li and Yun Cai and Jingjuan Huang and Jingxiang Wu},
journal = {Annals of Medicine},
year = {2026},
month = nov,
doi = {10.1080/07853890.2026.2764469},
url = {https://doi.org/10.1080/07853890.2026.2764469},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Wearable acoustic cardiography for detection of left ventricular and valvular dysfunction: a prospective diagnostic accuracy study
AU - Shouyu Xie
AU - Yulan Wu
AU - Ruoying Li
AU - Yun Cai
AU - Jingjuan Huang
AU - Jingxiang Wu
PY - 2026
DA - 2026/11/17
JO - Annals of Medicine
DO - 10.1080/07853890.2026.2764469
UR - https://doi.org/10.1080/07853890.2026.2764469
AB - Background: Preoperative cardiac evaluation based on history and physical examination is subjective, risking delayed diagnosis or excessive echocardiography. Acoustic cardiography (ACG) synchronizes ECG and heart sound analysis for rapid point-of-care cardiac screening. We evaluated the diagnostic accuracy of wearable ACG for left ventricular dysfunction, significant valvular dysfunction, and the consistency of ACG-aided preoperative risk assessment with expert consensus. Methods: This prospective single-center study enrolled consecutive patients undergoing major elective non-cardiac surgery. Echocardiography served as the reference standard; the primary endpoint was LVEF <40%. Results: Among 262 patients, ACG showed excellent performance for LVEF <40% (AUC=0.979, sensitivity 93.3%, specificity 96.4%). It achieved substantial agreement with echocardiography for significant valvular dysfunction (κ=0.69). Adding ACG improved consistency with expert consensus versus physical examination alone (κ=0.71 vs 0.55). Conclusions: Wearable ACG provides high accuracy for preoperative screening of systolic and valvular dysfunction. It facilitates targeted echocardiography referral. Further trials are needed to verify its impact on referral decisions and perioperative outcomes. Trial registration: ChiCTR2300073695.
SN - 0785-3890
SN - 1365-2060
ER -