Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 14 min ago
PreprintCC BY 4.0arXiv

Beyond Spectroscopic Strong Coupling: Operational Benchmarks for Cavity-to-Magnon Quantum Transfer

Abstract

Normal-mode splitting reveals coherent cavity--magnon hybridization but does not certify finite-time quantum-state transfer. We describe quantum transfer in a passive, linear cavity--magnon system coupled to thermal reservoirs as a thermal-loss channel specified by its coherent transmissivity η and output-referred thermal population ν. For single-rail qubits, we calculate the phase-corrected average fidelity and compare it with the deterministic measure-and-prepare benchmark of 2/3. A Bell pair shared by the cavity and an isolated reference retains reference--magnon entanglement if and only if η>ν. An input squeezed vacuum of strength r yields sub-vacuum magnon fluctuations if and only if ν<η(1−e−2r)/2. When the initial magnon and both reservoirs have the same occupation, an analytically determined peak-transmissivity time optimizes all three tasks. These task-dependent benchmarks show that a conventional linewidth-based strong-coupling criterion does not guarantee quantum-transfer performance. Conversely, entanglement or squeezing can survive below that spectroscopic reference when the added noise is sufficiently low. These benchmarks provide quantitative targets for transfer timing and thermal-noise control in intracavity-to-magnon quantum interfaces.

Related

  1. Attainable Boundaries versus Operational Equivalence: Dual Benchmarks for the Hierarchical Assessment of Quantum Resources
    Sunho Kim, Chunhe Xiong, Junde Wu
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
  2. A uniform elliptic reduction, an order-matching criterion, and precision benchmarks for the strong-coupling Birman-Schwinger analysis of the lattice three-boson trimer
    Mikhail Dolgopolov
    arXivPreprintarXiv licenceFull textAnalysis & PDEsMathematical physicsarXiv
  3. Spectroscopic signatures of mode-selective electron-phonon coupling in transient reflectivity change on charge-density-wave TiSe2
    Yu Mizukoshi, Muneaki Hase
    arXivPreprintCC BY-NC-ND 4.0Full textCondensed matterarXiv
  4. Neutrino Spin--Flavor Dynamics and Quantum Rabi Model: Spectral Correspondence and QRM Benchmarks
    Saber Zarrinkamar
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  5. Representation Geometry and Inductive Biases in Quantum Classifiers across Classical Visual Benchmarks
    Yu Yamaoka, Weng Ian Chan, Kosuke Mitarai
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
BibTeX
@misc{xinyi2026beyond,
  title = {{Beyond Spectroscopic Strong Coupling: Operational Benchmarks for Cavity-to-Magnon Quantum Transfer}},
  author = {Huang Xinyi and Zhang Xiang and Zhao Dongxing},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.09921},
  eprint = {2610.09921},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.09921},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Beyond Spectroscopic Strong Coupling: Operational Benchmarks for Cavity-to-Magnon Quantum Transfer
AU  - Huang Xinyi
AU  - Zhang Xiang
AU  - Zhao Dongxing
PY  - 2026
DA  - 2026/10/07
PB  - arXiv
DO  - 10.48550/arxiv.2610.09921
UR  - https://arxiv.org/abs/2610.09921
AB  - Normal-mode splitting reveals coherent cavity--magnon hybridization but does not certify finite-time quantum-state transfer. We describe quantum transfer in a passive, linear cavity--magnon system coupled to thermal reservoirs as a thermal-loss channel specified by its coherent transmissivity η and output-referred thermal population ν. For single-rail qubits, we calculate the phase-corrected average fidelity and compare it with the deterministic measure-and-prepare benchmark of 2/3. A Bell pair shared by the cavity and an isolated reference retains reference--magnon entanglement if and only if η>ν. An input squeezed vacuum of strength r yields sub-vacuum magnon fluctuations if and only if ν<η(1−e^−2r)/2. When the initial magnon and both reservoirs have the same occupation, an analytically determined peak-transmissivity time optimizes all three tasks. These task-dependent benchmarks show that a conventional linewidth-based strong-coupling criterion does not guarantee quantum-transfer performance. Conversely, entanglement or squeezing can survive below that spectroscopic reference when the added noise is sufficiently low. These benchmarks provide quantitative targets for transfer timing and thermal-noise control in intracavity-to-magnon quantum interfaces.
ER  -