PreprintCC BY-NC-ND 4.0arXiv
A Six-Quadrupole Diamagnetic Suspension Architecture for Ultra-Sensitive Space Accelerometry
Abstract
This paper proposes a novel inertial sensor based on a solid diamagnetic cubic test mass passively suspended by a symmetric configuration of six magnetic quadrupoles. Designed specifically for microgravity environments, this system eliminates the mechanical noise and hysteresis inherent in elastic suspensions, as well as the complexity associated with electrostatic suspension systems. We provide an analysis of the magnetic intrinsic noise floor imposed by eddy current damping, alongside ground-based preliminary experimental results demonstrating potential sensitivities in the order of the 10−10 m/s2/√(Hz) regime.
Related
- Electromagnetic filament coalescence as magnetic island merging with diamagnetic effects
- Ab initio calculated diamagnetic and paramagnetic susceptibility of carbonate minerals
- Ab initio anatomy of quadrupole correlations in 16O and 20Ne
- Post-Newtonian secular dynamics of hierarchical triples II. Canonical derivation of the 1PN × quadrupole cross terms and of the quadrupole-squared term
- Stochastic switching in quadrupole-trap-based levitodynamic systems
BibTeX
@misc{pisani2026sixquadrupole,
title = {{A Six-Quadrupole Diamagnetic Suspension Architecture for Ultra-Sensitive Space Accelerometry}},
author = {Marco Pisani and Edoardo Dalla Ricca and Carlo Paolo Sasso and Massimo Zucco},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2609.09914},
eprint = {2609.09914},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2609.09914},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - UNPB
TI - A Six-Quadrupole Diamagnetic Suspension Architecture for Ultra-Sensitive Space Accelerometry
AU - Marco Pisani
AU - Edoardo Dalla Ricca
AU - Carlo Paolo Sasso
AU - Massimo Zucco
PY - 2026
DA - 2026/09/09
PB - arXiv
DO - 10.48550/arxiv.2609.09914
UR - https://arxiv.org/abs/2609.09914
AB - This paper proposes a novel inertial sensor based on a solid diamagnetic cubic test mass passively suspended by a symmetric configuration of six magnetic quadrupoles. Designed specifically for microgravity environments, this system eliminates the mechanical noise and hysteresis inherent in elastic suspensions, as well as the complexity associated with electrostatic suspension systems. We provide an analysis of the magnetic intrinsic noise floor imposed by eddy current damping, alongside ground-based preliminary experimental results demonstrating potential sensitivities in the order of the 10^−10 m/s^2/√(Hz) regime.
ER -