Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI
Abstract
Purpose: To complement 1.5-minute measurements of common tensor-valued diffusion MRI (dMRI) markers with rapid constrained fitting. Methods: Fast dMRI protocols for obtaining rotational invariants of the cumulant expansion (RICE) were paired with constrained weighted linear least squares (CWLLS) to stabilize the more fragile WLLS fit. A compact constraint set was formulated, including a novel mean-dependent upper bound on total diffusional variance. Evaluation used diffusion tensor distribution (DTD) simulations, healthy-volunteer data with a resolution-dependent SNR experiment, and a glioma patient dataset. A 5-minute q-space trajectory imaging (QTI) protocol served as a reference. Results: Across experiments, CWLLS reduced unphysical estimates and fit outliers in parameters such as microscopic FA and isotropic diffusivity variance. In simulations, it narrowed error distributions most clearly in the CSF-dominant case, while some metrics showed a bias-variance trade-off. In vivo, CWLLS removed negative variance estimates, truncated out-of-bounds tails, and reduced artifacts in fluid-contaminated voxels while preserving anatomical contrast. It also retained more stable maps than WLLS at higher resolution, although both estimators degraded in the lowest-SNR setting. Notably, the new mean-dependent variance bound was violated in 15.4% of voxels in the patient dataset, accounting for nearly half of the 32.7% that violated at least one constraint. Healthy-volunteer benchmarking showed that CWLLS completed in under 30 seconds. The constrained QTI fit required 72 minutes, making CWLLS 160 times faster. Conclusion: CWLLS for fast RICE yielded high-quality parameter maps at an online-ready computational cost. This may enhance the reliability of dMRI tissue characterization and strengthen the path toward clinical translation.
Related
- Constrained coupled-cluster computations yield negative-parity rotational bands
- Hierarchy of time scales in kinetically constrained models via stochastic-generator expansion
- Constrained Optimization of Higher-Order Cluster-Expansion Hamiltonians for Alloys Using Simulated Bifurcation
- First-principles transition-state tensorial cluster expansion of vacancy diffusion in Ta-W beyond the kinetically-resolved activation approximation
- Channel-Constrained Information Scheduling for Quantum Diffusion
BibTeX
@misc{yu2026constrained,
title = {{Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI}},
author = {Jinyang Yu and Oliver Gödicke and Frederik B. Laun and Obada T. Alhalabi and Iris A. Kohler and Jürgen Hesser and Sandro M. Krieg and Bogdana Suchorska and Heinz-Peter Schlemmer and Mark E. Ladd and David Bonekamp and Johann M. E. Jende and Tristan A. Kuder},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2608.27212},
eprint = {2608.27212},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2608.27212},
}
RIS
TY - UNPB
TI - Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI
AU - Jinyang Yu
AU - Oliver Gödicke
AU - Frederik B. Laun
AU - Obada T. Alhalabi
AU - Iris A. Kohler
AU - Jürgen Hesser
AU - Sandro M. Krieg
AU - Bogdana Suchorska
AU - Heinz-Peter Schlemmer
AU - Mark E. Ladd
AU - David Bonekamp
AU - Johann M. E. Jende
AU - Tristan A. Kuder
PY - 2026
DA - 2026/09/17
PB - arXiv
DO - 10.48550/arxiv.2608.27212
UR - https://arxiv.org/abs/2608.27212
AB - Purpose: To complement 1.5-minute measurements of common tensor-valued diffusion MRI (dMRI) markers with rapid constrained fitting. Methods: Fast dMRI protocols for obtaining rotational invariants of the cumulant expansion (RICE) were paired with constrained weighted linear least squares (CWLLS) to stabilize the more fragile WLLS fit. A compact constraint set was formulated, including a novel mean-dependent upper bound on total diffusional variance. Evaluation used diffusion tensor distribution (DTD) simulations, healthy-volunteer data with a resolution-dependent SNR experiment, and a glioma patient dataset. A 5-minute q-space trajectory imaging (QTI) protocol served as a reference. Results: Across experiments, CWLLS reduced unphysical estimates and fit outliers in parameters such as microscopic FA and isotropic diffusivity variance. In simulations, it narrowed error distributions most clearly in the CSF-dominant case, while some metrics showed a bias-variance trade-off. In vivo, CWLLS removed negative variance estimates, truncated out-of-bounds tails, and reduced artifacts in fluid-contaminated voxels while preserving anatomical contrast. It also retained more stable maps than WLLS at higher resolution, although both estimators degraded in the lowest-SNR setting. Notably, the new mean-dependent variance bound was violated in 15.4% of voxels in the patient dataset, accounting for nearly half of the 32.7% that violated at least one constraint. Healthy-volunteer benchmarking showed that CWLLS completed in under 30 seconds. The constrained QTI fit required 72 minutes, making CWLLS 160 times faster. Conclusion: CWLLS for fast RICE yielded high-quality parameter maps at an online-ready computational cost. This may enhance the reliability of dMRI tissue characterization and strengthen the path toward clinical translation.
ER -