Skip to content
DraconiticResearch
Search Sources API
186,125 studies31 sourcesUpdated 46 min ago
PreprintarXiv licencearXiv

Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI

1 more authors

Abstract

Purpose: To complement 1.5-minute measurements of common tensor-valued diffusion MRI (dMRI) markers with rapid constrained fitting. Methods: Fast dMRI protocols for obtaining rotational invariants of the cumulant expansion (RICE) were paired with constrained weighted linear least squares (CWLLS) to stabilize the more fragile WLLS fit. A compact constraint set was formulated, including a novel mean-dependent upper bound on total diffusional variance. Evaluation used diffusion tensor distribution (DTD) simulations, healthy-volunteer data with a resolution-dependent SNR experiment, and a glioma patient dataset. A 5-minute q-space trajectory imaging (QTI) protocol served as a reference. Results: Across experiments, CWLLS reduced unphysical estimates and fit outliers in parameters such as microscopic FA and isotropic diffusivity variance. In simulations, it narrowed error distributions most clearly in the CSF-dominant case, while some metrics showed a bias-variance trade-off. In vivo, CWLLS removed negative variance estimates, truncated out-of-bounds tails, and reduced artifacts in fluid-contaminated voxels while preserving anatomical contrast. It also retained more stable maps than WLLS at higher resolution, although both estimators degraded in the lowest-SNR setting. Notably, the new mean-dependent variance bound was violated in 15.4% of voxels in the patient dataset, accounting for nearly half of the 32.7% that violated at least one constraint. Healthy-volunteer benchmarking showed that CWLLS completed in under 30 seconds. The constrained QTI fit required 72 minutes, making CWLLS 160 times faster. Conclusion: CWLLS for fast RICE yielded high-quality parameter maps at an online-ready computational cost. This may enhance the reliability of dMRI tissue characterization and strengthen the path toward clinical translation.

Related

  1. Constrained coupled-cluster computations yield negative-parity rotational bands
    Gaute Hagen, Benjamin Bally, Thomas Papenbrock
    arXivPreprintCC BY 4.0Full textNuclear physicsarXiv
  2. Hierarchy of time scales in kinetically constrained models via stochastic-generator expansion
    Vanja Marić, Juan P. Garrahan, Lenart Zadnik
    arXivPreprintCC BY 4.0Full textStatistical & nonlinear physicsarXiv
  3. Constrained Optimization of Higher-Order Cluster-Expansion Hamiltonians for Alloys Using Simulated Bifurcation
    Kazuhide Ichikawa, Satoru Ohuchi, Tomoyasu Yokoyama +2
    arXivPreprintarXiv licenceFull textComputational physicsCondensed matterarXiv
  4. First-principles transition-state tensorial cluster expansion of vacancy diffusion in Ta-W beyond the kinetically-resolved activation approximation
    Jacob Jeffries, Brianna Sebastian-Olazabal, Enrique Martinez
    arXivPreprintCC BY-NC-ND 4.0Full textCondensed matterarXiv
  5. Channel-Constrained Information Scheduling for Quantum Diffusion
    Qipeng Qian, Yuntao Qian
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
BibTeX
@misc{yu2026constrained,
  title = {{Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI}},
  author = {Jinyang Yu and Oliver Gödicke and Frederik B. Laun and Obada T. Alhalabi and Iris A. Kohler and Jürgen Hesser and Sandro M. Krieg and Bogdana Suchorska and Heinz-Peter Schlemmer and Mark E. Ladd and David Bonekamp and Johann M. E. Jende and Tristan A. Kuder},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2608.27212},
  eprint = {2608.27212},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2608.27212},
}
RIS
TY  - UNPB
TI  - Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI
AU  - Jinyang Yu
AU  - Oliver Gödicke
AU  - Frederik B. Laun
AU  - Obada T. Alhalabi
AU  - Iris A. Kohler
AU  - Jürgen Hesser
AU  - Sandro M. Krieg
AU  - Bogdana Suchorska
AU  - Heinz-Peter Schlemmer
AU  - Mark E. Ladd
AU  - David Bonekamp
AU  - Johann M. E. Jende
AU  - Tristan A. Kuder
PY  - 2026
DA  - 2026/09/17
PB  - arXiv
DO  - 10.48550/arxiv.2608.27212
UR  - https://arxiv.org/abs/2608.27212
AB  - Purpose: To complement 1.5-minute measurements of common tensor-valued diffusion MRI (dMRI) markers with rapid constrained fitting. Methods: Fast dMRI protocols for obtaining rotational invariants of the cumulant expansion (RICE) were paired with constrained weighted linear least squares (CWLLS) to stabilize the more fragile WLLS fit. A compact constraint set was formulated, including a novel mean-dependent upper bound on total diffusional variance. Evaluation used diffusion tensor distribution (DTD) simulations, healthy-volunteer data with a resolution-dependent SNR experiment, and a glioma patient dataset. A 5-minute q-space trajectory imaging (QTI) protocol served as a reference. Results: Across experiments, CWLLS reduced unphysical estimates and fit outliers in parameters such as microscopic FA and isotropic diffusivity variance. In simulations, it narrowed error distributions most clearly in the CSF-dominant case, while some metrics showed a bias-variance trade-off. In vivo, CWLLS removed negative variance estimates, truncated out-of-bounds tails, and reduced artifacts in fluid-contaminated voxels while preserving anatomical contrast. It also retained more stable maps than WLLS at higher resolution, although both estimators degraded in the lowest-SNR setting. Notably, the new mean-dependent variance bound was violated in 15.4% of voxels in the patient dataset, accounting for nearly half of the 32.7% that violated at least one constraint. Healthy-volunteer benchmarking showed that CWLLS completed in under 30 seconds. The constrained QTI fit required 72 minutes, making CWLLS 160 times faster. Conclusion: CWLLS for fast RICE yielded high-quality parameter maps at an online-ready computational cost. This may enhance the reliability of dMRI tissue characterization and strengthen the path toward clinical translation.
ER  -