Quantitative CT definition of solid components in pulmonary ground-glass nodules: a pixel-level annotation-based development and internal validation study.
5 affiliations
- 1Department of Thoracic Surgery, West China Hospital, Sichuan University, Chengdu, China.
- 2West China School of Medicine, Sichuan University, Chengdu, China.
- 3Institute of Thoracic Oncology, Frontiers Science Center for Disease-Related Molecular Network, West China Hospital of Sichuan University, Chengdu, China.
- 4College of Computer Science, Sichuan University, Chengdu, China.
- 5School of Artificial Intelligence, Sichuan University, Chengdu, China.
Abstract
Solid-component assessment in pulmonary ground-glass nodules (GGNs) remains subjective, and no universally accepted computed tomography (CT) attenuation threshold exists. Fixed cutoffs may not account for inter-lesion variation in baseline ground-glass opacity (GGO) attenuation. We aimed to develop and internally validate lesion-adaptive quantitative CT definitions of the solid component using three-dimensional pixel-level expert annotations as the imaging reference standard. This retrospective single-center methodological study included 170 unique patients with 170 surgically resected stage I lung adenocarcinoma-spectrum GGNs from March 2015 through July 2018 and each patient contributed one target lesion. All examinations were acquired on the same 256-row CT scanner, and venous-phase 1-mm images reconstructed with medium-strength deep learning image reconstruction were used for analysis. Each lesion was independently annotated by at least two experienced thoracic surgeons, with Dice-based adjudication and senior review. Patients were randomly allocated to training (n=120) and internal validation (n=50) cohorts. Nine prespecified study methods and three literature-based fixed thresholds were evaluated at pixel and lesion levels. The training and validation cohorts had median lesion sizes of 1.2 and 1.3 cm and median annotated solid-component proportions of 0.324 and 0.319, respectively. The GGO mean plus ratio method achieved the highest area under the receiver operating characteristic (ROC) curve [AUC, 0.848; 95% confidence interval (CI): 0.841-0.856], with sensitivity of 0.732, specificity of 0.815, and F1/Dice of 0.760. The GGO mean plus difference method yielded the highest lesion-level coefficient of determination (R2, 0.744; 95% CI: 0.499-0.889), whereas the ratio method yielded the lowest root mean square error (RMSE, 0.105) and mean absolute error (MAE, 0.088). Pairwise DeLong testing showed no statistically significant AUC difference among the three top-performing GGO-referenced methods. In this single-center internal validation study, lesion-adaptive GGO-referenced methods showed more favorable overall pixel-level discrimination and lesion-level agreement than universal fixed thresholds or lesion-summary estimators. These rules should be considered developmental quantitative methods and require multicenter external validation across CT platforms and reconstruction protocols before routine clinical use.
Related
- Development and Initial Validation of a Statistical Image Analysis Framework for Quantitative Bone SPECT/CT in Patients with Prostate Cancer
- A 2-year prognostic assessment of patients with coronary borderline lesions based on three-vessel quantitative flow ratio and the development and internal validation of a risk prediction nomogram
- Histologically Validated Ex Vivo Characterization of Intraplaque Hemorrhage and Lipid Components Using Quantitative Susceptibility Mapping
- Neuroprotective Potential of the Edible Seaweed Pterocladiella capillacea: Bioactivity Coupled LC-MS/MS, Metabolomics Annotation, Validation, and Network Pharmacology
- Early mobility to improVE health outcomes following cardiac surgery (EVE) clinical trial development: findings from workshop 2-co-created definition and prioritized barriers, facilitators and outcome and experience measures.
BibTeX
@article{chen2026quantitative,
title = {{Quantitative CT definition of solid components in pulmonary ground-glass nodules: a pixel-level annotation-based development and internal validation study.}},
author = {Yuhao Chen and Nan Chen and Yuhuan Ye and Han Zhang and Wanting Xia and Kunhao Wu and Nanzhi Luo and Zhenyi Niu and Le Yi and Qiang Pu and Xiuyuan Xu and Lunxu Liu},
journal = {Translational lung cancer research},
year = {2026},
month = sep,
doi = {10.21037/tlcr-2026-0841},
url = {https://europepmc.org/article/MED/42999425},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Quantitative CT definition of solid components in pulmonary ground-glass nodules: a pixel-level annotation-based development and internal validation study.
AU - Yuhao Chen
AU - Nan Chen
AU - Yuhuan Ye
AU - Han Zhang
AU - Wanting Xia
AU - Kunhao Wu
AU - Nanzhi Luo
AU - Zhenyi Niu
AU - Le Yi
AU - Qiang Pu
AU - Xiuyuan Xu
AU - Lunxu Liu
PY - 2026
DA - 2026/09/29
JO - Translational lung cancer research
DO - 10.21037/tlcr-2026-0841
UR - https://europepmc.org/article/MED/42999425
AB - Solid-component assessment in pulmonary ground-glass nodules (GGNs) remains subjective, and no universally accepted computed tomography (CT) attenuation threshold exists. Fixed cutoffs may not account for inter-lesion variation in baseline ground-glass opacity (GGO) attenuation. We aimed to develop and internally validate lesion-adaptive quantitative CT definitions of the solid component using three-dimensional pixel-level expert annotations as the imaging reference standard. This retrospective single-center methodological study included 170 unique patients with 170 surgically resected stage I lung adenocarcinoma-spectrum GGNs from March 2015 through July 2018 and each patient contributed one target lesion. All examinations were acquired on the same 256-row CT scanner, and venous-phase 1-mm images reconstructed with medium-strength deep learning image reconstruction were used for analysis. Each lesion was independently annotated by at least two experienced thoracic surgeons, with Dice-based adjudication and senior review. Patients were randomly allocated to training (n=120) and internal validation (n=50) cohorts. Nine prespecified study methods and three literature-based fixed thresholds were evaluated at pixel and lesion levels. The training and validation cohorts had median lesion sizes of 1.2 and 1.3 cm and median annotated solid-component proportions of 0.324 and 0.319, respectively. The GGO mean plus ratio method achieved the highest area under the receiver operating characteristic (ROC) curve [AUC, 0.848; 95% confidence interval (CI): 0.841-0.856], with sensitivity of 0.732, specificity of 0.815, and F1/Dice of 0.760. The GGO mean plus difference method yielded the highest lesion-level coefficient of determination (R2, 0.744; 95% CI: 0.499-0.889), whereas the ratio method yielded the lowest root mean square error (RMSE, 0.105) and mean absolute error (MAE, 0.088). Pairwise DeLong testing showed no statistically significant AUC difference among the three top-performing GGO-referenced methods. In this single-center internal validation study, lesion-adaptive GGO-referenced methods showed more favorable overall pixel-level discrimination and lesion-level agreement than universal fixed thresholds or lesion-summary estimators. These rules should be considered developmental quantitative methods and require multicenter external validation across CT platforms and reconstruction protocols before routine clinical use.
SN - 2218-6751
SN - 2226-4477
ER -