Skip to content
DraconiticResearch
Search Sources API
182,460 studies31 sourcesUpdated 17 min ago
PreprintCC BY-NCbioRxiv

Comparing advanced interference suppression algorithms for OPM-MEG

  1. 1Karolinska Institute

Abstract

On-scalp MEG using optically pumped magnetometers (OPMs) have become more widespread with the recent introduction of the first whole-head systems that offer comparable spatial sampling to conventional MEG systems. For these systems to become truly useful in neuroscience and clinically they need to be able to deal with the kind of interference seen in typical lab and hospital environments - both environmental and participant related (e.g., dental wires). Conventional MEG uses sophisticated interference suppression algorithms to deal with this, but these tend to become instable at lower sensor counts - which makes up the majority of OPM-MEG systems to date. Alternative methods for OPM-MEG are needed. Several alternative algorithms have been proposed but a clear comparison between them is lacking. Here, we test and compare 5 of the most promising candidates, namely homogenous field correction (HFC), adaptive multipole models (AMM), signal space projection (SSP), signal space separation (SSS) and its iterative implementation (SSSit) using simulations and data recorded with a whole-head system. Recorded data includes a participant with dental wire - an especially difficult to deal with source of interference. We find that all algorithms tested achieve good interference suppression with dual-axis data. With single-axis data, SSS exhibited stability problems and several algorithms showed large signal loss (up to ~25%). SSP, temporal SSS and temporal AMM were able to suppress the dental artifact. Finally, we provide recommendations for researchers to determine help decide how to deal with interference in their OPM-MEG studies.

Related

  1. Predicting Elephant Crop-Raiding with Machine Learning to Inform Conservation Planning: A Case Study Comparing the Performance and Tradeoffs of GeoAI Algorithms in Northwestern Zimbabwe
    Katherine Elizabeth Markham, Sergio Bernardes, Ferrel V. Osborn +6
    EarthArXivPreprintCC BY-NC 4.0Full textEcologyEarthArXiv
  2. The Role of the Left Inferior Frontal Gyrus in Resolving Immediate and Carryover Semantic Interference During Picture Naming
    D. Y. Harvey, H. Stoll, R. H. Hamilton
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  3. Comparing pest survey methods through detection probability: seasonal and abundance-dependent detection of spotted lanternfly (Lycorma delicatula, Hemiptera: Fulgoridae)
    J. A. Keller, M. R. Helmus, K. Hoover
    bioRxivPreprintAll rights reservedFull textEcologybioRxiv
  4. Comparing prescribing and spending across originator, follow-on, and interchangeable biosimilar insulin glargine: Opportunities to improve uptake of biosimilar medications
    Lucille M. Abrams, Kylee Funk, Joel F. Farley
    Journal of Managed Care & Specialty PharmacyPeer-reviewedLicence not statedFull textImmunologyPMC
  5. RSV & rhinovirus coinfection order dictates outcome via type III interferon-mediated interference in infant respiratory epithelium
    E. M. Schultz, G. M. Aloisio, A. Murray +12
    bioRxivPreprintAll rights reservedFull textMicrobiologybioRxiv
BibTeX
@misc{pfeiffer2026comparing,
  title = {{Comparing advanced interference suppression algorithms for OPM-MEG}},
  author = {C. Pfeiffer and D. Lundqvist},
  howpublished = {bioRxiv},
  year = {2026},
  month = sep,
  doi = {10.64898/2026.09.08.750027},
  url = {https://www.biorxiv.org/content/10.64898/2026.09.08.750027v1},
  note = {CC BY-NC},
}
RIS
TY  - UNPB
TI  - Comparing advanced interference suppression algorithms for OPM-MEG
AU  - C. Pfeiffer
AU  - D. Lundqvist
PY  - 2026
DA  - 2026/09/08
PB  - bioRxiv
DO  - 10.64898/2026.09.08.750027
UR  - https://www.biorxiv.org/content/10.64898/2026.09.08.750027v1
AB  - On-scalp MEG using optically pumped magnetometers (OPMs) have become more widespread with the recent introduction of the first whole-head systems that offer comparable spatial sampling to conventional MEG systems. For these systems to become truly useful in neuroscience and clinically they need to be able to deal with the kind of interference seen in typical lab and hospital environments - both environmental and participant related (e.g., dental wires). Conventional MEG uses sophisticated interference suppression algorithms to deal with this, but these tend to become instable at lower sensor counts - which makes up the majority of OPM-MEG systems to date. Alternative methods for OPM-MEG are needed. Several alternative algorithms have been proposed but a clear comparison between them is lacking. Here, we test and compare 5 of the most promising candidates, namely homogenous field correction (HFC), adaptive multipole models (AMM), signal space projection (SSP), signal space separation (SSS) and its iterative implementation (SSSit) using simulations and data recorded with a whole-head system. Recorded data includes a participant with dental wire - an especially difficult to deal with source of interference. We find that all algorithms tested achieve good interference suppression with dual-axis data. With single-axis data, SSS exhibited stability problems and several algorithms showed large signal loss (up to ~25%). SSP, temporal SSS and temporal AMM were able to suppress the dental artifact. Finally, we provide recommendations for researchers to determine help decide how to deal with interference in their OPM-MEG studies.
ER  -