Skip to content
DraconiticResearch
Search Sources API
197,693 studies31 sourcesUpdated 12 min ago
Peer-reviewedCC BY-NC-NDPlastic and reconstructive surgery. Global open

Serasynth Mesh BR Pocket in Prepectoral Direct-to-implant and Tissue-expander Breast Reconstruction: A Retrospective Single-center Analysis.

4 affiliations
  1. 1From the Department of Plastic, Reconstructive and Aesthetic Surgery, Hospital of the Brothers of St. John of God, Paracelsus Medical University, Salzburg, Austria.
  2. 2Department of Plastic Surgery, Community Hospital Feldkirch, Feldkirch, Austria.
  3. 3Department of Ophthalmology and Optometry, Paracelsus Medical University Salzburg, Salzburg, Austria.
  4. 4Research Program Experimental Ophthalmology & Glaucoma Research, Paracelsus Medical University Salzburg, Austria.

Abstract

Background

Prepectoral implant-based breast reconstruction after nipple-sparing mastectomy or skin-sparing mastectomy has already shown several advantages. Synthetic meshes are often used as a supportive layer to achieve satisfying and stable results. We present our data using Serasynth Mesh BR Pocket, a fully dissolvable, ready-to-use mesh pocket.Methods

Between December 2021 and August 2023, a single-center retrospective study evaluated 53 breast reconstructions (43 patients) for short-term complications. Complications were classified as major (requiring revision surgery) or minor (managed conservatively). All patients underwent nipple-sparing mastectomy or skin-sparing mastectomy followed by direct-to-implant or direct-to-expander reconstruction using Serasynth Mesh BR Pocket. The minimum follow-up was 4 weeks.Results

Of 53 breasts, 44 (83%) required no further surgical intervention, with a mean follow-up of 10 months (range 1-20, mo). Major complications occurred in 9 breasts (17%), and minor complications occurred in 13 (24.5%). Implant loss (13.2%) was primarily due to necrosis (7.5%). A higher body mass index (≥27 kg/m²) and axillary lymph node excision were associated with an increased risk of complications. Notably, 41.9% of patients received adjuvant radiotherapy.Conclusions

Serasynth Mesh BR Pocket demonstrates a favorable safety profile in prepectoral breast reconstruction, even in a high-risk cohort with substantial radiotherapy exposure. Outcomes are comparable to those of other synthetic meshes, with the added benefit of full resorbability. Careful patient selection, considering body mass index, soft-tissue quality, and lymph node dissection, is essential to optimize results.

Related

  1. Long-term implant integrity and complications after risk-reducing mastectomy with immediate implant reconstruction: a retrospective cohort study with prospective ultrasound follow-up at a Swedish university hospital
    Jessica Gahm, Marie Jaeger, Zlatan Alagic +1
    BMJ OpenPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossref
  2. Comparison of surgical outcomes, safety, and cosmetic satisfaction between immediate implant-based and transverse rectus abdominis myocutaneous (TRAM) flap breast reconstruction following total mastectomy: a retrospective cohort study
    Putthiporn Yenbutra, Pimmanee Nitisavat
    Gland SurgeryPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Peri-areolar dermal reinforcement to prevent prosthetic-related complications in prepectoral reconstruction with a compromised nipple-areola complex: a surgical technique
    Joon-Sung Lee, Sang-Oh Lee, Du-Hyong Cho +2
    Gland SurgeryPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Short-term implant survivorship and failure modes of the LPS™ system in distal femoral reconstruction: A multicentre retrospective study
    Victoria L’hourre, Agathe Yvinou, Frederic Dubrana +7
    Orthopaedics & Traumatology: Surgery & ResearchPeer-reviewedCC BYSurgery & anaesthesiaHAL
  5. No superiority of double drains over single drainage after tissue expander–based breast reconstruction: A systematic review and meta-analysis
    Lucas Monteiro Delgado, Enes Agah Kodalak, Guilherme Franceschini Machado +6
    JPRAS openPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
BibTeX
@article{wimmer2026serasynth,
  title = {{Serasynth Mesh BR Pocket in Prepectoral Direct-to-implant and Tissue-expander Breast Reconstruction: A Retrospective Single-center Analysis.}},
  author = {Florian Wimmer and Alexander Panzirsch and Wolfgang Hitzl and Gabriel Djedovic},
  journal = {Plastic and reconstructive surgery. Global open},
  year = {2026},
  month = oct,
  doi = {10.1097/gox.0000000000008178},
  url = {https://europepmc.org/article/MED/42903288},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Serasynth Mesh BR Pocket in Prepectoral Direct-to-implant and Tissue-expander Breast Reconstruction: A Retrospective Single-center Analysis.
AU  - Florian Wimmer
AU  - Alexander Panzirsch
AU  - Wolfgang Hitzl
AU  - Gabriel Djedovic
PY  - 2026
DA  - 2026/10/20
JO  - Plastic and reconstructive surgery. Global open
DO  - 10.1097/gox.0000000000008178
UR  - https://europepmc.org/article/MED/42903288
AB  - Background  Prepectoral implant-based breast reconstruction after nipple-sparing mastectomy or skin-sparing mastectomy has already shown several advantages. Synthetic meshes are often used as a supportive layer to achieve satisfying and stable results. We present our data using Serasynth Mesh BR Pocket, a fully dissolvable, ready-to-use mesh pocket.Methods  Between December 2021 and August 2023, a single-center retrospective study evaluated 53 breast reconstructions (43 patients) for short-term complications. Complications were classified as major (requiring revision surgery) or minor (managed conservatively). All patients underwent nipple-sparing mastectomy or skin-sparing mastectomy followed by direct-to-implant or direct-to-expander reconstruction using Serasynth Mesh BR Pocket. The minimum follow-up was 4 weeks.Results  Of 53 breasts, 44 (83%) required no further surgical intervention, with a mean follow-up of 10 months (range 1-20, mo). Major complications occurred in 9 breasts (17%), and minor complications occurred in 13 (24.5%). Implant loss (13.2%) was primarily due to necrosis (7.5%). A higher body mass index (≥27 kg/m²) and axillary lymph node excision were associated with an increased risk of complications. Notably, 41.9% of patients received adjuvant radiotherapy.Conclusions  Serasynth Mesh BR Pocket demonstrates a favorable safety profile in prepectoral breast reconstruction, even in a high-risk cohort with substantial radiotherapy exposure. Outcomes are comparable to those of other synthetic meshes, with the added benefit of full resorbability. Careful patient selection, considering body mass index, soft-tissue quality, and lymph node dissection, is essential to optimize results.
SN  - 2169-7574
ER  -