Skip to content
DraconiticResearch
Search Sources API
197,785 studies31 sourcesUpdated 9 min ago
PreprintCC BY 4.0arXiv

UPLOAD-HELIX: High-Helicity Single-Mode Microwave Haloscope with Low-Noise Interferometric Readout for Ultralight Axion Dark Matter

Abstract

We propose a superconducting single-mode microwave haloscope based on chiral cavity resonators for the detection of ultralight dark matter axions over the mass range 4×10−19-4×10−14 eV. Building on the single-mode chiral-cavity concept introduced by Bourhill et al. [Phys. Rev. D 108, 052014 (2023); arXiv:2208.01640], we develop a resonator geometry compatible with subtractive manufacturing from high-purity bulk niobium, taking advantage of the substantially lower surface resistance achievable relative to the additively manufactured Möbius cavity proposed in the earlier work. An inverse-design framework is then used to maximise a figure of merit derived to minimise the measurement time required to achieve a fixed experimental sensitivity. The resulting optimised bulk-niobium design achieves a figure of merit more than three orders of magnitude larger than the additively manufactured Mobius benchmark. An experimentally informed microwave interferometric readout model, incorporating measured electronics noise and active suppression of pump amplitude noise, is used to project the sensitivity of the proposed experiment. For an acquisition time of three months, the haloscope is projected to reach gaγγ<10−11 GeV−1 across more than four orders of magnitude in axion mass. The projected sensitivity extends approximately one order of magnitude below the current exclusion limits set by CAST, providing a practical pathway towards a high-sensitivity direct search for ultralight dark matter axions.

Related

  1. Power of Axion Microwave Absorbed by Quantum Hall State in Haloscope
    Aiichi Iwazaki
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  2. Interferometric Readout of Momentum-Space Topology in a Programmable Dissipative Photonic Circuit
    Andrea Cataldo, Emil J. Bergholtz, Daniel Leykam +2
    arXivPreprintCC BY 4.0Full textCondensed matterOptics & photonicsarXiv
  3. Fisher-Information Recovery in Superconducting-Qubit Magnetometry with Squeezed-Microwave Readout
    M. -R. Yun, Y. -J. Qu, Zheng Shan +3
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  4. Photon-Counting Readout via Electro-Optic Microwave-to-Optical Transduction for Axion Haloscopes
    Jing Wu, Raphael Cervantes, Doga Murat Kurkcuoglu +2
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsQuantum physics & quantum informationarXiv
  5. Trapping photo-carriers in undoped gate-defined quantum dots using an on-chip microwave resonator for charge readout
    Pierre Lefloïc, Zhiren Wang, Yasmine Faraj +5
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
BibTeX
@misc{crew2026uploadhelix,
  title = {{UPLOAD-HELIX: High-Helicity Single-Mode Microwave Haloscope with Low-Noise Interferometric Readout for Ultralight Axion Dark Matter}},
  author = {Robert C. Crew and Emma C. I. Paterson and Maxim Goryachev and Eugene N. Ivanov and Pashupati Dhakal and Tugrul Talha Ersoz and Michael E. Tobar and Jeremy F. Bourhill},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2608.19225},
  eprint = {2608.19225},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2608.19225},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - UPLOAD-HELIX: High-Helicity Single-Mode Microwave Haloscope with Low-Noise Interferometric Readout for Ultralight Axion Dark Matter
AU  - Robert C. Crew
AU  - Emma C. I. Paterson
AU  - Maxim Goryachev
AU  - Eugene N. Ivanov
AU  - Pashupati Dhakal
AU  - Tugrul Talha Ersoz
AU  - Michael E. Tobar
AU  - Jeremy F. Bourhill
PY  - 2026
DA  - 2026/09/10
PB  - arXiv
DO  - 10.48550/arxiv.2608.19225
UR  - https://arxiv.org/abs/2608.19225
AB  - We propose a superconducting single-mode microwave haloscope based on chiral cavity resonators for the detection of ultralight dark matter axions over the mass range 4×10^−19-4×10^−14 eV. Building on the single-mode chiral-cavity concept introduced by Bourhill et al. [Phys. Rev. D 108, 052014 (2023); arXiv:2208.01640], we develop a resonator geometry compatible with subtractive manufacturing from high-purity bulk niobium, taking advantage of the substantially lower surface resistance achievable relative to the additively manufactured Möbius cavity proposed in the earlier work. An inverse-design framework is then used to maximise a figure of merit derived to minimise the measurement time required to achieve a fixed experimental sensitivity. The resulting optimised bulk-niobium design achieves a figure of merit more than three orders of magnitude larger than the additively manufactured Mobius benchmark. An experimentally informed microwave interferometric readout model, incorporating measured electronics noise and active suppression of pump amplitude noise, is used to project the sensitivity of the proposed experiment. For an acquisition time of three months, the haloscope is projected to reach g_aγγ<10^−11 GeV^−1 across more than four orders of magnitude in axion mass. The projected sensitivity extends approximately one order of magnitude below the current exclusion limits set by CAST, providing a practical pathway towards a high-sensitivity direct search for ultralight dark matter axions.
ER  -