Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 3 min ago
Peer-reviewedCC BY-NC-NDBMC gastroenterology

An explainable multimodal model integrating post-ESD mucosal defect images and clinical features to predict delayed bleeding after colorectal endoscopic submucosal dissection.

6 affiliations
  1. 1Department of Gastroenterology, Changshu No. 1 People's Hospital (Changshu Hospital, Soochow University), Suzhou, 215500, China.
  2. 2Department of Gastroenterology, Changshu Traditional Chinese Medicine Hospital (Changshu Hospital, Nanjing University of Chinese Medicine), Suzhou, 215500, China.
  3. 3Changshu Key Laboratory of Medical Artificial Intelligence and Big Data, Suzhou, 215500, China.
  4. 4Department of Gastroenterology, The Second Qilu Hospital of Shandong University, Jinan, 250033, Shandong, China. [email protected].
  5. 5Department of Gastroenterology, Changshu No. 1 People's Hospital (Changshu Hospital, Soochow University), Suzhou, 215500, China. [email protected].
  6. 6Changshu Key Laboratory of Medical Artificial Intelligence and Big Data, Suzhou, 215500, China. [email protected].

Abstract

Background

Existing tools for predicting delayed bleeding (DB) after colorectal endoscopic submucosal dissection (ESD) use only structured clinical variables, leaving information in post-ESD mucosal defect images unused. We developed and externally validated an explainable multimodal model integrating these images with clinical features.Methods

We retrospectively included 3,416 patients who underwent colorectal ESD at two hospitals from January 2022 through June 2026 (development cohort, n = 2,778; external validation cohort, n = 638). DB was active bleeding 6 h to 28 days after ESD, confirmed by repeat endoscopy and requiring endoscopic hemostasis. YOLOv11m-seg segmented mucosal defects, ResNet50 generated an image-derived prediction score (E-Score), and the E-Score was fused with clinical features. After LASSO feature selection, five algorithms with and without SMOTE were evaluated by fivefold stratified cross-validation. SHAP and Grad-CAM provided post-hoc feature- and image-level explanations.Results

DB occurred in 224 patients (8.06%) in the development cohort and 53 (8.31%) in the external validation cohort (P = 0.839). The segmentation model achieved mAP50 and mAP50-95 values of 0.984 and 0.838. Six features were retained. XGBoost without SMOTE (PrismDB) performed best (area under the receiver operating characteristic curve [AUC], 0.804; 95% confidence interval [CI], 0.769-0.837), with 64.73% sensitivity, 85.40% specificity, and 96.50% negative predictive value. In external validation, the AUC was 0.788 (95% CI, 0.724-0.850), sensitivity was 79.25%, specificity was 83.25%, and negative predictive value was 97.79%. Probability calibration in the development cohort under the natural event distribution showed a calibration slope of 1.101 and an intercept of + 0.227 (Brier score, 0.0584). E-Score had the highest mean absolute SHAP contribution, and representative activation maps overlapped with exposed vessels, adherent clots, and eschar.Conclusions

PrismDB showed stable discrimination for DB after colorectal ESD. Low-risk classification did not exclude DB. Probability calibration was acceptable in the development cohort but has not been evaluated externally, and the safety of model-guided changes to postoperative care remains to be established; the companion web application demonstrates the prediction workflow.

Related

  1. Smart colorectal endoscopic submucosal dissection: integrating traction, pocket creation and underwater dissection to enhance efficiency
    Pier-Anne Gaulin, Paul Carrier, Sophie Geyl +4
    EndoscopyPeer-reviewedCC BYOncologyHAL
  2. Safe colorectal endoscopic submucosal dissection for diverticulum involving lesions via modern combined strategies
    Augustin Carton, Pier-Anne Gaulin, Stefano Andrea Marchitto +4
    EndoscopyPeer-reviewedCC BYOncologyHAL
  3. Safety and efficacy of extended surveillance intervals following colorectal endoscopic submucosal dissection: an international multicentre study
    Abdulrahman Qatomah, Paul Brouzeng, Daryl Ramai +10
    GutPeer-reviewedLicence not statedFull text1 citedOncologyHAL
  4. Hybrid underwater endoscopic submucosal dissection : a safe and efficient training strategy for colorectal endoscopic submucosal dissection trainees
    Pier-Anne Gaulin, Remi Collin, Paul Carrier +4
    EndoscopyPeer-reviewedCC BYFull text1 citedSurgery & anaesthesiaHAL
  5. Prediction Models for Delayed Bleeding After Colorectal Endoscopic Submucosal Dissection: A Systematic Review and Critical Appraisal.
    Da Miao, Zhuoer Hou, Yao Ge +1
    DEN openPeer-reviewedCC BYFull textOncologyEurope PMC
BibTeX
@article{zhao2026explainable,
  title = {{An explainable multimodal model integrating post-ESD mucosal defect images and clinical features to predict delayed bleeding after colorectal endoscopic submucosal dissection.}},
  author = {Hang Zhao and Xiaodan Xu and Ganhong Wang and Kaijian Xia and Teng Wang and Jian Chen},
  journal = {BMC gastroenterology},
  year = {2026},
  month = nov,
  doi = {10.1186/s12876-026-05418-9},
  url = {https://europepmc.org/article/MED/43009812},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - An explainable multimodal model integrating post-ESD mucosal defect images and clinical features to predict delayed bleeding after colorectal endoscopic submucosal dissection.
AU  - Hang Zhao
AU  - Xiaodan Xu
AU  - Ganhong Wang
AU  - Kaijian Xia
AU  - Teng Wang
AU  - Jian Chen
PY  - 2026
DA  - 2026/11/10
JO  - BMC gastroenterology
DO  - 10.1186/s12876-026-05418-9
UR  - https://europepmc.org/article/MED/43009812
AB  - Background  Existing tools for predicting delayed bleeding (DB) after colorectal endoscopic submucosal dissection (ESD) use only structured clinical variables, leaving information in post-ESD mucosal defect images unused. We developed and externally validated an explainable multimodal model integrating these images with clinical features.Methods  We retrospectively included 3,416 patients who underwent colorectal ESD at two hospitals from January 2022 through June 2026 (development cohort, n = 2,778; external validation cohort, n = 638). DB was active bleeding 6 h to 28 days after ESD, confirmed by repeat endoscopy and requiring endoscopic hemostasis. YOLOv11m-seg segmented mucosal defects, ResNet50 generated an image-derived prediction score (E-Score), and the E-Score was fused with clinical features. After LASSO feature selection, five algorithms with and without SMOTE were evaluated by fivefold stratified cross-validation. SHAP and Grad-CAM provided post-hoc feature- and image-level explanations.Results  DB occurred in 224 patients (8.06%) in the development cohort and 53 (8.31%) in the external validation cohort (P = 0.839). The segmentation model achieved mAP50 and mAP50-95 values of 0.984 and 0.838. Six features were retained. XGBoost without SMOTE (PrismDB) performed best (area under the receiver operating characteristic curve [AUC], 0.804; 95% confidence interval [CI], 0.769-0.837), with 64.73% sensitivity, 85.40% specificity, and 96.50% negative predictive value. In external validation, the AUC was 0.788 (95% CI, 0.724-0.850), sensitivity was 79.25%, specificity was 83.25%, and negative predictive value was 97.79%. Probability calibration in the development cohort under the natural event distribution showed a calibration slope of 1.101 and an intercept of + 0.227 (Brier score, 0.0584). E-Score had the highest mean absolute SHAP contribution, and representative activation maps overlapped with exposed vessels, adherent clots, and eschar.Conclusions  PrismDB showed stable discrimination for DB after colorectal ESD. Low-risk classification did not exclude DB. Probability calibration was acceptable in the development cohort but has not been evaluated externally, and the safety of model-guided changes to postoperative care remains to be established; the companion web application demonstrates the prediction workflow.
SN  - 1471-230X
ER  -