Skip to content
DraconiticResearch
Search Sources API
182,544 studies31 sourcesUpdated 27 min ago
Peer-reviewedCC BY-NC-NDBMC anesthesiology

Comparison of bedside clinical pupillary assessment with automated pupillometry in sedated ICU patients.

7 affiliations
  1. 1Service d'anesthésie-réanimation et médecine péri-opératoire, Hôpital Maison Blanche, CHU de Reims, Reims, F-51000, France.
  2. 2Service d'Ophtalmologie, CHU de Reims, Reims, F-51000, France.
  3. 3Département de recherche et de santé publique, CHU de Reims, Reims, F-51000, France.
  4. 4Université de Reims Champagne-Ardenne, VieFra, Reims, F-51100, France.
  5. 5Service d'anesthésie-réanimation et médecine péri-opératoire, Hôpital Maison Blanche, CHU de Reims, Reims, F-51000, France. [email protected].
  6. 6Université de Reims Champagne-Ardenne, VieFra, Reims, F-51100, France. [email protected].
  7. 7Critical Care and Perioperative Medicine, Hôpital Maison Blanche, CHU de Reims, 45 Rue Cognacq Jay, Reims, 51092, France. [email protected].

Abstract

Background

Pupillary assessment is central in neurocritical care and although inherently subjective, bedside penlight examination remains standard practice. While automated pupillometry provides objective, standardized measurements, the reliability of manual assessment across professional categories remains poorly characterized.Methods

Prospective observational study in a surgical and trauma intensive care unit (Reims, Feb-Dec 2025). Thirty sedated or comatose adults underwent repeated pupillary assessments by nurses, residents, and senior physicians, which were compared with automated pupillometry as the reference standard, yielding 1,692 paired bilateral measurements from 30 patients. Primary outcome was agreement for anisocoria detection (≥ 1 mm) and secondary outcomes were pupil size and reactivity, measured using Brennan-Prediger adjusted kappa and McNemar test.Results

Agreement for anisocoria was substantial: nurses κ = 0.64 (95% CI 0.57-0.72), residents κ = 0.74 (0.68-0.81), physicians κ = 0.71 (0.64-0.78 ,p < 0.0001). False-positive rates were high (82-86%), while true anisocoria was detected in 55-73% of cases. For pupil size, agreement was substantial: nurses κ = 0.65 (0.60-0.70), residents κ = 0.64 (0.59-0.65), physicians κ = 0.66 (0.60-0.71), but mydriasis was largely missed (6-11% detection; p < 0.0001). Reactivity showed the weakest agreement: nurses κ = 0.40 (0.34-0.47), residents κ = 0.32 (0.26-0.39), physicians κ = 0.41 (0.34-0.47), with systemic underestimation in nurses (p ≤ 0.0001) and a bidirectional error pattern for residents (p = 0.81).Conclusion

In sedated ICU patients, bedside pupillary assessment showed substantial but systematically biased agreement with automated pupillometry, particularly for anisocoria, mydriasis, and pupillary reactivity. These findings highlight the limitations of subjective bedside assessment and support automated pupillometry as an objective complement to routine clinical examination.Trial registration

NCT06733207, registered 10 December 2024 - Retrospectively registered, https://clinicaltrials.gov/study/NCT06733207.

Related

  1. Comparison of two automated pupillometry indices in patients with acute brain injury: the prospective multicentre LYNX cohort study.
    Pierre Bouzat, Aaron Blandino-Ortiz, Antoine Vilotitch +6
    Critical care (London, England)Peer-reviewedCC BY-NC-NDFull text2 citedNeurologyEurope PMC
  2. Comparison of two automated PGMI-based software tools for breast positioning quality assessment in DBT screening
    Gisella Gennaro, Stefano Trazzi, Valentina Bordon +1
    European radiology experimentalPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  3. PO034 | ASSESSMENT OF PLATELET AGGREGATION FOR THE DIAGNOSIS OF INHERITED PLATELET DISORDERS USING A FULLY AUTOMATED COAGULATION ANALYSER: COMPARISON WITH LTA AND MEA
    Emanuela Falcinelli
    Bleeding, Thrombosis and Vascular BiologyPeer-reviewedCC BY-NCFull textCardiovascular medicineDOAJ
  4. Stability study of 17 clinical immunoassays analytes in serum and plasma samples within an automated storage and retrieval module: Assessment of add-on testing policies
    Mohammed Bouriche, Cyril Leven, Hélène Kerspern +2
    Clinical BiochemistryPeer-reviewedCC BY 4.0Full text1 citedPhysiologyHAL
  5. Comparison of Clinical and Ultrasonographic Severity Assessment in Hidradenitis Suppurativa: Prognostic Implications.
    Juncheng Wang, Jing Qin, Xiao Ma +3
    Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)Peer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMCPMC
BibTeX
@article{arndt2026comparison,
  title = {{Comparison of bedside clinical pupillary assessment with automated pupillometry in sedated ICU patients.}},
  author = {Alice Arndt and Pierre-Antoine Seube-Remy and Thierry Floch and Carl Arndt and Lukshe Kanagaratnam and Vincent Legros},
  journal = {BMC anesthesiology},
  year = {2026},
  month = jul,
  doi = {10.1186/s12871-026-04124-z},
  url = {https://europepmc.org/article/MED/42968011},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Comparison of bedside clinical pupillary assessment with automated pupillometry in sedated ICU patients.
AU  - Alice Arndt
AU  - Pierre-Antoine Seube-Remy
AU  - Thierry Floch
AU  - Carl Arndt
AU  - Lukshe Kanagaratnam
AU  - Vincent Legros
PY  - 2026
DA  - 2026/07/28
JO  - BMC anesthesiology
DO  - 10.1186/s12871-026-04124-z
UR  - https://europepmc.org/article/MED/42968011
AB  - Background  Pupillary assessment is central in neurocritical care and although inherently subjective, bedside penlight examination remains standard practice. While automated pupillometry provides objective, standardized measurements, the reliability of manual assessment across professional categories remains poorly characterized.Methods  Prospective observational study in a surgical and trauma intensive care unit (Reims, Feb-Dec 2025). Thirty sedated or comatose adults underwent repeated pupillary assessments by nurses, residents, and senior physicians, which were compared with automated pupillometry as the reference standard, yielding 1,692 paired bilateral measurements from 30 patients. Primary outcome was agreement for anisocoria detection (≥ 1 mm) and secondary outcomes were pupil size and reactivity, measured using Brennan-Prediger adjusted kappa and McNemar test.Results  Agreement for anisocoria was substantial: nurses κ = 0.64 (95% CI 0.57-0.72), residents κ = 0.74 (0.68-0.81), physicians κ = 0.71 (0.64-0.78 ,p < 0.0001). False-positive rates were high (82-86%), while true anisocoria was detected in 55-73% of cases. For pupil size, agreement was substantial: nurses κ = 0.65 (0.60-0.70), residents κ = 0.64 (0.59-0.65), physicians κ = 0.66 (0.60-0.71), but mydriasis was largely missed (6-11% detection; p < 0.0001). Reactivity showed the weakest agreement: nurses κ = 0.40 (0.34-0.47), residents κ = 0.32 (0.26-0.39), physicians κ = 0.41 (0.34-0.47), with systemic underestimation in nurses (p ≤ 0.0001) and a bidirectional error pattern for residents (p = 0.81).Conclusion  In sedated ICU patients, bedside pupillary assessment showed substantial but systematically biased agreement with automated pupillometry, particularly for anisocoria, mydriasis, and pupillary reactivity. These findings highlight the limitations of subjective bedside assessment and support automated pupillometry as an objective complement to routine clinical examination.Trial registration  NCT06733207, registered 10 December 2024 - Retrospectively registered, https://clinicaltrials.gov/study/NCT06733207.
SN  - 1471-2253
ER  -