Inside the battery box: a cross-technology assessment of PFAS uses, functions, and substitution potential
8 affiliations
- 1Department of Environmental Science, Stockholm University SE-10691 Stockholm Sweden
- 2Institute for Biogeochemistry and Pollutant Dynamics, ETH Zurich 8092 Zurich Switzerland
- 3Department of Green Technology, Danish Institute for Advanced Study (DIAS), University of Southern Denmark 5230 Odense Denmark
- 4Empa – Swiss Federal Laboratories for Materials Science and Technology, Technology and Society Laboratory 9014 St. Gallen Switzerland
- 5NCCR Catalysis, ETH Zürich 8093 Zürich Switzerland
- 6Graduate School of Oceanography, University of Rhode Island Narragansett RI 02882 USA
- 7Department of Civil & Environmental Engineering and Environmental and Occupational Health, University of Pittsburgh Pittsburgh 15261 Pennsylvania USA
- 8Department of Plant and Environmental Sciences, Section for Environmental Chemistry and Physics, University of Copenhagen Thorvaldsensvej 40 DK-1871 Frederiksberg C Denmark
Abstract
Understanding where and why per- and polyfluoroalkyl substances (PFASs) are used in batteries is essential for evaluating their substitution potential, yet detailed information across battery technologies is scarce. We analyzed more than 5600 submissions to the Annex XV public consultation on the proposed universal PFAS restriction in the European Union and extracted information reporting use, associated substance(s), and stated function(s) of PFASs in batteries. 341 records were compiled into a database using our structured Battery Use & Function Framework that incorporates the Functional Substitution Framework. Among these records, 78 contained sufficient information to qualify as a potential PFAS use and were organized into 36 potential PFAS uses, accounting for overlaps. Each potential PFAS use was evaluated using supporting evidence from previous use-mapping studies, input from battery stakeholders, teardown-analysis studies, and other targeted academic literature. Across all lines of evidence, two PFAS uses in batteries were contradicted, indicating already large-scale availability of PFAS-free alternatives, while 16 PFAS uses were confirmed, primarily in cathode components across several battery technologies and chemistries. PFAS-free alternatives were identified for 13 PFAS uses across battery applications, with an additional five uses showing PFAS-free options for certain applications within the broader use category. The findings indicate that few technical barriers remain for substituting PFASs in most battery components. Our mapping provides a detailed foundation for future alternatives assessments, supports essential-use evaluations, and highlights opportunities and challenges relevant to monitoring and recycling.
Related
- Life Cycle Carbon Footprint Assessment of Battery Energy Storage Systems: A Review
- Forecasting end-of-life electric vehicle batteries in Palestine: Circularity readiness assessment, scenario analysis, and policy roadmap for sustainable battery management
- Thermo-Hydraulic Performance Assessment of Al2O3–Mineral Oil Nanofluids for Direct Immersion Cooling of Lithium-Ion Battery Packs Under Fast-Charging
- Cascading Valorisation of Agri-Food Waste in Circular Biorefineries: A Critical Review of Technology Integration, Life Cycle Assessment and AI-Assisted Decision Support
- Mycogenic synthesis of copper oxide nanoparticles using response surface methodology and assessment of their biological potential
BibTeX
@article{rensmo2026inside,
title = {{Inside the battery box: a cross-technology assessment of PFAS uses, functions, and substitution potential}},
author = {Amanda Rensmo and Anna J. Miller and Juliane Glüge and Martin Scheringer and Zhanyun Wang and Rainer Lohmann and Carla A. Ng and Xenia Trier and Ian T. Cousins},
journal = {Environmental Science. Processes \& Impacts},
year = {2026},
month = nov,
doi = {10.1039/d6em00349d},
url = {https://doi.org/10.1039/d6em00349d},
note = {CC BY 3.0},
}
RIS
TY - JOUR
TI - Inside the battery box: a cross-technology assessment of PFAS uses, functions, and substitution potential
AU - Amanda Rensmo
AU - Anna J. Miller
AU - Juliane Glüge
AU - Martin Scheringer
AU - Zhanyun Wang
AU - Rainer Lohmann
AU - Carla A. Ng
AU - Xenia Trier
AU - Ian T. Cousins
PY - 2026
DA - 2026/11/12
JO - Environmental Science. Processes & Impacts
DO - 10.1039/d6em00349d
UR - https://doi.org/10.1039/d6em00349d
AB - Understanding where and why per- and polyfluoroalkyl substances (PFASs) are used in batteries is essential for evaluating their substitution potential, yet detailed information across battery technologies is scarce. We analyzed more than 5600 submissions to the Annex XV public consultation on the proposed universal PFAS restriction in the European Union and extracted information reporting use, associated substance(s), and stated function(s) of PFASs in batteries. 341 records were compiled into a database using our structured Battery Use & Function Framework that incorporates the Functional Substitution Framework. Among these records, 78 contained sufficient information to qualify as a potential PFAS use and were organized into 36 potential PFAS uses, accounting for overlaps. Each potential PFAS use was evaluated using supporting evidence from previous use-mapping studies, input from battery stakeholders, teardown-analysis studies, and other targeted academic literature. Across all lines of evidence, two PFAS uses in batteries were contradicted, indicating already large-scale availability of PFAS-free alternatives, while 16 PFAS uses were confirmed, primarily in cathode components across several battery technologies and chemistries. PFAS-free alternatives were identified for 13 PFAS uses across battery applications, with an additional five uses showing PFAS-free options for certain applications within the broader use category. The findings indicate that few technical barriers remain for substituting PFASs in most battery components. Our mapping provides a detailed foundation for future alternatives assessments, supports essential-use evaluations, and highlights opportunities and challenges relevant to monitoring and recycling.
SN - 2050-7887
SN - 2050-7895
ER -