Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 16 min ago
Peer-reviewedCC BYBiosensors

Monitoring Reduced Vigilance Using an Eyeglass-Type EEG System.

5 affiliations
  1. 1Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.
  2. 2School of Biomedical Convergence Engineering, Pusan National University, Yangsan 50612, Republic of Korea.
  3. 3School of Electrical Engineering, Kookmin University, Seoul 02707, Republic of Korea.
  4. 4Department of Neurology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul 03080, Republic of Korea.
  5. 5Department of Biomedical Engineering, Hanyang University, Seoul 04763, Republic of Korea.

Abstract

An eyeglass-type electroencephalography (EEG) device has emerged as a promising platform for continuous cognitive state monitoring owing to its seamless integration into daily life and greater usability compared with conventional headset-style EEG systems. However, the feasibility of EEG-based reduced-vigilance monitoring using this form factor remains insufficiently examined. To address this issue, we conducted a two-phase experiment involving 21 participants to establish a mental fatigue-sensitive index and validate a monitoring algorithm for reduced vigilance associated with drowsiness or mental fatigue using a custom-made eyeglass-type EEG device. In the first phase, a long-term sustained attention task (d2 test) was employed to induce mental fatigue, and the ratio of low-alpha to high-beta power was identified as a potential biomarker of mental-fatigue-related vigilance decline. In the second phase, system performance was evaluated through a prolonged, monotonous video-watching experiment designed to elicit reduced vigilance. The algorithm combined the drowsiness detection index (theta-plus-alpha power) from the TP9 and TP10 channels with the candidate fatigue-sensitive index from the differential channel. Subject-specific calibration-based thresholds were used to generate index-specific segment-level decisions, which were combined using a logical OR rule. In the pseudo-real-time evaluation of 16 participants, the final fusion model achieved a mean accuracy of 70.31%, a false-positive rate of 10.40%, a recall of 49.67%, and a precision of 81.80%, calculated from participant-level metrics. Detection performance depended partly on the inclusion of segments with prolonged eye closure, with lower recall after their exclusion. Nevertheless, these findings provide preliminary evidence for the feasibility of detecting behaviorally defined reduced vigilance using an eyeglass-type EEG device.

Related

  1. Defining a Clinically Meaningful Within-Person Change Threshold for the Psychomotor Vigilance Test in Narcolepsy Type 1
    Brian T. Harel, Robert H. Pietrzak, Shruti Dave +4
    Therapeutic Innovation & Regulatory SciencePeer-reviewedCC BY 4.0Full textNeurosciencePMC
  2. Life finds its way in seaports: environmental DNA monitoring in the Grand Port Maritime de Guadeloupe shows vertebrate richness but reduced phylogenetic diversity
    Rachel Haderlé, Karen Cosnier, Samuel Iglésias +3
    Royal Society Open SciencePeer-reviewedCC BY1 citedEcologyHAL
  3. Troisièmes rencontres d’allergo-vigilance – Paris 5/12/2025
    X. van der Brempt, F. Bérard, C. Tacquard +13
    Revue Française d'AllergologiePeer-reviewedLicence not statedImmunologyHAL
  4. Bardet-Biedl Syndrome Type 10 Mice Display Reduced Anxiety-like Behavior.
    Mackenzie Bengen, Ying Hsu, Naim Chabaytah +6
    MicroPublication biologyPeer-reviewedCC BYFull textGenetics & genomicsEurope PMCPMC
  5. Soil parameters associated with Fusarium oxysporum f. sp. cubense incidence and their integration into an IoT-based monitoring system for banana plantations
    Bonaventure Uwamahoro, Martin Kuradusenge, Abubakar Diwani Bakari +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textPlant biologyCrossref
BibTeX
@article{lee2026monitoring,
  title = {{Monitoring Reduced Vigilance Using an Eyeglass-Type EEG System.}},
  author = {Kyeonggu Lee and Hyeji Yu and Minsu Kim and Hongjin Kim and Seohyeon Kim and Jonggyun Kim and Ki-Young Jung and Seung Min Lee and Chang-Hwan Im},
  journal = {Biosensors},
  year = {2026},
  month = nov,
  doi = {10.3390/bios16110641},
  url = {https://europepmc.org/article/MED/43082536},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Monitoring Reduced Vigilance Using an Eyeglass-Type EEG System.
AU  - Kyeonggu Lee
AU  - Hyeji Yu
AU  - Minsu Kim
AU  - Hongjin Kim
AU  - Seohyeon Kim
AU  - Jonggyun Kim
AU  - Ki-Young Jung
AU  - Seung Min Lee
AU  - Chang-Hwan Im
PY  - 2026
DA  - 2026/11/09
JO  - Biosensors
DO  - 10.3390/bios16110641
UR  - https://europepmc.org/article/MED/43082536
AB  - An eyeglass-type electroencephalography (EEG) device has emerged as a promising platform for continuous cognitive state monitoring owing to its seamless integration into daily life and greater usability compared with conventional headset-style EEG systems. However, the feasibility of EEG-based reduced-vigilance monitoring using this form factor remains insufficiently examined. To address this issue, we conducted a two-phase experiment involving 21 participants to establish a mental fatigue-sensitive index and validate a monitoring algorithm for reduced vigilance associated with drowsiness or mental fatigue using a custom-made eyeglass-type EEG device. In the first phase, a long-term sustained attention task (d2 test) was employed to induce mental fatigue, and the ratio of low-alpha to high-beta power was identified as a potential biomarker of mental-fatigue-related vigilance decline. In the second phase, system performance was evaluated through a prolonged, monotonous video-watching experiment designed to elicit reduced vigilance. The algorithm combined the drowsiness detection index (theta-plus-alpha power) from the TP9 and TP10 channels with the candidate fatigue-sensitive index from the differential channel. Subject-specific calibration-based thresholds were used to generate index-specific segment-level decisions, which were combined using a logical OR rule. In the pseudo-real-time evaluation of 16 participants, the final fusion model achieved a mean accuracy of 70.31%, a false-positive rate of 10.40%, a recall of 49.67%, and a precision of 81.80%, calculated from participant-level metrics. Detection performance depended partly on the inclusion of segments with prolonged eye closure, with lower recall after their exclusion. Nevertheless, these findings provide preliminary evidence for the feasibility of detecting behaviorally defined reduced vigilance using an eyeglass-type EEG device.
SN  - 2079-6374
ER  -