Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 53 min ago
Peer-reviewedCC BY 4.0Journal of Clinical Microbiology

Optimization of culture read times using full microbiology laboratory automation

  1. 1Department of Pathology, Microbiology, and Immunology, Vanderbilt University Medical Center, Nashville, Tennessee, USA

Abstract

Clinical microbiology laboratories are increasingly adopting automation to meet testing demands, improve throughput, and accelerate diagnostic turnaround. This study evaluated optimal culture read times using Copan WaspLab microbiology laboratory automation (MLA) to determine if earlier read times affect accuracy and turnaround times as they pertain to microbial identification and antimicrobial susceptibility testing (AST). A total of 374 patient specimens were cultured simultaneously using a conventional incubation method and MLA, with MLA images captured from 10 to 72 h of incubation. Non-urine specimens were ready for workup in over 50% of cases at 16 h, 92% by 24 h, and 100% by 36 h, while 90% of urine cultures were ready for workup by 16 h. Using frozen isolates (127 gram-positive bacteria, 83 gram-negative bacteria, and 12 yeasts), we further evaluated the accuracy of MALDI-TOF identification and AST results for cultures incubated for 10 h and 16 h in MLA. Identification accuracy remained high across all groups, with gram-negative bacteria achieving 98.8% accuracy at 10 h and 97.6% at 16 h, gram-positive bacteria showing 97.6% accuracy at 10 h and 98.4% at 16 h, and yeasts demonstrating 91.6% accuracy at 10 h and 100% at 16 h of incubation, respectively. AST results using cultures at both time points demonstrated essential agreement above 90% for most drugs on Vitek 2 GN-807N, GP75, and ST02 AST cards. Minor and major errors were rare; however, elevated error rates were observed for specific drugs (e.g., cefazolin, piperacillin/tazobactam, nitrofurantoin, and linezolid), largely due to a limited number of susceptible isolates and breakpoint-related challenges. MLA enables earlier culture reads while maintaining ID and AST accuracy.

IMPORTANCE: Microbiology laboratory automation (MLA) is increasingly used to address rising test volumes and workforce limitations; however, optimal incubation durations for automated workflows are not well defined. In this study, we demonstrate that cultures from a range of specimen types can be reliably read as early as 16 h and finalized by 36 h without compromising organism identification or antimicrobial susceptibility testing accuracy compared to conventional incubation. These findings support the use of earlier culture read time points in MLA workflows, enabling faster turnaround of clinically actionable results. Implementation of optimized incubation times has the potential to improve laboratory efficiency and accelerate patient care decisions while maintaining diagnostic reliability.

Related

  1. Automation and artificial intelligence in the clinical microbiology laboratory
    Yaodong Wang, Yongxia Zhang, Na Li +1
    Frontiers in cellular and infection microbiologyPeer-reviewedCC BYFull textInfectious diseaseEurope PMCPMC
  2. Design, implementation, and evaluation of a comprehensive educational program for microbiology laboratory personnel and graduate students in teaching hospitals
    Zohre Baseri, Gholamreza Irajian, Amin Dehghan
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEpidemiology & public healthCrossref
  3. Optimization of culture conditions for the human corneal epithelial cell line IM-HCEpiC and evaluation of its extracellular vesicles in repair
    Sara Galindo, Estefanía González-Martín, Helen Gutiérrez +2
    Scientific ReportsPeer-reviewedCC BYFull textMedical imaging & radiologyDOAJ
  4. Standardization of the Monocyte Monolayer Assay: Lessons Learned From Laboratory Optimization and Literature Review.
    Shamee Shastry, Kavya Babu, Deepika Chenna +2
    Journal of clinical laboratory analysisPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Causal effects between gut microbiology and hyperlipidemia : A 2-sample Mendelian randomization study
    Changpeng Du, Yingru Chen, Yan Cheng +2
    MedicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
BibTeX
@article{glover2026optimization,
  title = {{Optimization of culture read times using full microbiology laboratory automation}},
  author = {Janiece S. Glover and Bailey B. Demarest and Pam J. Foster and Kendall A. Bryant},
  journal = {Journal of Clinical Microbiology},
  year = {2026},
  month = sep,
  doi = {10.1128/jcm.00232-26},
  url = {https://doi.org/10.1128/jcm.00232-26},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Optimization of culture read times using full microbiology laboratory automation
AU  - Janiece S. Glover
AU  - Bailey B. Demarest
AU  - Pam J. Foster
AU  - Kendall A. Bryant
PY  - 2026
DA  - 2026/09/18
JO  - Journal of Clinical Microbiology
DO  - 10.1128/jcm.00232-26
UR  - https://doi.org/10.1128/jcm.00232-26
AB  - Clinical microbiology laboratories are increasingly adopting automation to meet testing demands, improve throughput, and accelerate diagnostic turnaround. This study evaluated optimal culture read times using Copan WaspLab microbiology laboratory automation (MLA) to determine if earlier read times affect accuracy and turnaround times as they pertain to microbial identification and antimicrobial susceptibility testing (AST). A total of 374 patient specimens were cultured simultaneously using a conventional incubation method and MLA, with MLA images captured from 10 to 72 h of incubation. Non-urine specimens were ready for workup in over 50% of cases at 16 h, 92% by 24 h, and 100% by 36 h, while 90% of urine cultures were ready for workup by 16 h. Using frozen isolates (127 gram-positive bacteria, 83 gram-negative bacteria, and 12 yeasts), we further evaluated the accuracy of MALDI-TOF identification and AST results for cultures incubated for 10 h and 16 h in MLA. Identification accuracy remained high across all groups, with gram-negative bacteria achieving 98.8% accuracy at 10 h and 97.6% at 16 h, gram-positive bacteria showing 97.6% accuracy at 10 h and 98.4% at 16 h, and yeasts demonstrating 91.6% accuracy at 10 h and 100% at 16 h of incubation, respectively. AST results using cultures at both time points demonstrated essential agreement above 90% for most drugs on Vitek 2 GN-807N, GP75, and ST02 AST cards. Minor and major errors were rare; however, elevated error rates were observed for specific drugs (e.g., cefazolin, piperacillin/tazobactam, nitrofurantoin, and linezolid), largely due to a limited number of susceptible isolates and breakpoint-related challenges. MLA enables earlier culture reads while maintaining ID and AST accuracy.  IMPORTANCE: Microbiology laboratory automation (MLA) is increasingly used to address rising test volumes and workforce limitations; however, optimal incubation durations for automated workflows are not well defined. In this study, we demonstrate that cultures from a range of specimen types can be reliably read as early as 16 h and finalized by 36 h without compromising organism identification or antimicrobial susceptibility testing accuracy compared to conventional incubation. These findings support the use of earlier culture read time points in MLA workflows, enabling faster turnaround of clinically actionable results. Implementation of optimized incubation times has the potential to improve laboratory efficiency and accelerate patient care decisions while maintaining diagnostic reliability.
SN  - 0095-1137
SN  - 1098-660X
ER  -