Optimizing IMPULSED Acquisition Protocols for Clinical 3T Scanners Through Bayesian Experimental Design

  1. 1Department of Radiation Oncology University of Texas Southwestern Medical Center Dallas Texas USA
  2. 2Department of Radiation Oncology and Molecular Radiation Sciences Johns Hopkins University Baltimore Maryland USA

Abstract

Purpose: To optimize diffusion MRI acquisition protocols for Imaging Microstructural Parameters Using Limited Spectrally Edited Diffusion (IMPULSED) model at clinical 3T scanner using Bayesian experimental design, enabling accurate cellular‐scale parameter estimation under realistic scan time and scanner hardware constraints.

Methods: Expected Information Gain (EIG) was used as the optimization objective to maximize the information content of acquired measurements for IMPULSED model fitting. Bayesian optimization with Gaussian process surrogates efficiently searched the high‐dimensional acquisition parameter space, including pulse types (PGSE, OGSEn1, and OGSEn2), diffusion times, and b values. Optimized protocols were systematically evaluated against a heuristically designed baseline protocol through simulation studies assessing classification accuracy and parameter estimation performance across SNR levels of 5–40. Robustness to optimization assumptions was examined by varying prior distributions and assumed SNR. In vivo validation was performed using canine tumor data acquired at 3T.

Results: The optimized protocol eliminated OGSEn2 acquisitions, concentrated measurements at high b values (maximum 2000 s/mm2 for PGSE, 1220 s/mm2 for OGSEn1), employing concurrently optimized diffusion timing. Compared to the baseline protocol, the optimized design achieved superior classification accuracy for distinguishing cell populations and reduced parameter estimation error across biologically relevant parameter ranges at various SNRs. Performance advantages were consistent across diverse optimization scenarios, demonstrating robustness to prior knowledge and noise assumptions. In vivo parameter maps showed substantially improved quality and smoothness.

Conclusion: Bayesian optimization substantially improves IMPULSED acquisition design for clinical 3T scanners. This principled, algorithm‐agnostic framework enables accurate diffusion MRI cytometry under clinical constraints, with potential applications to tumor characterization and treatment monitoring.

Related

  1. Optimizing home blood pressure monitoring protocols in older adults: The Atherosclerosis Risk in Communities study
    Frances M Wang, Hannah Col, Fredrick Larbi Kwapong +14
    American Journal of HypertensionPeer-reviewedPublisher termsFull textEpidemiology & public healthPMC
  2. Optimizing Portal Venous Phase Acquisition Quality of Contrast-Enhanced CT in Oncology
    Amir Zemmouri, Marcus Talke, Marie Porte +14
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Automated Sleep Staging Performance Across Two Experimental Sleep Manipulation Protocols in Adolescents.
    João Paulo Lima Santos, London Evans, Rebecca L. Griffith +4
    medRxivPreprintAll rights reservedFull textEpidemiology & public healthmedRxivPMC
  4. Optimizing the contrast agent dose and image acquisition time for renal ultrasound localization microscopy
    Jing Zhang, Jiahao Han, Pingping Wang +3
    European Radiology ExperimentalPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMC
  5. A Comparative Study of Virtual Reality, Video, and Text-Based Training for Clinical Skills Acquisition in Health Science Students
    Daniel Rodríguez, Camilo Morales, Lisette Fuentes-Ugarte +4
    Medical Science EducatorPeer-reviewedLicence not statedFull textEpidemiology & public healthPMC
BibTeX
@article{dai2026optimizing,
  title = {{Optimizing IMPULSED Acquisition Protocols for Clinical 3T Scanners Through Bayesian Experimental Design}},
  author = {Yan Dai and Xun Jia and Todd Aguilera and Kai Jiang and Arely Perez Rodriguez and Isabelle Vanhaezebrouck and Jie Deng},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  month = sep,
  doi = {10.1002/mrm.70579},
  url = {https://doi.org/10.1002/mrm.70579},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Optimizing IMPULSED Acquisition Protocols for Clinical 3T Scanners Through Bayesian Experimental Design
AU  - Yan Dai
AU  - Xun Jia
AU  - Todd Aguilera
AU  - Kai Jiang
AU  - Arely Perez Rodriguez
AU  - Isabelle Vanhaezebrouck
AU  - Jie Deng
PY  - 2026
DA  - 2026/09/14
JO  - Magnetic Resonance in Medicine
DO  - 10.1002/mrm.70579
UR  - https://doi.org/10.1002/mrm.70579
AB  - Purpose: To optimize diffusion MRI acquisition protocols for Imaging Microstructural Parameters Using Limited Spectrally Edited Diffusion (IMPULSED) model at clinical 3T scanner using Bayesian experimental design, enabling accurate cellular‐scale parameter estimation under realistic scan time and scanner hardware constraints.  Methods: Expected Information Gain (EIG) was used as the optimization objective to maximize the information content of acquired measurements for IMPULSED model fitting. Bayesian optimization with Gaussian process surrogates efficiently searched the high‐dimensional acquisition parameter space, including pulse types (PGSE, OGSEn1, and OGSEn2), diffusion times, and b values. Optimized protocols were systematically evaluated against a heuristically designed baseline protocol through simulation studies assessing classification accuracy and parameter estimation performance across SNR levels of 5–40. Robustness to optimization assumptions was examined by varying prior distributions and assumed SNR. In vivo validation was performed using canine tumor data acquired at 3T.  Results: The optimized protocol eliminated OGSEn2 acquisitions, concentrated measurements at high b values (maximum 2000 s/mm2 for PGSE, 1220 s/mm2 for OGSEn1), employing concurrently optimized diffusion timing. Compared to the baseline protocol, the optimized design achieved superior classification accuracy for distinguishing cell populations and reduced parameter estimation error across biologically relevant parameter ranges at various SNRs. Performance advantages were consistent across diverse optimization scenarios, demonstrating robustness to prior knowledge and noise assumptions. In vivo parameter maps showed substantially improved quality and smoothness.  Conclusion: Bayesian optimization substantially improves IMPULSED acquisition design for clinical 3T scanners. This principled, algorithm‐agnostic framework enables accurate diffusion MRI cytometry under clinical constraints, with potential applications to tumor characterization and treatment monitoring.
SN  - 0740-3194
SN  - 1522-2594
ER  -