Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 18 min ago
Peer-reviewedCC BY-NC-SASurgical neurology international

A steerable microcatheter-stabilizer strategy for stent-assisted coiling of a wide-neck middle cerebral artery aneurysm with an acutely angulated incorporated branch.

  1. 1Department of Neurosurgery, Hakodate Neurosurgical Hospital, Hokkaido, Japan.

Abstract

Background

Wide-neck middle cerebral artery (MCA) aneurysms incorporating acutely angulated branches remain among the most technically challenging lesions in neuroendovascular therapy. Selective branch catheterization and subsequent catheter exchange may be difficult using conventional techniques.Methods

A 79-year-old man with an enlarging unruptured right MCA aneurysm underwent stent-assisted coil embolization. A 2.0-Fr SwiftNINJA (LEONIS Mova Selective, Merit Medical/SB-Kawasumi Laboratories, Kanagawa, Japan) steerable microcatheter was used to achieve distal access to the incorporated branch through active tip deflection and angle locking. After distal access had been secured, a Stabilizer device (The Medilizer Anchor Guiding Device; Bolt Medical, Carlsbad, CA, USA) was deployed to facilitate catheter exchange to a stent-delivery microcatheter.Results

The incorporated branch was successfully catheterized despite severe angulation. Distal anchoring with the Stabilizer device enabled safe catheter exchange, followed by successful deployment of a Neuroform Atlas stent (Stryker Neurovascular, Kalamazoo, MI, USA) and subsequent coil embolization. Complete aneurysm occlusion was achieved while preserving the incorporated branch, and no procedural complications occurred.Conclusion

This technical note describes a stepwise steerable microcatheter-stabilizer strategy that addresses two major procedural challenges - branch access and catheter exchange. The technique may represent a useful option for selected aneurysms requiring branch preservation and complex endovascular navigation.

Related

  1. Post-Detachment Displacement of a Woven EndoBridge (WEB) Device Managed via Microcatheter Manipulation: A Case Report.
    Kyoichi Seo, Yoji Kuramoto, Soichiro Abe +1
    Journal of neuroendovascular therapyPeer-reviewedCC BY-NCFull textNeurologyEurope PMC
  2. Role of Microcatheter Tip Position and Microguidewire Stiffness in Safe Neuroendovascular Navigation of Distal Vessels
    Keiko Fukuda, Kenichi Sakuta, Yoshiki Hanaoka +7
    AJNR: American Journal of NeuroradiologyPeer-reviewedCC BYFull textNeurologyPMC
  3. Transcatheter closure of ascending aortic pseudoaneurysm via steerable sheath assisted atrial septal occluder device delivery
    Nivedita Pant, Muzammil H. Musani
    Journal of Cardiology CasesPeer-reviewedLicence not statedFull textCardiovascular medicinePMC
  4. Feasibility of steerable sheath-guided left atrial appendage closure in challenging anatomy
    Sho Shiba, Masanori Yamamoto, Tatsuya Tsunaki +1
    Journal of Cardiology CasesPeer-reviewedLicence not statedFull textCardiovascular medicinePMC
  5. Transient Ischemic Attack Due to Delamination of a Steerable Guiding Sheath: A Potential Complication During Atrial Fibrillation Ablation
    Hafez Golzarian, Mohammad Khalil Kanjwal, Fayaz Hakim
    The Journal of innovations in cardiac rhythm managementPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
BibTeX
@article{yamazaki2026steerable,
  title = {{A steerable microcatheter-stabilizer strategy for stent-assisted coiling of a wide-neck middle cerebral artery aneurysm with an acutely angulated incorporated branch.}},
  author = {Takaaki Yamazaki and Hiroshi Moriwaki and Hidekazu Takada},
  journal = {Surgical neurology international},
  year = {2026},
  month = oct,
  doi = {10.25259/sni_708_2026},
  url = {https://europepmc.org/article/MED/42974525},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - A steerable microcatheter-stabilizer strategy for stent-assisted coiling of a wide-neck middle cerebral artery aneurysm with an acutely angulated incorporated branch.
AU  - Takaaki Yamazaki
AU  - Hiroshi Moriwaki
AU  - Hidekazu Takada
PY  - 2026
DA  - 2026/10/09
JO  - Surgical neurology international
DO  - 10.25259/sni_708_2026
UR  - https://europepmc.org/article/MED/42974525
AB  - Background  Wide-neck middle cerebral artery (MCA) aneurysms incorporating acutely angulated branches remain among the most technically challenging lesions in neuroendovascular therapy. Selective branch catheterization and subsequent catheter exchange may be difficult using conventional techniques.Methods  A 79-year-old man with an enlarging unruptured right MCA aneurysm underwent stent-assisted coil embolization. A 2.0-Fr SwiftNINJA (LEONIS Mova Selective, Merit Medical/SB-Kawasumi Laboratories, Kanagawa, Japan) steerable microcatheter was used to achieve distal access to the incorporated branch through active tip deflection and angle locking. After distal access had been secured, a Stabilizer device (The Medilizer Anchor Guiding Device; Bolt Medical, Carlsbad, CA, USA) was deployed to facilitate catheter exchange to a stent-delivery microcatheter.Results  The incorporated branch was successfully catheterized despite severe angulation. Distal anchoring with the Stabilizer device enabled safe catheter exchange, followed by successful deployment of a Neuroform Atlas stent (Stryker Neurovascular, Kalamazoo, MI, USA) and subsequent coil embolization. Complete aneurysm occlusion was achieved while preserving the incorporated branch, and no procedural complications occurred.Conclusion  This technical note describes a stepwise steerable microcatheter-stabilizer strategy that addresses two major procedural challenges - branch access and catheter exchange. The technique may represent a useful option for selected aneurysms requiring branch preservation and complex endovascular navigation.
SN  - 2229-5097
SN  - 2152-7806
ER  -