Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers

Abstract

T1-T2 correlation MRI has strong potential to quantify microstructural compartments without imposing a biological model. Traditionally, full T1-T2 spectra per voxel are reconstructed with an ill-conditioned and time-consuming Inverse Laplace Transform. We propose to view this challenge as an object detection task: A Detection Transformer (DETR) takes 64 TI/TE signals and directly predicts a set of compartments specified by T1, T2, and signal fraction. We achieve a mean average precision mAP@10 of 76.8% on simulated data, outperforming both our previous model design (53.8%) and regularized NNLS (66.1%). We show that our DETR approach outperforms NNLS in almost every setting across compartment count, compartmental signal fraction, and SNR. Reconstruction is orders of magnitude faster than NNLS. The results are fully reproducible from our public code: github.com/SebastianEndtTHI/t1t2-detr

Related

  1. Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers
    Sebastian Endt, Marcus Wirth, Johannes Reinhold Schlund +1
    arXivPreprintCC BY-NC-SA 4.0Full textBiological & medical physicsarXiv
  2. Transformers with Physics-Informed Encodings and Simulation-Based Inference for Robust Detection of Eccentric Binary Black Holes in Pulsar Timing Array Data
    Subhajit Dandapat, Alvin J. K. Chua
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsGravitation & general relativityarXiv
  3. Generalized Glauber theorem for dark-matter axion and graviton detection
    Jakub Bręczewski, Ayuki Kamada, Akira Miyazaki
    HALPreprintLicence not statedGravitation & general relativityHigh-energy & particle physicsHAL
  4. Granger causality detection with Kolmogorov-Arnold networks
    Hongyu Lin, Mohan Ren, Paolo Barucca +1
    Physical Review ResearchPeer-reviewedPublisher termsAtomic, molecular & optical physicsCrossref
  5. Optical detection and manipulation of pseudospin orders in Wigner crystals
    Yichen Dong, Eugene Demler, Zhiyuan Sun
    Physical Review ResearchPeer-reviewedPublisher termsAtomic, molecular & optical physicsCrossref
BibTeX
@misc{endt2026detection,
  title = {{Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers}},
  author = {Sebastian Endt and Fatih Özkan and Marion I. Menzel},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.01790},
  eprint = {2611.01790},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.01790},
  note = {CC BY-NC-SA 4.0},
}
RIS
TY  - UNPB
TI  - Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers
AU  - Sebastian Endt
AU  - Fatih Özkan
AU  - Marion I. Menzel
PY  - 2026
DA  - 2026/11/01
PB  - arXiv
DO  - 10.48550/arxiv.2611.01790
UR  - https://arxiv.org/abs/2611.01790
AB  - T1-T2 correlation MRI has strong potential to quantify microstructural compartments without imposing a biological model. Traditionally, full T1-T2 spectra per voxel are reconstructed with an ill-conditioned and time-consuming Inverse Laplace Transform. We propose to view this challenge as an object detection task: A Detection Transformer (DETR) takes 64 TI/TE signals and directly predicts a set of compartments specified by T1, T2, and signal fraction. We achieve a mean average precision mAP@10 of 76.8% on simulated data, outperforming both our previous model design (53.8%) and regularized NNLS (66.1%). We show that our DETR approach outperforms NNLS in almost every setting across compartment count, compartmental signal fraction, and SNR. Reconstruction is orders of magnitude faster than NNLS. The results are fully reproducible from our public code: github.com/SebastianEndtTHI/t1t2-detr
ER  -