Translation and validation of the TEAM-NL instrument for assessing interprofessional team performance in simulation-based resuscitation training
12 affiliations
- 1Department of Anaesthesiology, Universitair Ziekenhuis Brussel, Brussels, Belgium
- 2School of Health Professions Education (SHE), Maastricht University, Maastricht, the Netherlands
- 3Department of Anaesthesiology and Pain Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands
- 4Department of Simulation in Healthcare, Maastricht University Medical Centre, Maastricht, the Netherlands
- 5Quality and Training Time, Houten, the Netherlands
- 6Department of Intensive Care Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands
- 7Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, the Netherlands
- 8Care and Public Health Research Institute (Caphri), Maastricht University, Maastricht, the Netherlands
- 9Board of Directors, Albert Schweitzer Hospital, Dordrecht, the Netherlands
- 10Department of Educational Development and Research, Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands
- 11Academy for Postgraduate Medical Training, Maastricht University Medical Centre, Maastricht, the Netherlands
- 12Cooper Consultancy, Cowes, Victoria, Australia
Abstract
Background: Effective interprofessional teamwork is essential for successful resuscitation care. The Team Emergency Assessment Measure (TEAM) is widely used to assess emergency team performance; however, a validated Dutch version is lacking. This study aimed to translate and validate a Dutch version of the TEAM (TEAM-NL) for simulation-based resuscitation training.
Methods: A structured cross-cultural adaptation was performed, including forward–backward translation, developer review and expert review. Instructors used the TEAM-NL during Advanced Life Support courses at two Dutch training centres, rating each participant group in two simulation scenarios. Internal consistency, inter-rater reliability, convergent validity, change in scores between scenarios, acceptability and score distribution were assessed.
Results: A total of 52 participant groups were observed, yielding 104 observed team performances and 299 instructor ratings. The mean total score (range 0–44) was 32.1 (SD 6.9). Internal consistency was high (Cronbach’s α = 0.93). Inter-rater reliability was moderate for two raters (ICC(1,2) = 0.68, 95% CI 0.53–0.79) and good for three raters (ICC(1,3) = 0.78, 95% CI 0.69–0.85). The total score correlated strongly with the global performance rating (r = 0.86, p < 0.001). Scores were higher in the second scenario (mean difference 4.3, 95% CI 2.2–6.4; dz = 0.57). Missing data were minimal (0–2.7% per item). No floor effects were observed; ceiling effects were present for all items (19.4–36.1%).
Conclusion: The TEAM-NL showed high internal consistency, convergent validity and acceptability for instructor-based assessment of team performance during simulation-based resuscitation training. Inter-rater reliability was moderate for two raters and good when the ratings of three instructors were averaged.
Related
- Editorial: Measuring vaccination perception, confidence, and uptake: advancing instrument development and validation
- Development and Validation of the Food Expectation Questionnaire (FEX‐Q): An Image‐Based Instrument to Assess Food‐Related Perceptions and Symptom Expectations
- Development and content validation of a hybrid interprofessional course for first-year health professions students.
- Autistic Adults' Perceptions of the Adequacy of their Supports and Disability-Related Information: Instrument Validation & Preliminary Correlates
- Temporal Validation and Simplification of Mortality Prediction for Perioperative Cardiopulmonary Resuscitation
BibTeX
@article{marynen2026translation,
title = {{Translation and validation of the TEAM-NL instrument for assessing interprofessional team performance in simulation-based resuscitation training}},
author = {Frederik Marynen and Lars Mommers and Dennie Wulterkens and Thom Bormans and Bas C.T. van Bussel and Iwan C.C. van der Horst and Daniëlle Verstegen and Diana Dolmans and Walther N.K.A. van Mook and Simon Cooper},
journal = {Resuscitation Plus},
year = {2026},
month = oct,
doi = {10.1016/j.resplu.2026.101535},
url = {https://doi.org/10.1016/j.resplu.2026.101535},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Translation and validation of the TEAM-NL instrument for assessing interprofessional team performance in simulation-based resuscitation training
AU - Frederik Marynen
AU - Lars Mommers
AU - Dennie Wulterkens
AU - Thom Bormans
AU - Bas C.T. van Bussel
AU - Iwan C.C. van der Horst
AU - Daniëlle Verstegen
AU - Diana Dolmans
AU - Walther N.K.A. van Mook
AU - Simon Cooper
PY - 2026
DA - 2026/10/20
JO - Resuscitation Plus
DO - 10.1016/j.resplu.2026.101535
UR - https://doi.org/10.1016/j.resplu.2026.101535
AB - Background: Effective interprofessional teamwork is essential for successful resuscitation care. The Team Emergency Assessment Measure (TEAM) is widely used to assess emergency team performance; however, a validated Dutch version is lacking. This study aimed to translate and validate a Dutch version of the TEAM (TEAM-NL) for simulation-based resuscitation training. Methods: A structured cross-cultural adaptation was performed, including forward–backward translation, developer review and expert review. Instructors used the TEAM-NL during Advanced Life Support courses at two Dutch training centres, rating each participant group in two simulation scenarios. Internal consistency, inter-rater reliability, convergent validity, change in scores between scenarios, acceptability and score distribution were assessed. Results: A total of 52 participant groups were observed, yielding 104 observed team performances and 299 instructor ratings. The mean total score (range 0–44) was 32.1 (SD 6.9). Internal consistency was high (Cronbach’s α = 0.93). Inter-rater reliability was moderate for two raters (ICC(1,2) = 0.68, 95% CI 0.53–0.79) and good for three raters (ICC(1,3) = 0.78, 95% CI 0.69–0.85). The total score correlated strongly with the global performance rating (r = 0.86, p < 0.001). Scores were higher in the second scenario (mean difference 4.3, 95% CI 2.2–6.4; dz = 0.57). Missing data were minimal (0–2.7% per item). No floor effects were observed; ceiling effects were present for all items (19.4–36.1%). Conclusion: The TEAM-NL showed high internal consistency, convergent validity and acceptability for instructor-based assessment of team performance during simulation-based resuscitation training. Inter-rater reliability was moderate for two raters and good when the ratings of three instructors were averaged.
SN - 2666-5204
ER -