uGMRT Polarization Observations with Walsh Modulation
Abstract
In this report, we discuss the performance of the Walsh phase-switching scheme for Band 4 (550-750 MHz) polarimetric observations with the upgraded GMRT (uGMRT). We have carried out test observations with the Walsh modulation enabled and disabled, using the polarized calibrator 3C138 as the target and unpolarized calibrator 3C147 for amplitude, phase and leakage calibration. The two Walsh datasets (ON & OFF) were processed using identical flagging, calibration, and imaging procedures. The Walsh ON data showed smoother leakage solutions and lower residual scatter in the Stokes I, Q, U data. The Walsh scheme also suppressed a fraction of anomalous data at the correlation stage, reducing the amount of subsequent flagging required during data processing. The final self-calibrated images obtained with Walsh ON showed improved image fidelity, lower r.m.s. noise, and reduced error in the fractional polarization of 3C138. However, the possibility that the Walsh scheme itself introduces spurious frequency-dependent structure into the Stokes Q and U signals remains and warrants closer investigation. Overall, these results demonstrate the potential of Walsh phase switching to mitigate instrumental cross-talk and improve the reliability of polarimetric measurements with the uGMRT.
Related
- Calibration requirements for Epoch of Reionization 21-cm signal observations - V. Bias and variance in the cylindrical power spectrum from uGMRT Band 3 observations of the ELAIS-N1 field
- Polarization Observations of NGC 315 with FAST
- Polarization Observations of a sample of Excited OH masers
- Polarization Observations of a Sample of Excited OH Masers
- A Pipeline for the AI-Assisted Analysis of Imaging X-ray Polarimetry Explorer Observations of Black Hole X-ray Binaries and Limits on Their Polarization Variability
BibTeX
@misc{ghosh2026ugmrt,
title = {{uGMRT Polarization Observations with Walsh Modulation}},
author = {Salmoli Ghosh and Preeti Kharb and Sandeep Chaudhari and Surajit Mondal},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.20744},
eprint = {2610.20744},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.20744},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - uGMRT Polarization Observations with Walsh Modulation
AU - Salmoli Ghosh
AU - Preeti Kharb
AU - Sandeep Chaudhari
AU - Surajit Mondal
PY - 2026
DA - 2026/10/14
PB - arXiv
DO - 10.48550/arxiv.2610.20744
UR - https://arxiv.org/abs/2610.20744
AB - In this report, we discuss the performance of the Walsh phase-switching scheme for Band 4 (550-750 MHz) polarimetric observations with the upgraded GMRT (uGMRT). We have carried out test observations with the Walsh modulation enabled and disabled, using the polarized calibrator 3C138 as the target and unpolarized calibrator 3C147 for amplitude, phase and leakage calibration. The two Walsh datasets (ON & OFF) were processed using identical flagging, calibration, and imaging procedures. The Walsh ON data showed smoother leakage solutions and lower residual scatter in the Stokes I, Q, U data. The Walsh scheme also suppressed a fraction of anomalous data at the correlation stage, reducing the amount of subsequent flagging required during data processing. The final self-calibrated images obtained with Walsh ON showed improved image fidelity, lower r.m.s. noise, and reduced error in the fractional polarization of 3C138. However, the possibility that the Walsh scheme itself introduces spurious frequency-dependent structure into the Stokes Q and U signals remains and warrants closer investigation. Overall, these results demonstrate the potential of Walsh phase switching to mitigate instrumental cross-talk and improve the reliability of polarimetric measurements with the uGMRT.
ER -